Flow injection analysis of hydrogen peroxide on copper-plated screen-printed carbon electrodes

被引:82
作者
Zen, JM [1 ]
Chung, HH [1 ]
Kumar, AS [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
D O I
10.1039/b004207m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable copper-plated screen-printed carbon electrode (CuSPE) was developed for the determination of hydrogen peroxide by flow injection analysis (FIA) at ambient temperature without deoxygenation. Cyclic voltammetry on the CuSPE in pH 7.4 phosphate buffer solution showed the growth of CuO and Cu2O. A well-defined reduction signal corresponding to the mediation of CuO and Cu2O occurred in the presence of hydrogen peroxide. The mechanistic study revealed that the reduction is a coupled-chemical reaction mechanism with the operation of pseudo-first order kinetics with respect to the concentration of Cu2O. The calculated electrochemical rate constant (k(e)) from Laviron's model is 13.7 s(-1). Systematic investigations were made to optimize the experimental parameters for hydrogen peroxide detection by FIA. With a poised potential of -0.3 V versus Ag/AgCl and a flow rate of 2 ml min(-1), the calibration curve was found to be linear up to 200 mu M hydrogen peroxide with a detection limit of 0.97 mu M (S/N = 3). The CuSPE is fairly stable for repetitive measurements.
引用
收藏
页码:1633 / 1637
页数:5
相关论文
共 41 条
[2]  
Ateya Badr G., 1981, J. Electroanal. Chem, V117, P309, DOI [10.1016/S0022-0728(81)80091-5, DOI 10.1016/S0022-0728(81)80091-5]
[3]   Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrode modified with a perfluorosulfonated ionomer film [J].
Bagel, O ;
Limoges, B ;
Schollhorn, B ;
Degrand, C .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4688-4694
[4]  
Bard A. J., 1980, ELECTROCHEMICAL METH
[5]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[6]   Electrodeposition of silver(II) oxide films [J].
Breyfogle, BE ;
Hung, CJ ;
Shumsky, MG ;
Switzer, JA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (09) :2741-2746
[7]   The redox properties of active sites and the importance of the latter in electrocatalysis at copper in base [J].
Burke, LD ;
Bruton, GM ;
Collins, JA .
ELECTROCHIMICA ACTA, 1998, 44 (8-9) :1467-1479
[8]   Electrocatalytic reduction of hydrogen peroxide at platinum microparticles dispersed in a poly(o-phenylenediamine) film [J].
Cai, LT ;
Chen, HY .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (01) :14-18
[9]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[10]  
COTTON FA, 1976, BASIC INORGANIC CHEM, P303