Optoelectric biosensor using indium-tin-oxide electrodes

被引:14
作者
Choi, Chang Kyoung [1 ]
Kihm, Kenneth D. [1 ]
English, Anthony E. [1 ]
机构
[1] Univ Tennessee, Dept Mech Aerosp & Biomed Engn, Knoxville, TN 37996 USA
关键词
D O I
10.1364/OL.32.001405
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The use of an optically thin indium-tin-oxide (ITO) electrode is presented for an optoelectric biosensor simultaneously recording optical images and microimpedance to examine time-dependent cellular growth. The transmittance of a 100 nm thick ITO electrode layer is approximately the same as the transmittance of a clean glass substrate, whereas the industry-standard Au (47.5 nm)/Ti (2.5 nm) electrode layer drops the transmittance to less than 10% of that of the glass substrate. The simultaneous optoelectric measurements permit determining the correlation of the cell-covered area increase with the microimpedance increase, and the example results obtained for live porcine pulmonary artery endothelial cells delineate the quantitative and comprehensive nature of cellular attachment and spreading to the substrate, which has not been clearly perceived before. (c) 2007 Optical Society of America.
引用
收藏
页码:1405 / 1407
页数:3
相关论文
共 7 条
[1]   An endothelial cell compatible biosensor fabricated using optically thin indium tin oxide silicon nitride electrodes [J].
Choi, Chang K. ;
English, Anthony E. ;
Jun, Seung-K ;
Kihm, Kenneth D. ;
Rack, Philip D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2585-2590
[2]   MONITORING FIBROBLAST BEHAVIOR IN TISSUE-CULTURE WITH AN APPLIED ELECTRIC-FIELD [J].
GIAEVER, I ;
KEESE, CR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (12) :3761-3764
[3]   Electrical and optical characterization of thrombin-induced permeability of cultured endothelial cell monolayers on semiconductor electrode arrays [J].
Hillebrandt, H ;
Abdelghani, A ;
Abdelghani-Jacquin, C ;
Aepfelbacher, M ;
Sackmann, E .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2001, 73 (05) :539-546
[4]   TFT-LCD technology [J].
Katayama, M .
THIN SOLID FILMS, 1999, 341 (1-2) :140-147
[5]   PROPERTIES OF TIN DOPED INDIUM OXIDE THIN-FILMS PREPARED BY MAGNETRON SPUTTERING [J].
RAY, S ;
BANERJEE, R ;
BASU, N ;
BATABYAL, AK ;
BARUA, AK .
JOURNAL OF APPLIED PHYSICS, 1983, 54 (06) :3497-3501
[6]   HIGH-PRECISION MEASUREMENT OF ELECTRICAL-RESISTANCE ACROSS ENDOTHELIAL-CELL MONOLAYERS [J].
TSCHUGGUEL, W ;
ZHEGU, Z ;
GAJDZIK, L ;
MAIER, M ;
BINDER, BR ;
GRAF, J .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1995, 430 (01) :145-147
[7]   Assessment of cytotoxicity using electric cell-substrate impedance sensing: Concentration and time response function approach [J].
Xiao, CD ;
Lachance, B ;
Sunahara, G ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2002, 74 (22) :5748-5753