Flow injection-chemiluminescence determination of puerarin in pharmaceutical preparations

被引:18
|
作者
Zhang, QL [1 ]
Myint, A [1 ]
Liu, LJ [1 ]
Ge, XW [1 ]
Cui, H [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
flow injection; chemiluminescence (CL); cerium(IV); rhodamine; 6G; puerafin;
D O I
10.1016/j.jpba.2004.07.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Strong chemiluminescence was observed when cerium(IV) reacted with rhodamine 6G in sulfuric acid medium in the presence of puerarin. This phenomenon has been utilized to design a sensitive and selective flow injection-chemiluminescence method for the determination of puerarin. Under the optimum conditions, the proposed procedure has a linear range between 1.3 x 10(-9) and 8.0 x 10(-7) g/mL, with a detection limit of 8.4 x 10(-10) g/mL puerarin and a relative standard deviation of 1.86% (n = 11) at 5.0 x 10(-8) g/mL puerarin. The method was successfully applied to the determination of puerarin in pharmaceutical preparations. The mechanism of this chemiluminescence reaction has been proposed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:587 / 592
页数:6
相关论文
共 50 条
  • [41] Flow injection photochemical spectrofluorimetry for the determination of carbamazepine in pharmaceutical preparations
    Huang, CB
    He, QH
    Chen, HW
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (01) : 59 - 65
  • [42] Reagentless chemiluminescence flow sensor for the determination of riboflavin in pharmaceutical preparations and human urine
    Song, ZH
    Wang, L
    ANALYST, 2001, 126 (08) : 1393 - 1398
  • [43] Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer
    Nozaki, O
    Kawamoto, H
    LUMINESCENCE, 2000, 15 (03) : 137 - 142
  • [44] Dysprosium-sensitized chemiluminescence system for the determination of enoxacin in pharmaceutical preparations and biological fluids with flow-injection sampling
    Sun, Han-wen
    Wu, Yuan-yuan
    Li, Li-qing
    DRUG TESTING AND ANALYSIS, 2009, 1 (3-4) : 128 - 134
  • [45] Determination of cysteine in a pharmaceutical formulation by flow injection analysis with a chemiluminescence detector
    Lau, CW
    Qin, XJ
    Liang, HY
    Lu, HZ
    ANALYTICA CHIMICA ACTA, 2004, 514 (01) : 45 - 49
  • [46] Flow injection-chemiluminescence determination of ascorbic acid based on luminol-ferricyanide-gold nanoparticles system
    Dong, Yong Ping
    Gao, Ting Ting
    Chu, Xiang Feng
    Chen, Jun
    Wang, Cheng Ming
    JOURNAL OF LUMINESCENCE, 2014, 154 : 350 - 355
  • [47] Quantitative Monitoring of Rutin in Human Urine by Flow Injection-Chemiluminescence Analysis
    Xin, Ladi
    Li, Yajuan
    Wu, Lingmin
    Zhao, Jingchan
    Song, Zhenghua
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2017, 64 (06) : 711 - 719
  • [48] Enzyme-embedded organic monolith sensor for flow injection-chemiluminescence
    Nozaki, O.
    Munesue, M.
    Kawamoto, H.
    LUMINESCENCE, 2006, 21 (05) : 287 - 287
  • [49] Determination of puerarin in biological samples and its application to a pharmacokinetic study by flow-injection chemiluminescence
    Yang, Ran
    Wang, Qingwen
    Zeng, Huajin
    Qin, Zao
    Li, Jianjun
    Qu, Lingbo
    LUMINESCENCE, 2011, 26 (05) : 368 - 373
  • [50] Determination of hydrochlorothiazide in pharmaceutical preparations by time resolved chemiluminescence
    Pulgarín, JAM
    Molina, AA
    Nieto, GPO
    ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) : 37 - 43