Post-irradiation time effects on the graft of poly(ethylene-alt-tetrafluoroethylene) (ETFE) films for ion exchange membrane application

被引:12
|
作者
Geraldes, Adriana N. [1 ]
Zen, Heloisa A. [1 ]
Ribeiro, Geise [1 ]
Ferreira, Henrique P. [1 ]
Souza, Camila P. [1 ]
Parra, Duclerc F. [1 ]
Santiago, Elisabete I. [1 ]
Lugao, Adernar B. [1 ]
机构
[1] CQMA, IPEN, BR-05508900 Sao Paulo, Brazil
关键词
Poly(ethylene-alt-tetrafluoroethylene); Radiation-induced grafting; Styrene; POLYMER ELECTROLYTE MEMBRANES; FUEL-CELLS; RADIATION; STYRENE; FLUOROPOLYMERS;
D O I
10.1016/j.radphyschem.2009.08.029
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Grafting of styrene followed by sulfonation onto poly(ethylene-alt-tetrafluoroethylene) (ETFE) was studied for synthesis of ion exchange membranes. Radiation-induced grafting of styrene onto ETFE films was investigated after simultaneous irradiation (in post-irradiation condition) using a (60)Co source. The ETFE films were irradiated at 20 kGy dose at room temperature and chemical changes were monitored after contact with styrene for grafting. The post-irradiation time was established at 14 days when the films were remained in styrene/toluene 1:1 v/v. After this period the grafting degree was evaluated in the samples. The grafted films were sulfonated using chlorosulfonic acid and 1, 2-dichloroethane 20:80 (v/v) at room temperature for 5h. The membranes were analyzed by infrared spectroscopy (FTIR), differential scanning calorimeter (DSC), thermogravimetric measurements (TG) and degree of grafting (DOG). The ion exchange capacity (IEC) of membranes was determined by acid-base titration and the values for ETFE membranes were achieved higher than Nafion (R) films. Preliminary single cell performance was made using pure H(2) and O(2) as reactants at a cell temperature of 80 degrees C and atmospheric gas pressure. The fuel cell performance of ETFE films was satisfactory when compared to state-of-art Nafion (R) membranes. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 249
页数:4
相关论文
共 16 条
  • [1] Solvent effect on post-irradiation grafting of styrene onto poly(ethylene-alt-tetrafluoroethylene) (ETFE) films
    Geraldes, Adriana Napoleao
    Zen, Heloisa Augusto
    Ribeiro, Geise
    Parra, Duclerc Fernandes
    Lugao, Ademar Benevolo
    RADIATION PHYSICS AND CHEMISTRY, 2013, 84 : 205 - 209
  • [2] Influence of reaction parameters on grafting of styrene into poly(ethylene-alt-tetrafluoroethylene) films
    Guersel, Selmiye Alkan
    Ben youcef, Hicham
    Wokaun, Alexander
    Scherer, Guenther G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 265 (01): : 198 - 203
  • [3] A study on the morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method
    Song, Ju-Myung
    Ko, Beom-Seok
    Sohn, Joon-Yong
    Nho, Young Chang
    Shin, Junhwa
    RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 374 - 380
  • [4] Grafting of nitrogen containing monomers onto poly(ethylene-alt-tetrafluoroethylene) films by bulk polymerization for proton exchange membranes
    Fahed Takrori
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 1089 - 1094
  • [5] Grafting of nitrogen containing monomers onto poly(ethylene-alt-tetrafluoroethylene) films by bulk polymerization for proton exchange membranes
    Takrori, Fahed
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 308 (03) : 1089 - 1094
  • [6] Conversion of Poly(ethylene-alt-tetrafluoroethylene) Copolymers into Polytetrafluoroethylene by Direct Fluorination: A Convenient Approach to Access New Properties at the ETFE Surface
    Calleja, Gerard
    Houdayer, Axel
    Etienne-Calas, Sylvie
    Bourgogne, David
    Flaud, Valerie
    Silly, Gilles
    Shibahara, Sota
    Takahara, Atsushi
    Jourdan, Alex
    Hamwi, Andre
    Ameduri, Bruno
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2011, 49 (07) : 1517 - 1527
  • [7] Preparation of Polymer Electrolyte Membranes via Radiation-Induced Graft Copolymerization on Poly(ethylene-alt-tetrafluoroethylene) (ETFE) Using the Crosslinker N,N-Methylenebis(acrylamide)
    Ke, Xi
    Drache, Marco
    Gohs, Uwe
    Kunz, Ulrich
    Beuermann, Sabine
    MEMBRANES, 2018, 8 (04)
  • [8] Proton exchange membranes prepared by radiation grafting of styrene/divinylbenzene onto poly(ethylene-alt-tetrafluoroethylene) for low temperature fuel cells
    Gubler, L
    Prost, N
    Gürsel, SA
    Scherer, GG
    SOLID STATE IONICS, 2005, 176 (39-40) : 2849 - 2860
  • [9] Grafting of pre-irradiated poly(ethylene-alt-tetrafluoroethylene) films with styrene:: influence of base polymer film properties and processing parameters
    Brack, HP
    Bührer, HG
    Bonorand, L
    Scherer, GG
    JOURNAL OF MATERIALS CHEMISTRY, 2000, 10 (08) : 1795 - 1803
  • [10] Study on depth profile of heavy ion irradiation effects in poly(tetrafluoroethylene-co-ethylene)
    Gowa, Tomoko
    Shiotsu, Tomoyuki
    Urakawa, Tatsuya
    Oka, Toshitaka
    Murakami, Takeshi
    Oshima, Akihiro
    Hama, Yoshimasa
    Washio, Masakazu
    RADIATION PHYSICS AND CHEMISTRY, 2011, 80 (02) : 264 - 267