Detection of the electromechanical delay and its components during voluntary isometric contraction of the quadriceps femoris muscle

被引:72
作者
Begovic, Haris [1 ]
Zhou, Guang-Quan [1 ]
Li, Tianjie [1 ]
Wang, Yi [1 ]
Zheng, Yong-Ping [1 ]
机构
[1] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Fac Engn, Kowloon, Hong Kong, Peoples R China
关键词
electromechanical delay; excitation-contraction coupling; series elastic components; contractile components; rectus femoris muscle; transient ultrasound; HUMAN SKELETAL-MUSCLE; FRAME RATE ULTRASOUND; RESPONSE-TIMES; STIMULATION; EXTENSORS; FATIGUE;
D O I
10.3389/fphys.2014.00494
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Electromechanical delay (EMD) was described as a time elapsed between first trigger and force output. Various results have been reported based on the measurement method with observed inconsistent results when the trigger is elicited by voluntary contraction. However, mechanomyographic (MMG) sensor placed far away on the skin from the contracting muscle was used to detect muscle fiber motion and excitation-contraction (EC) coupling which may give unreliable results. On this basis, the purpose of this study was to detect EMD during active muscle contraction whilst introducing an ultrafast ultrasound (US) method to detect muscle fiber motion from a certain depth of the muscle. Time delays between onsets of EMG-MMG, EMG-US, MMG-FORCE, US-FORCE, and EMG-FORCE were calculated as 20.5 +/- 4.73, 28.63 +/- 6.31, 19.21 +/- 6.79, 30.52 +/- 8.85, and 49.73 +/- 6.99 ms, respectively. Intrarater correlation coefficient (ICC) was higher than MMG when ultrafast US was used for detecton of the At EMG-US and Delta t US-FORCE, ICC values of 0.75 and 0.70, respectively. Synchronization of the ultrafast ultrasound with EMG and FORCE sensors can reveal reliable and clinically useful results related to the EMD and its components when muscle is voluntarily contracted. With ultrafast US, we detect onset from the certain depth of the muscle excluding the tissues above the muscle acting as a low-pass filter which can lead to inaccurate time detection about the onset of the contracting muscle fibers. With this non-invasive technique, understanding of the muscle dynamics can be facilitated.
引用
收藏
页数:8
相关论文
共 35 条
[1]   An examination of cross-talk among surface mechanomyographic signals from the superficial quadriceps femoris muscles during isometric muscle actions [J].
Beck, Travis W. ;
DeFreitas, Jason M. ;
Stock, Matt S. .
HUMAN MOVEMENT SCIENCE, 2010, 29 (02) :165-171
[2]  
BELL DG, 1986, MED SCI SPORT EXER, V18, P31
[3]  
Blackburn J Troy, 2009, J Electromyogr Kinesiol, V19, pe362, DOI 10.1016/j.jelekin.2008.08.005
[4]   Electromyographic and mechanomyographic responses across repeated maximal isometric and concentric muscle actions of the leg extensors [J].
Camic, Clayton L. ;
Housh, Terry J. ;
Zuniga, Jorge M. ;
Hendrix, C. Russell ;
Bergstrom, Haley C. ;
Traylor, Daniel A. ;
Schmidt, Richard J. ;
Johnson, Glen O. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2013, 23 (02) :342-348
[5]   ELECTRO-MECHANICAL DELAY IN HUMAN SKELETAL-MUSCLE UNDER CONCENTRIC AND ECCENTRIC CONTRACTIONS [J].
CAVANAGH, PR ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1979, 42 (03) :159-163
[6]   Effects of temperature and fatigue on the electromechanical delay components [J].
Ce, Emiliano ;
Rampichini, Susanna ;
Agnello, Luca ;
Limonta, Eloisa ;
Veicsteinas, Arsenio ;
Esposito, Fabio .
MUSCLE & NERVE, 2013, 47 (04) :566-576
[7]   Electromechanical Delay of the Vastus Medialis Obliquus and Vastus Lateralis in Individuals With Patellofemoral Pain Syndrome [J].
Chen, Han-Yu ;
Chien, Chia-Chen ;
Wu, Shyi-Kuen ;
Liau, Jiann-Jong ;
Jan, Mei-Hwa .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2012, 42 (09) :791-796
[8]   Ultrafast imaging of in vivo muscle contraction using ultrasound [J].
Deffieux, Thomas ;
Gennisson, Jean-Luc ;
Tanter, Mickael ;
Fink, Mathias ;
Nordez, Antoine .
APPLIED PHYSICS LETTERS, 2006, 89 (18)
[9]   Assessment of the mechanical properties of the musculoskeletal system using 2-D and 3-D very high frame rate ultrasound [J].
Deffieux, Thomas ;
Gennisson, Jean-Luc ;
Tanter, Mickael ;
Fink, Mathias .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (10) :2177-2190
[10]   The influence of loading intensity on muscle-tendon unit behavior during maximal knee extensor stretch shortening cycle exercise [J].
Earp, Jacob E. ;
Newton, Robert U. ;
Cormie, Prue ;
Blazevich, Anthony J. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2014, 114 (01) :59-69