This paper introduces the performance improvement of a slip energy recovery drive system for the speed control of a wound rotor induction motor by a voltage-controlled technique. The slip energy occurred in the rotor circuit is transferred back to ac mains supply through a reactor instead of a step up transformer. The objective of the voltage-controlled technique is to increase power factor of the system and to reduce low order harmonics of the input line current. The drive system is designed and implemented using a voltage source inverter in conjunction with a boost chopper for DC link voltage, instead of a conventional drive using a 6 pulse converter or a Scherbius system. The slip power is recovered by the help of a voltage source inverter (VSI) based on a space vector pulse width modulation (SVPWM) technique. In order to keep the speed of the wound rotor induction motor constant over a certain range of operating conditions, the servo state feedback controller designed by a linear quadratic regulator (LQR) is also introduced in this paper. The overall control system is implemented on DSP, DS1104TMS320F240 controller board. The performance improvement of the proposed system is tested in comparison with the conventional Scherbius system and the modified conventional Scherbius system by a 12 pulse converter in conjunction with a chopper at steady state and at dynamic conditions. A 220 W wound motor is employed for testing. It is found that the motor speed can be controlled to be constant in the operating range of 450-1200 rpm at no load and full load. It is also found that the efficiency of the proposed system is remarkably increased since the harmonics of the input ac line current is reduced while the ac line input power factor is increased. (c) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2235 / 2242
页数:8
相关论文
共 16 条
  • [1] Speed and Power Control of a Slip Energy Recovery Drive Using Voltage-Source PWM Converter with Current Controlled Technique
    Tunyasrirut, Satean
    Kinnares, Vijit
    10TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING SYMPOSIUM, 2013, 34 : 326 - 340
  • [2] Fuzzy logic controlled inverter-chopper for high performance of slip energy recovery system
    Tunyasrirut, S
    Ngamwiwit, J
    Furuya, T
    Yamamoto, Y
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 243 - 247
  • [3] A Voltage-Controlled DSTATCOM for Power-Quality Improvement
    Kumar, Chandan
    Mishra, Mahesh K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (03) : 1499 - 1507
  • [4] A STEP-DOWN CHOPPER-CONTROLLED SLIP ENERGY RECOVERY INDUCTION-MOTOR DRIVE
    REFOUFI, L
    PILLAY, P
    HARRIS, MR
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1993, 8 (03) : 396 - 403
  • [5] Study of slip energy recovery of induction motor drive using Matlab/Simulink
    Azizi, H
    Vahedi, A
    Masoum, MAS
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 563 - 569
  • [6] A DSP-based modified slip energy recovery drive using a 12-pulse converter and shunt chopper for a speed control system of a wound rotor induction motor
    Tunyasrirut, Satean
    Ngamwiwit, Jongkol
    Kinnares, Vijit
    Furuya, Tadayoshi
    Yamamoto, Yoshiichi
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (05) : 861 - 872
  • [7] Energy Conservation and Power Quality Improvement with Voltage Controlled DSTATCOM
    Kumar, Chandan
    Mishra, Mahesh K.
    2013 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2013,
  • [8] High Performance MRAM with Spin-Transfer-Torque and Voltage-Controlled Magnetic Anisotropy Effects
    Cai, Hao
    Kang, Wang
    Wang, You
    Naviner, Lirida Alves De Barros
    Yang, Jun
    Zhao, Weisheng
    APPLIED SCIENCES-BASEL, 2017, 7 (09):
  • [9] Voltage-Controlled Quadratic Buck Converter for a DC Power Management System with Constant Current Load
    Goudarzian, Alireza
    Khosravi, Adel
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2020, 31 (01) : 153 - 164
  • [10] Computer simulation of vector controlled slip-energy recovery induction machine drives
    Soltani, J
    Mirzaei, S
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY, 2003, 27 (B4): : 737 - 750