Wearable technology reveals gait compensations, unstable walking patterns and fatigue in people with multiple sclerosis

被引:34
作者
Psarakis, Michael [1 ]
Greene, David A. [1 ]
Cole, Michael H. [1 ]
Lord, Stephen R. [2 ]
Phu Hoang [1 ,2 ]
Brodie, Matthew [2 ,3 ]
机构
[1] Australian Catholic Univ, Fac Hlth Sci, Sydney, NSW, Australia
[2] Univ New South Wales, Neurosci Res Australia, Sydney, NSW, Australia
[3] UNSW, Grad Sch Biomed Engn, Sydney, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
harmonic ratio; accelerometer; dynamic stability; compensations; gait screening; PASSIVE MECHANICAL-PROPERTIES; PARKINSONS-DISEASE; OLDER-PEOPLE; ACCELERATION PATTERNS; CEREBRAL-PALSY; HEAD; PELVIS; GASTROCNEMIUS; OSCILLATIONS; INDIVIDUALS;
D O I
10.1088/1361-6579/aac0a3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: People with multiple sclerosis (PwMS) often experience a dedine in gait performance, which can compromise their independence and increase falls. Ankle joint contractures in PWMS are common and often result in compensatory gait patterns to accommodate reduced ankle range of motion (ROM). Approach: Using advances in wearable technology, the aim of this study was to quantify head and pelvis movement patterns that occur in PwMS with disability and determine how these secondary gait compensations impact on gait stability. Twelve healthy participants and 12 PwMS participated in the study. Head and pelvis movements were measured using two tri-axial accelerometers. Measures of gait compensation, mobility, variability, asymmetry, stability and fatigue were assessed during a 6 min walking test. Main results: Compared to healthy controls, PwMS had greater vertical asymmetry in their head and pelvic movements (Cohen's d = 1.85 and 1.60). Lower harmonic ratios indicated that PwMS were more unstable than controls (Cohen's d = -1.61 to -3.06), even after adjusting for their slower walking speeds. In the PWMS, increased compensatory movements were correlated with reduced ankle active ROM (r = -0.71), higher disability (EDSS) scores (r = 0.58), unstable gait (r = -0.76), reduced mobility (r = -0.76) and increased variability (r = 0.83). Significance: Wearable device technology provides an efficient and reliable way to screen for excessive compensatory movements often present in PWMS and provides clinically important information that impacts on mobility, stride time variability and gait stability. This information may help clinicians identify PWMS at high risk of falling and develop better rehabilitation interventions that, in addition to improving mobility, may help target the underlying causes of unstable gait.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Measuring Gait Stability in People with Multiple Sclerosis Using Different Sensor Locations and Time Scales
    Mueller, Roy
    Schreff, Lucas
    Koch, Lisa-Eyleen
    Oschmann, Patrick
    Hamacher, Daniel
    SENSORS, 2021, 21 (12)
  • [42] Biofeedback Based Home Balance Training can Improve Balance but Not Gait in People with Multiple Sclerosis
    Novotna, Klara
    Janatova, Marketa
    Hana, Karel
    Svestkova, Olga
    Lizrova, Jana Preiningerova
    Havrdova, Eva Kubala
    MULTIPLE SCLEROSIS INTERNATIONAL, 2019, 2019
  • [43] Walking performance differs between people with multiple sclerosis who perform distinct types of exercise
    Johnson, Kristin A.
    Bandera, Victoria M.
    Diehl, Manfred
    Leach, Heather J.
    Fling, Brett W.
    NEURODEGENERATIVE DISEASE MANAGEMENT, 2024, 14 (3-4) : 75 - 85
  • [44] Matching and accepting assistive technology in multiple sclerosis: A focus group study with people with multiple sclerosis, carers and occupational therapists
    Squires, Luke A.
    Williams, Nefyn
    Morrison, Val L.
    JOURNAL OF HEALTH PSYCHOLOGY, 2019, 24 (04) : 480 - 494
  • [45] Perceptions of fatigue and fatigue management interventions among people with multiple sclerosis: a systematic literature review and narrative synthesis
    Power, Mide
    Arafa, Nora
    Wenz, Anke
    Foley, Geraldine
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2021, 28 (06)
  • [46] Short inertial sensor-based gait tests reflect perceived state fatigue in multiple sclerosis
    Ibrahim, Alzhraa A.
    Flachenecker, Felix
    Gassner, Heiko
    Rothhammer, Veit
    Klucken, Jochen
    Eskofier, Bjoern M.
    Kluge, Felix
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2022, 58
  • [47] Inertial sensor-based gait parameters reflect patient-reported fatigue in multiple sclerosis
    Ibrahim, Alzhraa A.
    Kuederle, Arne
    Gassner, Heiko
    Klucken, Jochen
    Eskofier, Bjoern M.
    Kluge, Felix
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)
  • [48] Inertial sensor-based gait parameters reflect patient-reported fatigue in multiple sclerosis
    Alzhraa A. Ibrahim
    Arne Küderle
    Heiko Gaßner
    Jochen Klucken
    Bjoern M. Eskofier
    Felix Kluge
    Journal of NeuroEngineering and Rehabilitation, 17
  • [49] Clinical assessment of gait in individuals with multiple sclerosis using wearable inertial sensors: Comparison with patient-based measure
    Pau, Massimiliano
    Caggiari, Silvia
    Mura, Alessandro
    Corona, Federica
    Leban, Bruno
    Coghe, Giancarlo
    Lorefice, Lorena
    Marrosu, Maria Giovanna
    Cocco, Eleonora
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2016, 10 : 187 - 191
  • [50] Wearable Sensor Technologies to Assess Motor Functions in People With Multiple Sclerosis: Systematic Scoping Review and Perspective
    Woelfle, Tim
    Bourguignon, Lucie
    Lorscheider, Johannes
    Kappos, Ludwig
    Naegelin, Yvonne
    Jutzeler, Catherine Ruth
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2023, 25