X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

被引:14
作者
Racz, R. [1 ]
Biri, S. [1 ]
Palinkas, J. [1 ]
Mascali, D. [2 ]
Castro, G. [2 ]
Caliri, C. [2 ]
Romano, F. P. [2 ,3 ]
Gammino, S. [2 ]
机构
[1] Hungarian Acad Sci, Inst Nucl Res Atomki, Bem Ter 18-C, H-4026 Debrecen, Hungary
[2] Inst Nazl Fis Nucl, Lab Nazl Sud, Via S Sofia 62, I-95123 Catania, Italy
[3] Ist & Beni Archeol & Monumentali, CNR, Via Biblioteca 4, I-95124 Catania, Italy
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
10.1063/1.4933085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 9 条
  • [1] Imaging of ECR plasmas with a pinhole X-ray camera
    Biri, S
    Valek, A
    Suta, T
    Takács, E
    Szabó, C
    Hudson, LT
    Radics, B
    Imrek, J
    Juhász, B
    Pálinkás, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) : 1420 - 1422
  • [2] Two-frequency heating technique at the 18 GHz electron cyclotron resonance ion source of the National Institute of Radiological Sciences
    Biri, S.
    Kitagawa, A.
    Muramatsu, M.
    Drentje, A. G.
    Racz, R.
    Yano, K.
    Kato, Y.
    Sasaki, N.
    Takasugi, W.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02)
  • [3] Status and special features of the Atomki ECR ion source
    Biri, S.
    Racz, R.
    Palinkas, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
  • [4] Imaging of ECR Plasma by Computer Simulation
    Biri, Sandor
    Racz, Richard
    Imrek, Jozsef
    Derzsi, Aranka
    Lecz, Zsolt
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (11) : 2474 - 2475
  • [5] Microwave to plasma coupling in electron cyclotron resonance and microwave ion sources (invited)
    Celona, L.
    Gammino, S.
    Ciavola, G.
    Maimone, F.
    Mascali, D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02)
  • [6] Diagnostic research of plasmas generated by a 14.5 GHz ECR ion source using Langmuir-probe
    Kenéz, L
    Biri, S
    Karácsony, J
    Valek, A
    Nakagawa, T
    Stiebing, KE
    Mironov, V
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) : 617 - 619
  • [7] 3D-full wave and kinetics numerical modelling of electron cyclotron resonance ion sources plasma: steps towards self-consistency
    Mascali, David
    Torrisi, Giuseppe
    Neri, Lorenzo
    Sorbello, Gino
    Castro, Giuseppe
    Celona, Luigi
    Gammino, Santo
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2015, 69 (01)
  • [8] ECR plasma photographs as a plasma diagnostic
    Racz, R.
    Biri, S.
    Palinkas, J.
    [J]. PLASMA SOURCES SCIENCE & TECHNOLOGY, 2011, 20 (02)
  • [9] Spatially resolved X-ray spectroscopy of an ECR plasma -: indication for evaporative cooling
    Takács, E
    Radics, B
    Szabó, CI
    Biri, S
    Hudson, LT
    Imrek, J
    Juhász, B
    Suta, T
    Valek, A
    Pálinkás, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 235 : 120 - 125