Low-density gel dosimeter for measurement of the electron return effect in an MR-linac

被引:16
|
作者
McDonald, Brigid A. [1 ,2 ]
Lee, Hannah J. [1 ,3 ]
Ibbott, Geoffrey S. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Med Phys Program, UTHlth Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Allegheny Hlth Network, Dept Radiat Oncol, Pittsburgh, PA USA
关键词
MR image-guided radiation therapy; MR-linac; gel dosimetry; electron return effect; MAGNETIC-FIELD; COMPUTED-TOMOGRAPHY; DOSE RESOLUTION; RADIOTHERAPY; OPTIMIZATION; ACCELERATOR; IMPACT;
D O I
10.1088/1361-6560/ab4321
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
.Radiation therapy in the presence of a strong magnetic field is known to cause regions of enhanced and reduced dose at interfaces of materials with varying densities, in a phenomenon known as the electron return effect (ERE). In this study, a novel low-density gel dosimeter was developed to simulate lung tissue and was used to measure the ERE at the lung-soft tissue interface. Low-density gel dosimeters were developed with Fricke xylenol orange gelatin (FXG) and ferrous oxide xylenol orange (FOX) gels mixed with polystyrene foam beads of various sizes. The gels were characterized based on CT number, MR signal intensity, and uniformity. All low-density gels had CT numbers roughly equivalent to lung tissue. The optimal lung-equivalent gel formulation was determined to be FXG with <1 mm polystyrene beads due to the higher signal intensity of FXG compared to FOX and the higher uniformity with the small beads. Dose response curves were generated for the optimal low-density gel and conventional FXG. The change in spin-lattice relaxation rate (R1) before and after irradiation was linear with dose for both gels. Next, phantoms consisting of concentric cylinders with low-density and conventional FXG were created to simulate the lung-soft tissue interface. The phantoms were irradiated in a conventional linear accelerator (linac) and in a linac combined with a 1.5 T magnetic resonance imaging (MRI) unit (MR-linac) to measure the effects of the magnetic field on the dose distribution. Hot and cold spots were observed in the dose distribution at the boundaries between the gels for the phantom irradiated in the MR-linac but not the conventional linac, consistent with the ERE
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Design of a low-density SNP chip for the main Australian sheep breeds and its effect on imputation and genomic prediction accuracy
    Bolormaa, S.
    Gore, K.
    van der Werf, J. H. J.
    Hayes, B. J.
    Daetwyler, H. D.
    ANIMAL GENETICS, 2015, 46 (05) : 544 - 556
  • [42] Measurement of selected polychlorinated biphenyls (PCBs) in water via ultrasound assisted emulsification-microextraction (USAEME) using low-density organic solvents
    Yurdakok-Dikmen, Begum
    Kuzukiran, Ozgur
    Filazi, Ayhan
    Kara, Erdem
    JOURNAL OF WATER AND HEALTH, 2016, 14 (02) : 214 - 222
  • [43] Low-Density Polyethylene Plastic Waste to Liquid Fuel Using Pyrolysis Method: an Effect of Temperatures on the Oil Yields Physicochemical Properties
    Wijayanti, Widya
    Musyaroh
    Sasongko, Mega Nur
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2022, 10 (03):
  • [44] Effect of pharmacist interventions on reducing low-density lipoprotein cholesterol (LDL-C) levels: A systematic review and meta-analysis
    Dixon, Dave L.
    Khaddage, Sarah
    Bhagat, Shailja
    Koenig, Rachel A.
    Salgado, Teresa M.
    Baker, William L.
    JOURNAL OF CLINICAL LIPIDOLOGY, 2020, 14 (03) : 282 - +
  • [45] Effect of magnetic field on the thermophysical properties of low-density ferrofluid with disk-shaped MgFe2O4 nanoparticles
    Ajith, K.
    Pillai, Archana Sumohan
    Enoch, I. V. Muthu Vijayan
    Solomon, A. Brusly
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2021, 613
  • [46] Structural and superconducting properties of low-density Bi(Pb)-2223 superconductor: Effect of Eu2O3 nanoparticles addition
    Nurbaisyatul, E. S.
    Azhan, H.
    Ibrahim, N.
    Saipuddin, S. F.
    CRYOGENICS, 2021, 119 (119)
  • [47] Evaluating the effect of low-density inhomogeneities: A comparative study of lithium fluoride detectors, radiochromic films, and collapsed cone algorithm in 6 MV photon beams
    da Silveira, Anna Luiza Fraga
    Araujo, Fernanda da Silva Goncalves
    Calheiro, Daniel Silva
    Tavares e Silva, Andre Luiz
    Goncalves, Bruno Rodrigues
    Castro, Andres Lima de Souza
    Nolasco, Arnie Verde
    Meira-Belo, Luiz Claudio
    APPLIED RADIATION AND ISOTOPES, 2023, 202
  • [48] Effect of hot rolling reduction and annealing treatment on grain boundary character distribution in austenitic low-density Fe-Mn-Al-C-Cr steel
    Liu, Jinxu
    Wu, Huibin
    Yang, Shanwu
    Yu, Xinpan
    Ding, Chao
    MATERIALS LETTERS, 2021, 285
  • [49] Effect of fenofibrate in 1113 patients at low-density lipoprotein cholesterol goal but high triglyceride levels: Real-world results and factors associated with triglyceride reduction
    Woo, Yeongmin
    Shin, Jeong-soo
    Shim, Chi-Young
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Park, Sungha
    Chang, Hyuk-Jae
    Hong, Geu-Ru
    Ko, Young-Guk
    Kang, Seok-Min
    Choi, Donghoon
    Ha, Jong-Won
    Hong, Myeong-Ki
    Jang, Yangsoo
    Lee, Sang-Hak
    PLOS ONE, 2018, 13 (10):
  • [50] Geant4 Monte Carlo investigation of the magnetic field effect on dose distributions in low-density regions in magnetic resonance image-guided radiation therapy
    Yano, Masayuki
    Araki, Fujio
    Ohno, Takeshi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 17 - 34