Wearable technology reveals gait compensations, unstable walking patterns and fatigue in people with multiple sclerosis

被引:34
|
作者
Psarakis, Michael [1 ]
Greene, David A. [1 ]
Cole, Michael H. [1 ]
Lord, Stephen R. [2 ]
Phu Hoang [1 ,2 ]
Brodie, Matthew [2 ,3 ]
机构
[1] Australian Catholic Univ, Fac Hlth Sci, Sydney, NSW, Australia
[2] Univ New South Wales, Neurosci Res Australia, Sydney, NSW, Australia
[3] UNSW, Grad Sch Biomed Engn, Sydney, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
harmonic ratio; accelerometer; dynamic stability; compensations; gait screening; PASSIVE MECHANICAL-PROPERTIES; PARKINSONS-DISEASE; OLDER-PEOPLE; ACCELERATION PATTERNS; CEREBRAL-PALSY; HEAD; PELVIS; GASTROCNEMIUS; OSCILLATIONS; INDIVIDUALS;
D O I
10.1088/1361-6579/aac0a3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: People with multiple sclerosis (PwMS) often experience a dedine in gait performance, which can compromise their independence and increase falls. Ankle joint contractures in PWMS are common and often result in compensatory gait patterns to accommodate reduced ankle range of motion (ROM). Approach: Using advances in wearable technology, the aim of this study was to quantify head and pelvis movement patterns that occur in PwMS with disability and determine how these secondary gait compensations impact on gait stability. Twelve healthy participants and 12 PwMS participated in the study. Head and pelvis movements were measured using two tri-axial accelerometers. Measures of gait compensation, mobility, variability, asymmetry, stability and fatigue were assessed during a 6 min walking test. Main results: Compared to healthy controls, PwMS had greater vertical asymmetry in their head and pelvic movements (Cohen's d = 1.85 and 1.60). Lower harmonic ratios indicated that PwMS were more unstable than controls (Cohen's d = -1.61 to -3.06), even after adjusting for their slower walking speeds. In the PWMS, increased compensatory movements were correlated with reduced ankle active ROM (r = -0.71), higher disability (EDSS) scores (r = 0.58), unstable gait (r = -0.76), reduced mobility (r = -0.76) and increased variability (r = 0.83). Significance: Wearable device technology provides an efficient and reliable way to screen for excessive compensatory movements often present in PWMS and provides clinically important information that impacts on mobility, stride time variability and gait stability. This information may help clinicians identify PWMS at high risk of falling and develop better rehabilitation interventions that, in addition to improving mobility, may help target the underlying causes of unstable gait.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Gyroscopic corrections improve wearable sensor data prior to measuring dynamic sway in the gait of people with Multiple Sclerosis
    Brodie, Matthew A. D.
    Psarakis, Michael
    Phu Hoang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (12) : 1339 - 1346
  • [2] Quantifying muscle fatigue during walking in people with multiple sclerosis
    Eken, Maaike M.
    Richards, Rosie
    Beckerman, Heleen
    van der Krogt, Marjolein
    Gerrits, Karin
    Rietberg, Marc
    de Groot, Vincent
    Heine, Martin
    CLINICAL BIOMECHANICS, 2020, 72 : 94 - 101
  • [3] Eight-Week Remote Monitoring Using a Freely Worn Device Reveals Unstable Gait Patterns in Older Fallers
    Brodie, Matthew A.
    Lord, Stephen R.
    Coppens, Milou J.
    Annegarn, Janneke
    Delbaere, Kim
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) : 2588 - 2594
  • [4] Pilot trial of speed-intensive gait training on balance and walking in people with multiple sclerosis
    Karpatkin, Herb, I
    Benson, Allison
    Gardner, Nolan
    Leb, Naomi
    Ramos, Nicole
    Xu, Huiman
    Cohen, Evan T.
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2020, 27 (11):
  • [5] Spatial constraints and cognitive fatigue affect motor imagery of walking in people with multiple sclerosis
    Podda, Jessica
    Pedulla, Ludovico
    Monti Bragadin, Margherita
    Piccardo, Elisa
    Battaglia, Mario Alberto
    Brichetto, Giampaolo
    Bove, Marco
    Tacchino, Andrea
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Wearable inertial sensors are highly sensitive in the detection of gait disturbances and fatigue at early stages of multiple sclerosis
    Mueller, Roy
    Hamacher, Daniel
    Hansen, Sascha
    Oschmann, Patrick
    Keune, Philipp M.
    BMC NEUROLOGY, 2021, 21 (01)
  • [7] Responsiveness and clinically meaningful changes for the Persian versions of the multiple sclerosis walking scale-12 and the modified fatigue impact scale following balance and gait rehabilitation in people with multiple sclerosis
    Monjezi, Saeideh
    Molhemi, Farshad
    Yazdi, Mohammad-Jafar Shaterzadeh
    Salehi, Reza
    Mehravar, Mohammad
    Kashipazha, Davood
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (03) : 464 - 470
  • [8] Monitoring gait in multiple sclerosis with novel wearable motion sensors
    Moon, Yaejin
    McGinnis, Ryan S.
    Seagers, Kirsten
    Motl, Robert W.
    Sheth, Nirav
    Wright, John A., Jr.
    Ghaffari, Roozbeh
    Sosnoff, Jacob J.
    PLOS ONE, 2017, 12 (02):
  • [9] Manifestations of walking fatigability in people with multiple sclerosis based on gait quality and distance walked during the six minutes walking test
    Santinelli, Felipe Balistieri
    Abasiyanik, Zuhal
    Ramari, Cintia
    Gysemberg, Griet
    Kos, Daphne
    Pau, Massimiliano
    Kalron, Alon
    Meyns, Pieter
    Ozakbas, Serkan
    Feys, Peter
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2024, 91
  • [10] Wearable devices for gait and posture monitoring via telemedicine in people with movement disorders and multiple sclerosis: a systematic review
    Salaorni, Francesca
    Bonardi, Giulia
    Schena, Federico
    Tinazzi, Michele
    Gandolfi, Marialuisa
    EXPERT REVIEW OF MEDICAL DEVICES, 2024, 21 (1-2) : 121 - 140