Determination of enantiomeric purity of hyoscyamine from scopolia extract using HPLC-CD system without chiral separation

被引:0
|
作者
Kudo, K
Iwaya, K
Yomota, C
Morris, S
Saito, M
机构
[1] JASCO Inc, Easton, MD 21601 USA
[2] Natl Inst Hlth Sci, Chuo Ku, Osaka 540006, Japan
[3] JASCO Corp, Hachioji, Tokyo 1928537, Japan
来源
ENANTIOMER | 2000年 / 5卷 / 3-4期
关键词
scopolia; hyoscyamine; CD detector; circular dichroism; chiral; g-factor; EE%; enantiomeric analysis;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Enantiomeric ratio of hyoscyamine from Scopolia extract was determined by chiral HPLC-CD analysis. It was found that circular dichroism (CD) detection allowed the analysis of the sample without any special pretreatment whereas UV detection required an ammonia-ether extraction. To obtain a shorter analysis time for the determination, reversed-phase HPLC-CD analysis was applied by using a g-factor calibration curve (EE% vs. CD/UV). The analysis time was shortened from 35 to 18 min. EE% values obtained were consistent with those by chiral HPLC analysis.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 25 条
  • [21] Stereoselective separation, configuration determination, and quantification of flavanone glycosides in Citrus using chiral HPLC-UV in combination with CD spectra
    Jiang, Bingtong
    Wang, Zhaokun
    Shi, Xuejiao
    Gao, Ying
    Zhang, Jiayu
    Che, Yanyun
    ANALYTICAL METHODS, 2023, 15 (46) : 6444 - 6450
  • [22] Enantiomeric separations of four basic drugs containing N-alkyl groups by a RP-HPLC system using SBE-β-CD as chiral mobile phase additive
    Huang, Min
    Chen, Wen-Jing
    Zhou, Ying
    Feng, Ru
    Fu, Jie
    Ma, Jing-Yi
    Tan, Xiang-Shan
    He, Chi-Yu
    Zhang, Qi-Ming
    He, Wen-Yi
    Deng, Yu-Lin
    Zhang, Yu-Kui
    Zhang, Xian-Feng
    Wang, Yan
    CHINESE CHEMICAL LETTERS, 2013, 24 (09) : 840 - 844
  • [23] Enantiomeric separations of four basic drugs containing N-alkyl groups by a RP-HPLC system using SBE-β-CD as chiral mobile phase additive
    Min Huang
    Wen-Jing Chen
    Ying Zhou
    Ru Feng
    Jie Fu
    Jing-Yi Ma
    Xiang-Shan Tan
    Chi-Yu He
    Qi-Ming Zhang
    Wen-Yi He
    Yu-Lin Deng
    Yu-Kui Zhang
    Xian-Feng Zhang
    Yan Wang
    ChineseChemicalLetters, 2013, 24 (09) : 840 - 844
  • [24] Determination of the enantiomeric composition of a new insulin sensitizer in plasma samples from non-clinical and clinical investigations using chiral HPLC with electrospray tandem mass spectrometric detection
    Lausecker, B
    Fischer, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2): : 40 - 46
  • [25] Simultaneous Determination of Aegeline and Six Coumarins from Different Parts of the Plant Aegle marmelos Using UHPLC-PDA-MS and Chiral Separation of Aegeline Enantiomers Using HPLC-ToF-MS
    Avula, Bharathi
    Chittiboyina, Amar G.
    Wang, Yan-Hong
    Sagi, Satyanarayanaraju
    Raman, Vijayasankar
    Wang, Mei
    Khan, Ikhlas A.
    PLANTA MEDICA, 2016, 82 (06) : 580 - 588