Fatigue testing of a proximal femoral hip component

被引:3
|
作者
Macdonald, W
Carlsson, LV
Gathercole, N
Jacobsson, CM
机构
[1] Univ Bath, Dept Engn & Appl Sci, Mat Res Ctr, SMS Consultants, Bath BA2 7AY, Avon, England
[2] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Orthopaed, Gothenburg, Sweden
[3] Univ Gothenburg, Inst Surg Sci, Dept Biomat Res, Gothenburg, Sweden
关键词
hip replacement; fatigue testing; femoral component; GFRE bushings; GOT implant;
D O I
10.1243/09544110360579358
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Gothenburg Osseointegrated Titanium (GOT) implant is a novel total hip replacement including a metaphyseal loading proximal femoral component fixed in the retained femoral neck. Endurance testing was performed under conditions analogous to ISO 7206-4: 1989. The cement-free implant is not fixed distally within the intramedullary canal, so distal embedding (as specified in the standard) would have been unrealistic. Instead glass-fibre-reinforced epoxy (GFRE) bushings were used to model reduced bone support mid-length at the medial cortex and distally at the lateral cortex. Such support simulated proximal bone loss, realistically reproducing the effect of osteolysis or fixation failure. Under such conditions the component survived unbroken for 10 million cycles at 3.0 kN peak load.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 50 条
  • [1] Fatigue failure of the femoral component of a cementless total hip arthroplasty
    Morgan-Hough, CVJ
    Tavakkolizadeh, A
    Purkayastha, S
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 658 - 660
  • [2] Revision total hip arthroplasty with cemented femoral component
    Nouri, Habib
    Kallel, Sofiene
    Slimane, Mohamed Hadj
    Meherzi, Mohamed Hedi
    Ouertatani, Moez
    Karray, Salahedine
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (05): : 327 - 332
  • [3] Revision total hip arthroplasty with cemented femoral component
    Habib Nouri
    Sofiene Kallel
    Mohamed Hadj Slimane
    Mohamed Hédi Meherzi
    Moez Ouertatani
    Salahedine Karray
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 327 - 332
  • [4] VEHICLE COMPONENT FATIGUE TESTING.
    Powell, D.E.
    Journal of the Society of Environmental Engineers, 1980, 19 (03): : 23 - 26
  • [5] Fatigue fracture of the femoral component in total knee replacement
    Chithartha, Karthik
    Thilak, Jai
    Sukesh, A. N.
    Theruvil, Bipin
    KNEE, 2020, 27 (05): : 1439 - 1445
  • [6] Alignment guided by computer navigation of the femoral component in hip resurfacing
    Gallart, Xavier
    Fernandez-Valencia, Jenaro A.
    Riba, Josep
    Bori, Guillem
    Garcia, Sebastian
    Carrillo, Sergio
    HIP INTERNATIONAL, 2010, 20 : S43 - S47
  • [7] Isoelastic femoral component in primary cementless total hip arthroplasty
    Salaman M. Ali
    A. Kumar
    International Orthopaedics, 2002, 26 : 243 - 246
  • [8] Fatigue fracture of the femoral component in a mobile bearing knee prosthesis
    Lemaire, Roger
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (02): : 274 - 281
  • [9] Fatigue strength testing of hip stems with statistical analysis
    Ploeg, HL
    Wevers, HW
    Wyss, UP
    Bürgi, M
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1999, 9 (04) : 243 - 263
  • [10] Fracture of the neck of a femoral component in a total hip arthroplasty: a case report
    V. Artime
    J. C. Ramos
    J. M. Fernandez-Medina
    M. C. de Luis
    L. Aguilera
    International Orthopaedics, 1997, 21 : 56 - 58