Development of a flexible film electromagnetic acoustic transducer for nondestructive testing

被引:26
作者
Pei, Cuixiang [1 ]
Xiao, Pan [1 ]
Zhao, Siqi [1 ]
Chen, Zhenmao [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Strength & Vibrat Mech Struct, Shanxi Engn Res Ctr NDT & Struct Integr Evaluat, Xian 710049, Peoples R China
关键词
Electromagnetic acoustic transducer; Flexible film; Magnetic coil; Non-destructive testing; SIMULATION; STEEL; COIL;
D O I
10.1016/j.sna.2017.03.004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromagnetic acoustic transducers (EMATs) have been widely applied for non-contact and coupling free ultrasonic testing (UT) of metal structures. In this paper, a new EMAT of flexible film type with thickness less than 1 mm, which uses dual coil configuration but without a permanent magnet, is proposed for both ultrasound generation and detection. Instead of using permanent magnet, a planar magnetic coil fed with a rectangular-pulsed current with duration about 1.5 ms is used to generate magnetic flux in the test objects. The obvious advantages of the proposed flexible film EMAT are that it can be easily applied for non-contact and coupling-free UT of curved structures and objects with very narrow inspection space. Pulsed electromagnetic fields and the induced ultrasound waves are studied by simulation and experiment. The results show that the flexible film EMAT has a good performance for generating and receiving ultrasonic waves and can be easily applied for testing of curved structural component with narrow inspection space. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 17 条
[1]   High temperature thickness measurements of stainless steel and low carbon steel using electromagnetic acoustic transducers [J].
Burrows, S. E. ;
Fan, Y. ;
Dixon, S. .
NDT & E INTERNATIONAL, 2014, 68 :73-77
[2]   Non-contact ultrasonic techniques [J].
Green, RE .
ULTRASONICS, 2004, 42 (1-9) :9-16
[3]   Initial tests for designing a high temperature EMAT with pulsed electromagnet [J].
Hernandez-Valle, Francisco ;
Dixon, Steve .
NDT & E INTERNATIONAL, 2010, 43 (02) :171-175
[4]  
Huang H., 1998, ELECTROMAGNETIC NOND, V2, P313
[5]   Study on the lift-off effect of EMAT [J].
Huang, Songling ;
Zhao, Wei ;
Zhang, Yongsheng ;
Wang, Shen .
SENSORS AND ACTUATORS A-PHYSICAL, 2009, 153 (02) :218-221
[6]   Coupling mechanism of an EMAT [J].
Jian, X. ;
Dixon, S. ;
Edwards, R. S. ;
Morrison, J. .
ULTRASONICS, 2006, 44 :E653-E656
[7]  
MacLauchlan D., 2004, P 16 WORLD C NDT, P1154
[8]  
MAXFIELD BW, 1983, MATER EVAL, V41, P1399
[9]   Field dependence of coupling efficiency between electromagnetic field and ultrasonic bulk waves [J].
Ogi, H .
JOURNAL OF APPLIED PHYSICS, 1997, 82 (08) :3940-3949
[10]   New design of electromagnetic acoustic transducer for precise determination of defect [J].
Ohtsuka, Y. ;
Yoshimura, T. ;
Ueda, Y. .
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, :1609-1612