Implementing SARS-CoV-2 Rapid Antigen Testing in the Emergency Ward of a Swiss University Hospital: The INCREASE Study

被引:44
作者
Caruana, Giorgia [1 ,2 ]
Croxatto, Antony [1 ,2 ]
Kampouri, Eleftheria [2 ,3 ,4 ]
Kritikos, Antonios [1 ,2 ]
Opota, Onya [1 ,2 ]
Foerster, Maryline [5 ]
Brouillet, Rene [1 ,2 ]
Senn, Laurence [2 ,3 ,4 ]
Lienhard, Reto [6 ]
Egli, Adrian [7 ,8 ]
Pantaleo, Giuseppe [9 ]
Carron, Pierre-Nicolas [5 ]
Greub, Gilbert [1 ,2 ,4 ]
机构
[1] Lausanne Univ Hosp, Inst Microbiol, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne, CH-1011 Lausanne, Switzerland
[3] Lausanne Univ Hosp, Serv Hosp Prevent Med, CH-1011 Lausanne, Switzerland
[4] Lausanne Univ Hosp, Serv Infect Dis, CH-1011 Lausanne, Switzerland
[5] Lausanne Univ Hosp, Emergency Dept, CH-1011 Lausanne, Switzerland
[6] ADMed Microbiol Lab, CH-2300 La Chaux De Fonds, Switzerland
[7] Univ Hosp Basel, Clin Bacteriol & Mycol, CH-4001 Basel, Switzerland
[8] Univ Basel, Dept Biomed, Appl Microbiol Res, CH-4031 Basel, Switzerland
[9] Univ Hosp Lausanne, Inst Immunol, CH-1011 Lausanne, Switzerland
关键词
SARS-CoV-2; COVID-19 diagnostic testing; rapid antigen test; health plan implementation; nucleocapsid protein; emergency ward;
D O I
10.3390/microorganisms9040798
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Following the Swiss Federal Office of Public Health (FOPH) authorization of the rapid antigen test (RAT), we implemented the use of the RAT in the emergency ward of our university hospital for patients' cohorting. RAT triaging in association with RT-PCR allowed us to promptly isolate positive patients and save resources. Among 532 patients, overall sensitivities were 48.3% for Exdia and 41.2% for Standard Q(R), Panbio(TM) and BD Veritor (TM). All RATs exhibited specificity above 99%. Sensitivity increased to 74.6%, 66.2%, 66.2% and 64.8% for Exdia, Standard Q(R), Panbio(TM) and BD Veritor (TM), respectively, for viral loads above 10(5) copies/mL, to 100%, 97.8%, 96.6% and 95.6% for viral loads above 10(6) copies/mL and 100% for viral loads above 10(7) copies/mL. Sensitivity was significantly higher for patients with symptoms onset within four days (74.3%, 69.2%, 69.2% and 64%, respectively) versus patients with the evolution of symptoms longer than four days (36.8%, 21.1%, 21.1% and 23.7%, respectively). Among COVID-19 asymptomatic patients, sensitivity was 33%. All Immunoglobulin-A-positive patients resulted negative for RAT. The RAT might represent a useful resource in selected clinical settings as a complementary tool in RT-PCR for rapid patient triaging, but the lower sensitivity, especially in late presenters and COVID-19 asymptomatic subjects, must be taken into account.
引用
收藏
页数:13
相关论文
共 24 条
[1]   Field evaluation of a rapid antigen test (Panbio™ COVID-19 Ag Rapid Test Device) for COVID-19 diagnosis in primary healthcare centres [J].
Albert, Eliseo ;
Torres, Ignacio ;
Bueno, Felipe ;
Huntley, Dixie ;
Molla, Estefania ;
Angel Fernandez-Fuentes, Miguel ;
Martinez, Mireia ;
Poujois, Sandrine ;
Forque, Lorena ;
Valdivia, Arantxa ;
Solano de la Asuncion, Carlos ;
Ferrer, Josep ;
Colomina, Javier ;
Navarro, David .
CLINICAL MICROBIOLOGY AND INFECTION, 2021, 27 (03) :472.e7-472.e10
[2]  
Berger A., 2020, DIAGNOSTIC ACCURACY, DOI 10.1101/2020.11.20.20235341
[3]   Implementing SARS-CoV-2 Rapid Antigen Testing in the Emergency Ward of a Swiss University Hospital: The INCREASE Study [J].
Caruana, Giorgia ;
Croxatto, Antony ;
Kampouri, Eleftheria ;
Kritikos, Antonios ;
Opota, Onya ;
Foerster, Maryline ;
Brouillet, Rene ;
Senn, Laurence ;
Lienhard, Reto ;
Egli, Adrian ;
Pantaleo, Giuseppe ;
Carron, Pierre-Nicolas ;
Greub, Gilbert .
MICROORGANISMS, 2021, 9 (04)
[4]  
ECDC, West Nile Fever in Europe in 2018-Human Cases Compared to Previous Seasons
[5]   Evaluation of the Panbio COVID-19 Rapid Antigen Detection Test Device for the Screening of Patients with COVID-19 [J].
Fenollar, Florence ;
Bouam, Amar ;
Ballouche, Mehdi ;
Fuster, Lea ;
Prudent, Elsa ;
Colson, Philippe ;
Tissot-Dupont, Herve ;
Million, Matthieu ;
Drancourt, Michel ;
Raoult, Didier ;
Fournier, Pierre-Edouard .
JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (02)
[6]  
FOPH, COR TESTS
[7]  
Foundation of Innovative New Diagnostics (FIND), SARS COV 2 DIAGN PIP
[8]  
Gilbert G, 2020, PIPETTE SWISS LAB ME, V6, P18
[9]   Ten years of R&D and full automation in molecular diagnosis [J].
Greub, Gilbert ;
Sahli, Roland ;
Brouillet, Rene ;
Jaton, Katia .
FUTURE MICROBIOLOGY, 2016, 11 (03) :403-425
[10]   Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China [J].
Huang, Chaolin ;
Wang, Yeming ;
Li, Xingwang ;
Ren, Lili ;
Zhao, Jianping ;
Hu, Yi ;
Zhang, Li ;
Fan, Guohui ;
Xu, Jiuyang ;
Gu, Xiaoying ;
Cheng, Zhenshun ;
Yu, Ting ;
Xia, Jiaan ;
Wei, Yuan ;
Wu, Wenjuan ;
Xie, Xuelei ;
Yin, Wen ;
Li, Hui ;
Liu, Min ;
Xiao, Yan ;
Gao, Hong ;
Guo, Li ;
Xie, Jungang ;
Wang, Guangfa ;
Jiang, Rongmeng ;
Gao, Zhancheng ;
Jin, Qi ;
Wang, Jianwei ;
Cao, Bin .
LANCET, 2020, 395 (10223) :497-506