摘要
Background: Rotating-hinge knee replacements are usually reserved for revision surgeries, when the extent of soft tissue loss makes a constrained implant more suitable. They remain an uncommon choice in primary surgery when the soft tissue loss is not as extensive. Methods: We completed a systematic review and meta-analysis to assess patients who underwent a Total Knee Replacement (TKR) with the rotating-hinge prosthesis in the primary setting. We searched PubMed and Embase for articles published in the ten years prior June 2017: Prosthesis survival rates, causes of failure, and clinical/functional scores were the primary outcomes. Twenty-one articles met the inclusion criteria for meta-analysis. Articles were grouped into (1) non-tumour (n=11) and (2) tumour indications (n=10). Survival data was summarized in forest plots, generated using Stata. Results: We found that for certain indications the prosthesis has impressive survival rates and functional outcomes. Short-term (1-5 year) prosthesis survival in non-tumour cases was 92% (95% CI, 87-98%) and 77% (95% CI, 68-87%) in tumour cases. Mid-term (6-10 year) survival was 82% (95% CI, 74-89%) and 69% (95% CI, 57-81%) in non-tumour and tumour studies respectively. In analysis of clinical scores, patients showed a significant improvement in their pain score. Infection was the most commonly cited cause of prosthesis failure in both non-tumour and tumour studies, attributing to 31.5% and 37.6% of failures respectively. Aseptic loosening, dislocation and fracture were also commonly cited complications. Conclusion: We concluded that the rotating-hinge knee prosthesis is a viable option in primary surgery when there is extensive soft tissue destruction surrounding the joint. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1351 / 1359
页数:9
相关论文
共 37 条
  • [31] Outcome after Reconstruction of the Proximal Tibia - Complications and Competing Risk Analysis
    Puchner, Stephan E.
    Kutscha-Lissberg, Paul
    Kaider, Alexandra
    Panotopoulos, Joannis
    Puchner, Rudolf
    Boehler, Christoph
    Hobusch, Gerhard
    Windhager, Reinhard
    Funovics, Philipp T.
    [J]. PLOS ONE, 2015, 10 (08):
  • [32] Custom rotating hinge total knee arthroplasty in patients with poliomyelitis affected limbs
    Rahman, Jeeshan
    Hanna, Sammy A.
    Kayani, Babar
    Miles, Jonathan
    Pollock, Robin C.
    Skinner, John A.
    Briggs, Timothy W.
    Carrington, Richard W.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) : 833 - 838
  • [33] Total knee arthroplasty with rotating-hinge Endo-Model prosthesis: clinical results in complex primary and revision surgery
    Sanguineti, F.
    Mangano, T.
    Formica, M.
    Franchin, F.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (11) : 1601 - 1607
  • [34] Custom rotating-hinge primary total knee arthroplasty in patients with skeletal dysplasia
    Sewell, M. D.
    Hanna, S. A.
    Al-Khateeb, H.
    Miles, J.
    Pollock, R. C.
    Carrington, R. W. J.
    Skinner, J. A.
    Cannon, S. R.
    Briggs, T. W. R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (03): : 339 - 343
  • [35] Methodological index for non-randomized studies (MINORS):: Development and validation of a new instrument
    Slim, K
    Nini, E
    Forestier, D
    Kwiatkowski, F
    Panis, Y
    Chipponi, J
    [J]. ANZ JOURNAL OF SURGERY, 2003, 73 (09) : 712 - 716
  • [36] Smith TH, 2013, J ARTHROPLASTY, V2013
  • [37] Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees
    Yang, Jae-Hyuk
    Yoon, Jung-Ro
    Oh, Chi-Hun
    Kim, Taik-Sun
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 517 - 523