Homogeneity study of candidate reference material (contaminated soil) based on determination of selected metals, PCBs and PAHs

被引:11
作者
Rutkowska, Malgorzata [1 ]
Kochanska, Kinga [1 ]
Kandel, Lekhanath [1 ,2 ]
Bajger-Nowak, Gabriela [1 ]
Slominska, Marta [1 ]
Marc, Mariusz [1 ]
Chojnacka, Katarzyna [3 ]
Polkowska-Motrenko, Halina [4 ]
Zabiegala, Bozena [1 ]
Namiesnik, Jacek [1 ]
Konieczka, Piotr [1 ]
机构
[1] Gdansk Univ Technol, Dept Analyt Chem, Fac Chem, 11-12 G Narutowicza St, PL-80233 Gdansk, Poland
[2] Govt Nepal, Minist Ind, NBSM, POB 985, Kathmandu, Nepal
[3] Wroclaw Univ Technol, Inst Inorgan Technol & Mineral Fertilizers, 25 Smoluchowskiego St, PL-50373 Wroclaw, Poland
[4] Inst Nucl Chem & Technol, 16 Dorodna St, PL-03195 Warsaw, Poland
关键词
Reference material; Certified reference material; Homogeneity; Contaminated soil; CERTIFIED REFERENCE MATERIALS; CERTIFICATION; QUALITY; CRMS;
D O I
10.1016/j.measurement.2018.06.021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Reference materials (RMs) are an indispensable part of QA/QC system and have played a critical role in the continual expansion of analytical capabilities of the analytical laboratories. The homogeneity study of the candidate for reference material is essential for the quality of reference material (certified reference material) used in quality assurance activities. The homogeneity study of candidate for reference materials of contaminated soil collected from a plot situated near the chemical factory "Rokita" in Brzeg Dolny (Silesian Region of Poland) for total metal content of Mg, Fe, Zn, Hg and analytes from a group of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) was carried out. The experimental design and study by using one way ANOVA showed no significant difference within and between bottle homogeneity and the material was found homogeneous. Total expanded uncertainty (k = 2) due to heterogeneity for all four metals and analytes from a group of PCBs and PAHs was determined within the range of 5-15%. The candidate for reference material of fortified soil was found to be homogeneous up to the minimum sample size of 100 mg for total Hg, 500 mg for Mg, Fe, Zn and 1 g from a group of PCBs and PAHs, and thus is suitable for certification.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 24 条
  • [1] [Anonymous], 2015, ISO GUID 33 REF GOOD
  • [2] [Anonymous], 2017, 17025 ISOIEC
  • [3] [Anonymous], 2015, ISO GUID 31 REF MAT
  • [4] [Anonymous], 2017, REFERENCE MAT GUIDAN
  • [5] [Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • [6] Assessment of potential health risk for inhabitants living near a former lead smelter. Part 1: metal concentrations in soils, agricultural crops, and homegrown vegetables
    Douay, Francis
    Pelfrene, Aurelie
    Planque, Julie
    Fourrier, Herve
    Richard, Antoine
    Roussel, Helene
    Girondelot, Bertrand
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (05) : 3665 - 3680
  • [7] Preparation and preliminary certification of two new Polish CRMs for inorganic trace analysis
    Dybczynski, R
    Danko, B
    Kulisa, K
    Maleszewska, E
    Polkowska-Motrenko, H
    Samczynski, Z
    Szopa, Z
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 259 (03) : 409 - 413
  • [8] Some difficult problems still existing in the preparation and certification of CRMs
    Dybczynski, R
    Danko, B
    Polkowska-Motrenko, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (2-3): : 126 - 130
  • [9] CERTIFICATION OF THE CONTENTS OF CADMIUM, COPPER, MANGANESE, MERCURY, LEAD AND ZINC IN 2 PLANT MATERIALS OF AQUATIC ORIGIN AND IN OLIVE LEAVES
    GRIEPINK, B
    MUNTAU, H
    COLINET, E
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 315 (03): : 193 - 196
  • [10] ISO 17034, 2016, GEN REQUIREMENTS COM