Multi-objective thermo-economic optimization of a combined organic Rankine cycle and vapour compression refrigeration cycle

被引:49
作者
Salim, Mohammad Saad [1 ]
Kim, Man-Hoe [1 ]
机构
[1] Kyungpook Natl Univ, Sch Mech Engn, Daegu 41566, South Korea
关键词
ORC; Combined power and refrigeration cycle; Multi-objective optimization; Cycle efficiency; WASTE HEAT-RECOVERY; PERFORMANCE ANALYSIS; WORKING-FLUID; PARAMETRIC OPTIMIZATION; THERMODYNAMIC ANALYSIS; COMBINED POWER; ORC-VCC; SELECTION; SYSTEMS;
D O I
10.1016/j.enconman.2019.112054
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study focuses on the multi-objective optimization of a combined power (organic Rankine cycle) and vapour compression refrigeration cycle based on heat source temperatures ranging from 120 degrees C to 150 degrees C. The primary purpose is to achieve an optimal system through the use of efficiency and cost functions. The size of the heat exchangers and turbines (indicated by the total heat transfer coefficient UA(total) and size parameter SPtotal, respectively) used in the system affect the cost function of the system, whereas the efficiency function of the system is affected by the thermal efficiency (eta(th)) and the irreversibility ratio (IR value, representing the total exergy destruction) of the system. The sensitivity analysis conducted herein revealed that the eta(th), value increased by 107.9% when the evaporator pressure was varied from the minimum to the maximum value within the bound constraints, whereas the UA(total) value increased by 15.5%. The system was optimized based on six input parameters. The optimization results indicated that the system optimized for R236ea provided the lowest cost and the lowest system efficiency, system optimized for R245ca provided the highest cost and the highest system efficiency, and the system optimized for R245fa was between the two above-mentioned extremes in terms of cost and efficiency. At a heat source temperature of 150 degrees C and with R245fa as the ORC fluid, the optimum UA(total), eta(th), IR, and SPtotal values were 99.6 kW/K, 35.8%, 54.2%, and 0.386 dm, respectively.
引用
收藏
页数:15
相关论文
共 39 条
[1]  
[Anonymous], CLIMATE CHANGE 2007
[2]  
[Anonymous], PRINCIPLES ENG THERM
[3]  
[Anonymous], MATLAB MATHWORKS R20
[4]  
[Anonymous], P INT C GENET ALGORI
[5]  
[Anonymous], 2012, KTH IND ENG MANAG
[6]   Analysis of a combined Rankine-vapour-compression refrigeration cycle [J].
Aphornratana, Satha ;
Sriveerakul, Thanarath .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) :2557-2564
[7]   Performance analysis of high temperature cascade organic Rankine cycle coupled with water heating system [J].
Aziz, Faraz ;
Salim, Mohammad Saad ;
Kim, Man-Hoe .
ENERGY, 2019, 170 :954-966
[8]   Exergetic and heat load optimization of high temperature organic Rankine cycle [J].
Aziz, Faraz ;
Mudasar, Roshaan ;
Kim, Man-Hoe .
ENERGY CONVERSION AND MANAGEMENT, 2018, 171 :48-58
[9]   Organic Rankine Cycle Power Systems: From the Concept to Current Technology, Applications, and an Outlook to the Future [J].
Colonna, Piero ;
Casati, Emiliano ;
Trapp, Carsten ;
Mathijssen, Tiemo ;
Larjola, Jaakko ;
Turunen-Saaresti, Teemu ;
Uusitalo, Antti .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2015, 137 (10)
[10]   A fast and elitist multiobjective genetic algorithm: NSGA-II [J].
Deb, K ;
Pratap, A ;
Agarwal, S ;
Meyarivan, T .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) :182-197