Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale

被引:27
|
作者
Monte, Ines [1 ]
Grasso, Stefania [1 ]
Licciardi, Salvatore [1 ]
Badano, Luigi P. [2 ]
机构
[1] Policlin Univ, Echo Dept, I-95125 Catania, Italy
[2] Univ Hosp, Dept Cardiopulm Sci, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 03期
关键词
Echocardiography; Contrast; Three-dimensional echocardiography; Patent foramen ovale; Transesophageal; Cryptogenetic stroke; Divers; INTERATRIAL SHUNTS; AIR-EMBOLISM; TECHNOLOGY; ASSOCIATION; COMMITTEE;
D O I
10.1093/ejechocard/jep195
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the incremental value of real-time three-dimensional echocardiography (RT-3DTE) over contrast transthoracic echocardiography (TTE), compared with contrast transesophageal echocardiography (TEE) in the identification of patent foramen ovale (PFO). Eighty-one consecutive patients with history of migraine headache (MH) or unexplained cerebrovascular events (CE) were examined using RT-3DTE, contrast TTE, and contrast TEE in sequence. Feasibility of RT-3DE in patients with MH and CE was 98 and 91%, respectively. Mean time for 3D colour data set acquisition was 9 +/- 5 min. PFO was diagnosed using contrast TEE in 36 patients (overall prevalence = 44%). Diagnostic accuracy of RT-3DE was significantly higher than that of contrast TTE: sensitivity 83 vs. 44%, P < 0.001; specificity 100 vs. 100%, P7 = NS; positive predictive value 100 vs. 100%, P = NS; negative predictive value 88 vs. 69%, P < 0.01; accuracy 93 vs. 75%, P < 0.003. Five of the six patients in whom RT-3DTE did not identify PFOs showed a defect diameter smaller than 2 mm. RT-3DTE is a feasible, accurate, and reproducible technique to detect PFO without the need of saline contrast injection. Its accuracy is superior to contrast 2D TTE and close to that of contrast TEE.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
  • [1] Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale
    Maffe, Stefano
    Dellavesa, Pierfranco
    Zenone, Franco
    Paino, Anna Maria
    Paffoni, Paola
    Perucca, Antonello
    Kozel, Daniela
    Signorotti, Fabiana
    Bielli, Massimo
    Parravicini, Umberto
    Pardo, Nicolo Franchetti
    Cucchi, Lorenzo
    Aymele, Alain Guillaime
    Zanetta, Marco
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (01): : 57 - 63
  • [2] Comparison of Two-Dimensional Versus Real-Time Three-Dimensional Transesophageal Echocardiography for Evaluation of Patent Foramen Ovale Morphology
    Tanaka, Jun
    Izumo, Masaki
    Fukuoka, Yoko
    Saitoh, Takeji
    Harada, Kenji
    Harada, Kazumasa
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (07) : 1052 - 1056
  • [3] Three-dimensional and two-dimensional morphological features of patent foramen ovale revealed by transesophageal echocardiography
    Liu Mei
    Wang Jianhua
    Ding Guichun
    Duan Yaqi
    Sun Pengfei
    Jian Wenhao
    CHINESE MEDICAL JOURNAL, 2014, 127 (08) : 1590 - 1591
  • [4] COMPARISON OF TRANSTHORACIC ECHOCARDIOGRAPHY (VALSALVA MANEUVER) AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY (PEEP) FOR DETECTION OF PATENT FORAMEN OVALE
    PAPADOPOULOS, G
    DEPPERMANN, KM
    SCHRODER, K
    VOLLER, H
    KUHLY, P
    EYRICH, K
    ANAESTHESIST, 1994, 43 (09): : 582 - 586
  • [5] Preoperative detection of a patent foramen ovale: Rational use of transthoracic and transesophageal contrast echocardiography
    Weihs, W
    Schuchlenz, H
    Harb, S
    Schwarz, G
    Fuchs, G
    Weihs, B
    ANAESTHESIST, 1998, 47 (10): : 833 - +
  • [6] Comparison of Transthoracic Echocardiography, Transesophageal Echocardiography, and Transcranial Doppler in the Detection of Patent Foramen Ovale as the Etiology for Cryptogenic Stroke
    Stafford, Madison B.
    Bagley, Jennifer E.
    DiGiacinto, Dora
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2019, 35 (02) : 127 - 133
  • [7] Contrast transthoracic echocardiography versus transcranial Doppler for patent foramen ovale detection
    Corrado, Giovanni
    Massironi, Laura
    Torta, Daniela
    Rigo, Fausto
    Beretta, Sandro
    Sansalone, Dario
    Zenoni, Eleonora
    Mantero, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (02) : 235 - 237
  • [8] Enhanced detection of patent foramen ovale by systematic transthoracic saline contrast echocardiography
    Lam, Yat-Yin
    Yu, Cheuk-Man
    Zhang, Qing
    Yan, Bryan P.
    Yip, Gabriel Wai-Kwok
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 152 (01) : 24 - 27
  • [9] Comparison of two-dimensional and real-time three-dimensional transesophageal echocardiography in the assessment of aortic valve area
    Furukawa, Atsuko
    Abe, Yukio
    Tanaka, Chiharu
    Ito, Kazato
    Tabuchi, Isao
    Osawa, Kazuhiro
    Kino, Naoto
    Nakagawa, Eiichiro
    Komatsu, Ryushi
    Haze, Kazuo
    Yoshiyama, Minoru
    Yoshikawa, Junichi
    Naruko, Takahiko
    Itoh, Akira
    JOURNAL OF CARDIOLOGY, 2012, 59 (03) : 337 - 343
  • [10] Visualization of atrial septal aneurysm and patent foramen ovale by three-dimensional transesophageal echocardiography
    Najib, Mohammad Q.
    Ganji, Jhansi L.
    Chaliki, Hari P.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 : E237 - E238