Analysis and validation of a 3D finite element model for human forearm fracture

被引:2
|
作者
Liu, Jing [1 ,2 ]
Mustafa, Al-Khazraji [3 ]
Lees, Vivien C. [4 ]
Qian, Zhihui [1 ,2 ]
Wei, Guowu [5 ]
Lu, Xuewei [3 ]
Jin, Jianqiao [1 ]
Ren, Lei [1 ,3 ]
Ren, Luquan [1 ,2 ]
Wang, Kunyang [1 ,2 ]
机构
[1] Jilin Univ, Key Lab Bion Engn, Minist Educ, Changchun 130022, Peoples R China
[2] Jilin Univ, Weihai Inst Bion, Weihai, Peoples R China
[3] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[4] Univ Hosp South Manchester, Dept Reconstruct Plast Surg, Wythenshawe, England
[5] Univ Salford, Sch Sci Engn & Environm, Salford, Lancs, England
基金
中国国家自然科学基金;
关键词
biomechanics; finite element analysis; human forearm fracture; interosseous ligament; DISTAL RADIUS; MECHANICAL-PROPERTIES; LOAD; BONE; BIOMECHANICS; PREDICTION; FAILURE; ANATOMY; ULNA;
D O I
10.1002/cnm.3617
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most researchers have performed finite element (FE) analysis of the human forearm fracture by exploring the strength and load transmission of the bones. However, few studies concentrated a complete simulation of the whole forearm complex including ligaments. This paper aims to investigate the load transmission through the bones, contact stress at the joints and strain in the ligaments by using an elaborate FE model, further validating the fracture condition for human forearm. The interosseous ligament was separated into three regions based on the distance to the proximal and distal ends. The FE simulation results were slightly more or less than a previous experimental data in the literature, but generally provided a close approximation of the bone and ligament behaviors. Compared with the experiment results under different loading conditions, maximum contact stress at the proximal radio ulnar joint (PRUJ) and distal radio ulnar joint (DRUJ) of the simulations was higher with an average of 13.4%, and peak strain in the interosseous ligament (IOL) was lower with an average of 11.0%. Under 10 kg load, the maximum stress in the radius (2.25 MPa) was less than double the value in the ulna (1.43 MPa). Finally, the FE model has been validated with the onset and location of the Colles' fracture in the literature. This study will provide a great benefit in terms of surgical and medical applications related to forearm fracture that require an extensive knowledge of the behavior of the bones and ligaments under various loading conditions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Finite Element Analysis of 2.5D Woven Composites, Part I: Microstructure and 3D Finite Element Model
    Jian Song
    Weidong Wen
    Haitao Cui
    Hongjian Zhang
    Ying Xu
    Applied Composite Materials, 2016, 23 : 29 - 44
  • [22] Finite Element Analysis of 2.5D Woven Composites, Part I: Microstructure and 3D Finite Element Model
    Song, Jian
    Wen, Weidong
    Cui, Haitao
    Zhang, Hongjian
    Xu, Ying
    APPLIED COMPOSITE MATERIALS, 2016, 23 (01) : 29 - 44
  • [23] 3D geometrical model of plain weave fabrics for finite element analysis
    Wang, Dongning
    Jiao, Ya-nan
    Li, Jialu
    ADVANCED TEXTILE MATERIALS, PTS 1-3, 2011, 332-334 : 1635 - 1638
  • [24] Finite Element Analysis of 3D Printed Model via Compression Tests
    Abbot, D. W.
    Kallon, D. V. V.
    Anghel, C.
    Dube, P.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2019), 2019, 35 : 164 - 173
  • [25] ANALYSIS OF THE IMPEDANCE FUNCTIONS USING 3D FINITE ELEMENT MODEL OF SUBSOIL
    Kralik, J.
    Rosko, P.
    Kralik, J., Jr.
    ENGINEERING MECHANICS 2018 PROCEEDINGS, VOL 24, 2018, : 425 - 428
  • [26] REDUCED MATERIAL MODEL OF COMPOSITE LAMINATES FOR 3D FINITE ELEMENT ANALYSIS
    Kumar, Goldy
    Shapiro, Vadim
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 1A, 2014,
  • [27] Finite element model validation in biomechanics using a 3D scanning Laser Doppler Vibrometer
    Srinivas-Nurani, Ananth
    von-der-Lieth, Arend
    Bright, Jen
    Rayfield, Emily
    Goldsby, David
    Sullan, Lauren
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2024, 64 : S484 - S485
  • [28] Experimental validation of a 3D dynamic finite-element model of a total knee replacement
    Lanovaz, JL
    Ellis, RE
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 917 - 924
  • [29] Stability Analysis of Ecological Slopes Based on a 3D Finite Element Model
    Sui, Zifan
    Yuan, Weijia
    Yi, Wen
    Yang, Weihuan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2021, 2021
  • [30] A 3D finite element model for the vibration analysis of asymmetric rotating machines
    Lazarus, A.
    Prabel, B.
    Combescure, D.
    JOURNAL OF SOUND AND VIBRATION, 2010, 329 (18) : 3780 - 3797