Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale

被引:28
作者
Monte, Ines [1 ]
Grasso, Stefania [1 ]
Licciardi, Salvatore [1 ]
Badano, Luigi P. [2 ]
机构
[1] Policlin Univ, Echo Dept, I-95125 Catania, Italy
[2] Univ Hosp, Dept Cardiopulm Sci, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 03期
关键词
Echocardiography; Contrast; Three-dimensional echocardiography; Patent foramen ovale; Transesophageal; Cryptogenetic stroke; Divers; INTERATRIAL SHUNTS; AIR-EMBOLISM; TECHNOLOGY; ASSOCIATION; COMMITTEE;
D O I
10.1093/ejechocard/jep195
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the incremental value of real-time three-dimensional echocardiography (RT-3DTE) over contrast transthoracic echocardiography (TTE), compared with contrast transesophageal echocardiography (TEE) in the identification of patent foramen ovale (PFO). Eighty-one consecutive patients with history of migraine headache (MH) or unexplained cerebrovascular events (CE) were examined using RT-3DTE, contrast TTE, and contrast TEE in sequence. Feasibility of RT-3DE in patients with MH and CE was 98 and 91%, respectively. Mean time for 3D colour data set acquisition was 9 +/- 5 min. PFO was diagnosed using contrast TEE in 36 patients (overall prevalence = 44%). Diagnostic accuracy of RT-3DE was significantly higher than that of contrast TTE: sensitivity 83 vs. 44%, P < 0.001; specificity 100 vs. 100%, P7 = NS; positive predictive value 100 vs. 100%, P = NS; negative predictive value 88 vs. 69%, P < 0.01; accuracy 93 vs. 75%, P < 0.003. Five of the six patients in whom RT-3DTE did not identify PFOs showed a defect diameter smaller than 2 mm. RT-3DTE is a feasible, accurate, and reproducible technique to detect PFO without the need of saline contrast injection. Its accuracy is superior to contrast 2D TTE and close to that of contrast TEE.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
[31]   Two-Dimensional Versus Transthoracic Real-Time Three-Dimensional Echocardiography in the Evaluation of the Mechanisms and Sites of Atrioventricular Valve Regurgitation in a Congenital Heart Disease Population [J].
Takahashi, Ken ;
Mackie, Andrew S. ;
Rebeyka, Ivan M. ;
Ross, David B. ;
Robertson, Murray ;
Dyck, John D. ;
Inage, Akio ;
Smallhorn, Jeffrey F. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) :726-734
[32]   Two-dimensional transthoracic measure of mitral annulus in mitral valve prolapse and moderate to severe regurgitation: a method comparison analysis with three-dimensional transesophageal echocardiography [J].
Maxime Berthelot-Richer ;
Halyna Viktorivna Vakulenko ;
Anna Calleja ;
Anna Woo ;
Paaladinesh Thavendiranathan ;
Frédéric Poulin .
Journal of Cardiovascular Imaging, 32 (1)
[33]   Incremental Value of Live/Real Time Three-Dimensional Transthoracic Echocardiography over Two-Dimensional Echocardiography in Hypertrophic Cardiomyopathy with Mid-Ventricular Obstruction and Apical Aneurysm [J].
Thind, Munveer ;
Joson, Marisa ;
Gaba, Saurabh ;
Elsayed, Mahmoud ;
Bulur, Serkan ;
Guvenc, Tolga ;
Elguindy, Mostafa ;
Nanda, Navin C. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (03) :565-569
[34]   Right-to-left shunt detection in patent foramen ovale: The value of synchronized contrast transcranial Doppler and contrast transthoracic echocardiography [J].
Wang, Yu-Yin ;
Xie, Lu ;
Feng, Jun-Bang ;
Xu, Yang-Yang ;
Li, Chuan-Ming .
WORLD JOURNAL OF RADIOLOGY, 2025, 17 (05)
[35]   Comparative assessment of left atrial appendage by transesophageal and combined two- and three-dimensional transthoracic echocardiography [J].
Karakus, Gultekin ;
Kodali, Visali ;
Inamdar, Vatsal ;
Nanda, Navin C. ;
Suwanjutah, Thouantosaporn ;
Pothineni, Koteswara R. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (08) :918-924
[36]   Three-dimensional compared to two-dimensional transesophageal echocardiography for diagnosis of infective endocarditis [J].
Roman Pfister ;
Yann Betton ;
Henrik ten Freyhaus ;
Norma Jung ;
Stephan Baldus ;
Guido Michels .
Infection, 2016, 44 :725-731
[37]   Three-dimensional compared to two-dimensional transesophageal echocardiography for diagnosis of infective endocarditis [J].
Pfister, Roman ;
Betton, Yann ;
ten Freyhaus, Henrik ;
Jung, Norma ;
Baldus, Stephan ;
Michels, Guido .
INFECTION, 2016, 44 (06) :725-731
[38]   Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure [J].
Zhao, Hongling ;
Yue, Qingxiong ;
Wang, Tao ;
Wang, Lin ;
Pang, Zhanqi ;
Dong, He ;
Yang, Jian ;
Li, Yawen ;
Li, Shijun .
MEDICINE, 2019, 98 (04)
[39]   Real-time three-dimensional echocardiography for left atrial volume assessment in Thoroughbred racehorses: Observer variability and comparison with two-dimensional echocardiography [J].
Worsman, Francesca C. F. ;
Miller, Zack J. ;
Shaw, Darren J. ;
Blissitt, Karen J. ;
Keen, John A. .
EQUINE VETERINARY JOURNAL, 2022, 54 (01) :176-190
[40]   Real Time Three-Dimensional Transesophageal Echocardiographic Images of Platypnea-Orthodeoxia Due to Patent Foramen Ovale [J].
Sasaki, Toshiharu ;
Miyasaka, Yoko ;
Suwa, Yoshinobu ;
Senoo, Takeshi ;
Ohtagaki, Munemitsu ;
Maeba, Hirofumi ;
Tsujimoto, Satoshi ;
Shiojima, Ichiro .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (04) :E116-E117