Association of Different Stenting Procedures with Symptomatic Thromboembolic Complications in Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms

被引:7
作者
Cai, Kefu [1 ]
Ji, Qiuhong [1 ]
Cao, Maohong [1 ]
Shen, Lihua [1 ]
Xu, Tian [1 ]
Zhang, Yunfeng [1 ]
机构
[1] Nantong Univ, Affiliated Hosp, Dept Neurol, Nantong, Peoples R China
关键词
Coil embolization; Endovascular technique; Stent-assisted coiling; Subarachnoid hemorrhage; Wide-necked aneurysm; CEREBRAL ANEURYSMS; ACUTE PERIOD; RISK-FACTORS; EMBOLIZATION; EVENTS; EXPERIENCE; PROTRUSION;
D O I
10.1016/j.wneu.2017.05.093
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: This study aimed to evaluate the association of different stenting procedures with the procedure-related complications in stent-assisted coiling (SAC) of ruptured wide-necked aneurysms. METHODS: Consecutive patients undergoing SAC of ruptured wide-necked aneurysms were retrospectively reviewed between December 2011 and June 2016. They received 1 of the 3 stenting procedures during SAC: 1) the coiling microcatheter was "jailed" outside of the stent and the coil embolization proceeded above the stent; 2) initial stent deployment followed by the coils through the stent's strut technique; or 3) the coil-then-stent technique. The effect of different stenting procedures on clinical complications and outcomes was estimated by logistic regression models. RESULTS: Of the 93 patients enrolled in this study, 11 of them (11.8%) suffered from symptomatic thromboembolic events and 10 of them (10.8%) had hemorrhagic complications. SAC with different stenting procedures (odds ratio [OR] = 4.10, 95% confidence interval [CI]: 1.20-13.97, P = 0.024) was the only independent risk factor for symptomatic thromboembolic events. The coil-then-stent technique had a higher ischemic complications rate than the other 2 stenting procedures (P = 0.023). Serum glucose (OR = 1.48, P = 0.014) and systolic blood pressure on admission (OR = 0.97, P = 0.046) were independent predictors of hemorrhagic complications during SAC. However, different stenting procedures and stent types were correlated with neither aneurysm occlusion at the end of procedure (P = 0.498 and 0.176, respectively) nor favorable outcome at discharge (P = 0.710 and 0.928, respectively). CONCLUSION: Different stenting procedures were associated with thromboembolic but not hemorrhagic complications in SAC of ruptured wide-necked aneurysms.
引用
收藏
页码:824 / 830
页数:7
相关论文
共 18 条
[1]   Stent-Assisted Coiling of Wide-Necked Aneurysms in the Setting of Acute Subarachnoid Hemorrhage: Experience in 65 Patients [J].
Amenta, Peter S. ;
Dalyai, Richard T. ;
Kung, David ;
Toporowski, Amy ;
Chandela, Sid ;
Hasan, David ;
Gonzalez, L. Fernando ;
Dumont, Aaron S. ;
Tjoumakaris, Stavropoula I. ;
Rosenwasser, Robert H. ;
Maltenfort, Mitchell G. ;
Jabbour, Pascal M. .
NEUROSURGERY, 2012, 70 (06) :1415-1429
[2]   Stent-Assisted Coil Embolization of Intracranial Aneurysms: Complications in Acutely Ruptured versus Unruptured Aneurysms [J].
Bechan, R. S. ;
Sprengers, M. E. ;
Majoie, C. B. ;
Peluso, J. P. ;
Sluzewski, M. ;
van Rooij, W. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) :502-507
[3]   Stent-Assisted Coiling in Acutely Ruptured intracranial Aneurysms: A Qualitative, Systematic Review of the Literature [J].
Bodily, K. D. ;
Cloft, H. J. ;
Lanzino, G. ;
Fiorella, D. J. ;
White, P. M. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) :1232-1236
[4]   Comparison of Stent-Assisted Coiling and Balloon-Assisted Coiling in the Treatment of Ruptured Wide-Necked Intracranial Aneurysms in the Acute Period [J].
Cai, Kefu ;
Zhang, Yunfeng ;
Shen, Lihua ;
Ni, Yaohui ;
Ji, Qiuhong .
WORLD NEUROSURGERY, 2016, 96 :316-321
[5]   Stent-Assisted Coiling of Intracranial Aneurysms Predictors of Complications, Recanalization, and Outcome in 508 Cases [J].
Chalouhi, Nohra ;
Jabbour, Pascal ;
Singhal, Saurabh ;
Drueding, Ross ;
Starke, Robert M. ;
Dalyai, Richard T. ;
Tjoumakaris, Stavropoula ;
Gonzalez, L. Fernando ;
Dumont, Aaron S. ;
Rosenwasser, Robert ;
Randazzo, Ciro G. .
STROKE, 2013, 44 (05) :1348-1353
[6]   Treatment of Ruptured Intracranial Aneurysms: Comparison of Stenting and Balloon Remodeling [J].
Chitale, Rohan ;
Chalouhi, Nohra ;
Theofanis, Thana ;
Starke, Robert M. ;
Amenta, Peter ;
Jabbour, Pascal ;
Tjoumakaris, Stavropoula ;
Dumont, Aaron S. ;
Rosenwasser, Robert H. ;
Gonzalez, L. Fernando .
NEUROSURGERY, 2013, 72 (06) :953-959
[7]   Stent-assisted coil embolization of ruptured wide-necked aneurysms in the acute period: incidence of and risk factors for periprocedural complications [J].
Chung, Joonho ;
Lim, Yong Cheol ;
Suh, Sang Hyun ;
Shim, Yu Shik ;
Kim, Yong Bae ;
Joo, Jin-Yang ;
Kim, Bum-Soo ;
Shin, Yong Sam .
JOURNAL OF NEUROSURGERY, 2014, 121 (01) :4-11
[8]   Stent-assisted coil embolization of intracranial aneurysms using the Solitaire™ AB Neurovascular Remodeling Device: initial and midterm follow-up results [J].
Clajus, Christin ;
Sychra, Vojtech ;
Strasilla, Christoph ;
Klisch, Joachim .
NEURORADIOLOGY, 2013, 55 (05) :629-638
[9]   Postprocedure ischemic events after treatment of intracranial aneurysms with Guglielmi detachable coils [J].
Derdeyn, CP ;
Cross, DT ;
Moran, CJ ;
Brown, GW ;
Pilgram, TK ;
Diringer, MN ;
Grubb, RL ;
Rich, KM ;
Chicoine, MR ;
Dacey, RG .
JOURNAL OF NEUROSURGERY, 2002, 96 (05) :837-843
[10]   Risk factors for coil protrusion into the parent artery and associated thrombo-embolic events following unruptured cerebral aneurysm embolization [J].
Ishihara, Hideaki ;
Ishihara, Shoichiro ;
Niimi, Jun ;
Neki, Hiroaki ;
Kakehi, Yoshiaki ;
Uemiya, Nahoko ;
Kohyama, Shinya ;
Yamane, Fumitaka .
INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (02) :178-183