Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: Comparison of Goldmann applanation tonometer with pneumatonometer

被引:0
作者
Baypaktar, S
Bayraktar, Z
机构
[1] Istanbul Surg Hosp, Istanbul, Turkey
[2] Beyoglu Eye Educ & Res Hosp, Istanbul, Turkey
关键词
central corneal thickness; intraocular pressure; Goldmann applanation tonometer; pneumatonometer; optical coherence tomography; LASIK;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate central corneal thickness (CCT) and intraocular pressure (IOP) relationship in eyes with and without previous corneal laser refractive surgery and to compare the estimates of two different tonometers-Goldmann applanation and pneumatonometer. METHODS. The study population included 234 glaucoma suspects who were referred to the glaucoma clinic with cup/disc ratios greater than 0.4, asymmetric cupping, and/or IOP greater than 22 mmHg during routine eye examination. Of those, 84 had previous myopic laser-assisted in situ keratomileusis (LASIK) (Group 1) while 150 of them did not (Group 2). CCT was measured by using optical coherence tomography (OCT) and IOP with both Goldmann applanation tonometer (GAT) and pneumatonometer (PT). In both groups, the difference between IOP estimates of two different tonometers and the relationship between CCT and IOP were analyzed. RESULTS. In eyes with previous LASIK, GAT measured IOP significantly lower than PT (mean difference of 3.8 +/- 1.9 mmHg, p < 0.0001). In eyes with virgin corneas, IOP estimates of GAT or PT were not different from each other (19.9 +/- 2.8 versus 19.9 +/- 2.2 mmHg, respectively, p = 0.81). In both groups, there was a significant positive correlation between CCT and IOP estimates of GAT (R = 0.29, p = 0.007 in eyes with LASIK and R = 0.38, p < 0.0001 in those without), while no similar relationship was present between CCT with those of PT (R = 0.03, p = 0.76 in eyes with LASIK and R = 0.03, p = 0.69 in those without). CONCLUSIONS. In eyes with previous LASIK, GAT measured IOP significantly lower than PT Because IOP estimates of PT were found to be independent from CCT in all of the study eyes, this device was considered to be a more reliable method of IOP estimation than GAT in eyes with and without previous LASIK.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
    Saleh, Tarek A.
    Adams, Morag
    McDermott, Bill
    Claridge, Kate G.
    Ewings, Paul
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06) : 516 - 520
  • [2] Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
    Yaoeda, Kiyoshi
    Fukushima, Atsushi
    Shirakashi, Motohiro
    Fukuchi, Takeo
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 829 - 834
  • [3] Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs
    Park, Young-Woo
    Jeong, Man-Bok
    Kim, Tae-Hyun
    Ahn, Jae-Sang
    Ahn, Jeong-Taek
    Park, Shin-Ae
    Kim, Se-Eun
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2011, 14 (03) : 169 - 173
  • [4] Comparability of Icare Pro Rebound Tonometer with Goldmann Applanation and Noncontact Tonometer in a Wide Range of Intraocular Pressure and Central Corneal Thickness
    Tamcelik, Nevbahar
    Atalay, Eray
    Cicik, Erdogan
    Ozkok, Ahmet
    OPHTHALMIC RESEARCH, 2015, 54 (01) : 18 - 25
  • [5] Relationship of Central Corneal Thickness and Intraocular Pressure by iCare Rebound Tonometer
    Rao, Aparna
    Kumar, Mukesh
    Prakash, B.
    Varshney, Gopal
    JOURNAL OF GLAUCOMA, 2014, 23 (06) : 380 - 384
  • [6] Clinical comparison of ocular blood flow tonometer, tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes
    Rao, VJ
    Gnanaraj, L
    Mitchell, KW
    Figueiredo, FC
    CORNEA, 2001, 20 (08) : 834 - 838
  • [7] A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry
    Popovich, KS
    Shields, MB
    JOURNAL OF GLAUCOMA, 1997, 6 (01) : 44 - 46
  • [8] Postural Change in Intraocular Pressure: A Comparison of Measurement With a Goldmann Tonometer, Tonopen XL, Pneumatonometer, and HA-2
    Barkana, Yaniv
    JOURNAL OF GLAUCOMA, 2014, 23 (01) : E23 - E28
  • [9] Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates of intraocular pressure
    Hamilton, Kirsten Elizabeth
    Pye, David Cecil
    Aggarwala, Shivani
    Evian, Sindy
    Khosla, Joti
    Perera, Rachithri
    JOURNAL OF GLAUCOMA, 2007, 16 (01) : 29 - 35
  • [10] Assessment of intraocular pressure measurement between Goldman applanation tonometer, rebound tonometer, non-contact tonometer, and its correlation with central corneal thickness
    Porwal, Amit C.
    Shrishrimal, Meghna
    Punamia, Ravin P.
    Mathew, Bennet Chacko
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 1927 - 1931