Smart microrobots for mechanical cell characterization and cell convoying

被引:23
作者
Boukallel, M.
Gauthier, M.
Dauge, M.
Piat, E.
Abadie, J.
机构
[1] Robot Lab Paris LRP FRE 2507, F-92265 Fontenay Aux Roses, France
[2] Lab Automat Besancon LAB UMR CNRS, F-25000 Besancon, France
关键词
cell convoying; in vitro fertilization process; mechanical cell characterization; microrobotics;
D O I
10.1109/TBME.2007.891171
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper deals with the effective design of smart microrobots for both mechanical cell characterization and cell convoying for in vitro fertilization. The first microrobotic device was developed to evaluate oocyte mechanical behavior in order to sort oocytes. A multi-axial micro-force sensor based on a frictionless magnetic bearing was developed. The second microrobotic device presented is a cell convoying device consisting of a wireless micropusher based on magnetic actuation. As wireless capabilities are supported by this microrobotic system, no power supply connections to the micropusher are needed. Preliminary experiments have been performed regarding both cell transporting and biomechanical characterization capabilities under in vitro conditions on human oocytes so as to demonstrate the viability and effectiveness of the proposed setups.
引用
收藏
页码:1536 / 1540
页数:5
相关论文
共 16 条
[1]   High sensitive micro touch sensor with piezoelectric thin film for micro pipetting works under microscope [J].
Arai, F ;
Motoo, K ;
Fukuda, T ;
Katsuragi, T .
2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, :1352-1357
[2]  
Boukallel M, 2003, IROS 2003: PROCEEDINGS OF THE 2003 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, P1062
[3]   Modelling of a 2D magnetic cell transport system [J].
Dauge, M ;
Gauthier, M ;
Piat, E .
2005 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, 2005, :4098-4103
[4]   Positioning living cells on a high-density electrode array by negative dielectrophoresis [J].
Frénéa, M ;
Faure, SP ;
Le Pioufle, B ;
Coquet, P ;
Fujita, H .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2003, 23 (05) :597-603
[5]  
Gauthier M., 2004, Journal of Micromechatronics, V2, P87, DOI 10.1163/156856302322756450
[6]  
GAUTHIER M, 2002, P IEEE INT C INT ROB, V2, P1754
[7]  
GAUTHIER M, 2002, J EUR SYST AUTOM, V36, P1249
[8]   Control of a particular micro-macro positioning system applied to cell micromanipulation [J].
Gauthier, Michael ;
Piat, Emmanuel .
IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2006, 3 (03) :264-271
[9]   Single cell trap on a chip using in-situ microfabrication with photo-crosslinkable resin and thermal gelation [J].
Ichikawa, A ;
Arai, F ;
Maruyama, H ;
Fukuda, T ;
Katsuragi, T .
2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, :2848-2853
[10]  
KIM BK, 2003, IROSO3 OCT, P74