An iterative image reconstruction algorithm combined with forward and backward diffusion filtering for in-line X-ray phase-contrast computed tomography

被引:7
作者
Zhao, Yuqing [1 ]
Sun, Mengyu [1 ]
Ji, Dongjiang [2 ]
Cong, Changhong [3 ]
Lv, Wenjuan [1 ]
Zhao, Qi [1 ]
Qin, Lili [1 ]
Jian, Jianbo [4 ]
Chen, Xiaodong [5 ]
Hu, Chunhong [1 ]
机构
[1] Tianjin Med Univ, Coll Biomed Engn, Tianjin 300070, Peoples R China
[2] Tianjin Univ Technol & Educ, Sch Sci, Tianjin 300222, Peoples R China
[3] Tianjin Med Univ, Dent Hosp, Tianjin 300070, Peoples R China
[4] Tianjin Med Univ, Gen Hosp, Radiat Oncol Dept, Tianjin 300070, Peoples R China
[5] Tianjin Univ, Minist Educ, Key Lab Optoelect Informat Technol, Tianjin 300072, Peoples R China
来源
JOURNAL OF SYNCHROTRON RADIATION | 2018年 / 25卷
基金
中国国家自然科学基金;
关键词
in-line X-ray phase-contrast computed tomography; simultaneous algebraic reconstruction technique; forward and backward diffusion filtering; few-view projections; SYNCHROTRON-RADIATION; CT RECONSTRUCTION; HIGH-ENERGY; RETRIEVAL; MICROVASCULATURE; REGULARIZATION; VISUALIZATION; FORMULAS; FIBROSIS; OBJECT;
D O I
10.1107/S1600577518009219
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In-line X-ray phase-contrast computed tomography (IL-PCCT) can reveal fine inner structures for low-Z materials (e.g. biological soft tissues), and shows high potential to become clinically applicable. Typically, IL-PCCT utilizes filtered back-projection (FBP) as the standard reconstruction algorithm. However, the FBP algorithm requires a large amount of projection data, and subsequently a large radiation dose is needed to reconstruct a high-quality image, which hampers its clinical application in IL-PCCT. In this study, an iterative reconstruction algorithm for IL-PCCT was proposed by combining the simultaneous algebraic reconstruction technique (SART) with eight-neighbour forward and backward (FAB8) diffusion filtering, and the reconstruction was performed using the Shepp-Logan phantom simulation and a real synchrotron IL-PCCT experiment. The results showed that the proposed algorithm was able to produce high-quality computed tomography images from few-view projections while improving the convergence rate of the computed tomography reconstruction, indicating that the proposed algorithm is an effective method of dose reduction for IL-PCCT.
引用
收藏
页码:1450 / 1459
页数:10
相关论文
共 45 条
  • [1] Baumann M, 2014, THESIS, P6
  • [2] Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior
    Bian, Zhaoying
    Zeng, Dong
    Zhang, Zhang
    Gong, Changfei
    Tian, Xiumei
    Yan, Gang
    Huang, Jing
    Guo, Hong
    Chen, Bo
    Zhang, Jing
    Feng, Qianjin
    Chen, Wufan
    Ma, Jianhua
    [J]. MEDICAL PHYSICS, 2017, 44 (09) : E188 - E201
  • [3] A Novel and Sensitive Approach for the Evaluation of Liver Ischemia-Reperfusion Injury After Liver Transplantation
    Brandlhuber, Martina
    Armbruster, Marco
    Zupanc, Blaz
    Coan, Paola
    Brun, Emmanuel
    Sommer, Wieland
    Rentsch, Markus
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (03) : 170 - 176
  • [4] Bravin A., 2012, PHYS MED BIOL, V57, P2931
  • [5] Theory of quantitative phase-contrast computed tomography
    Bronnikov, AV
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (03) : 472 - 480
  • [6] Reconstruction formulas in phase-contrast tomography
    Bronnikov, AV
    [J]. OPTICS COMMUNICATIONS, 1999, 171 (4-6) : 239 - 244
  • [7] Three Dimensional Quantification of Microarchitecture and Vessel Regeneration by Synchrotron Radiation Microcomputed Tomography in a Rat Model of Spinal Cord Injury
    Cao, Yong
    Zhou, Yuan
    Ni, Shuangfei
    Wu, Tianding
    Li, Ping
    Liao, Shenghui
    Hu, Jianzhong
    Lu, Hongbin
    [J]. JOURNAL OF NEUROTRAUMA, 2017, 34 (06) : 1187 - 1199
  • [8] Comparison of single distance phase retrieval algorithms by considering different object composition and the effect of statistical and structural noise
    Chen, R. C.
    Rigon, L.
    Longo, R.
    [J]. OPTICS EXPRESS, 2013, 21 (06): : 7384 - 7399
  • [9] Quantitative 3D refractive index decrement reconstruction using single-distance phase-contrast tomography data
    Chen, R. C.
    Rigon, L.
    Longo, R.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (49)
  • [10] PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
    Chen, Rong-Chang
    Dreossi, Diego
    Mancini, Lucia
    Menk, Ralf
    Rigon, Luigi
    Xiao, Ti-Qiao
    Longo, Renata
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 836 - 845