Accelerated PET kinetic maps estimation by analytic fitting method

被引:6
|
作者
Scipioni, Michele [1 ]
Giorgetti, Assuero [2 ]
Della Latta, Daniele [2 ]
Fucci, Sabrina [2 ]
Positano, Vincenzo [2 ]
Landini, Luigi [1 ,2 ]
Santarelli, Maria Filomena [2 ,3 ]
机构
[1] Univ Pisa, Dipartimento Ingn Informaz, Pisa, Italy
[2] Fdn Toscana G Monasterio, Via Moruzzi,l, I-56124 Pisa, Italy
[3] CNR, Inst Clin Physiol, Via Moruzzi,l, I-56124 Pisa, Italy
关键词
Dynamic PET; Parametric images; Kinetic modeling; Analytic fitting; Non-linear least square fitting; 18F(FDG] 4D PET; PARAMETRIC IMAGES; DIRECT RECONSTRUCTION; RIDGE-REGRESSION; LEAST-SQUARES; SIMULATION; ALGORITHM; CONSTANTS;
D O I
10.1016/j.compbiomed.2018.06.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this work, we propose and test a new approach for non-linear kinetic parameters' estimation from dynamic PET data. A technique is discussed, to derive an analytical closed-form expression of the compartmental model used for kinetic parameters' evaluation, using an auxiliary parameter set, with the aim of reducing the computational burden and speeding up the fitting of these complex mathematical expressions to noisy TACs. Two alternative algorithms based on numeric calculations are considered and compared to the new proposal. We perform a simulation study aimed at (0 assessing agreement between the proposed method and other conventional ways of implementing compartmental model fitting, and (ii) quantifying the reduction in computational time required for convergence. It results in a speed-up factor of 120 when compared to a fully numeric version, or -38, with respect to a more conventional implementation, while converging to very similar values for the estimated model parameters. The proposed method is also tested on dynamic 3D PET clinical data of four control subjects. The results obtained supported those of the simulation study, and provided input and promising perspectives for the application of the proposed technique in clinical practice.
引用
收藏
页码:221 / 235
页数:15
相关论文
共 45 条
  • [31] Development of a dose estimation code for BNCT with GPU accelerated Monte Carlo and collapsed cone Convolution method
    Lee, Chang-Min
    Lee, Hee-Seock
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (05) : 1769 - 1780
  • [32] Estimation of kinetic parameters from adiabatic calorimetric data by a hybrid Particle Swarm Optimization method
    Guo, Zi-Chao
    Chen, Li-Ping
    Chen, Wang-Hua
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 122 : 273 - 279
  • [33] Simultaneous estimation of tracer kinetic model parameters using analytical and inverse approaches with a hybrid method
    Natkunam, Kokulan
    Hai, Yang
    George, Erwin
    Lai, Choi-Hong
    Liu, Li
    INTERNATIONAL JOURNAL OF COMPUTER MATHEMATICS, 2019, 96 (12) : 2567 - 2579
  • [34] Improved simultaneous estimation of tracer kinetic models with artificial immune network based optimization method
    Liu, L.
    Ding, H.
    Huang, H. B.
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 71 - 76
  • [35] Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis
    Paul R. Territo
    Amanda A. Riley
    Brian P. McCarthy
    Gary D. Hutchins
    EJNMMI Physics, 3
  • [36] Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis
    Territo, Paul R.
    Riley, Amanda A.
    McCarthy, Brian P.
    Hutchins, Gary D.
    EJNMMI PHYSICS, 2016, 3 (01):
  • [37] Efficient and rapid estimation of the accuracy of future GRACE Follow-On Earth's gravitational field using the analytic method
    Zheng Wei
    Hsu Hou-Tse
    Zhong Min
    Yun Mei-Juan
    Zhou Xu-Hua
    Peng Bi-Bo
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2010, 53 (04): : 796 - 806
  • [38] Two-dimensional direction-of-arrival estimation method based on interpolation fitting for airborne conformal MIMO radar in a multipath environment
    Hu, Yili
    Zhao, Yongbo
    Chen, Sheng
    Niu, Ben
    DIGITAL SIGNAL PROCESSING, 2022, 122
  • [39] Heterogeneous parallel computing accelerated generalized likelihood uncertainty estimation (GLUE) method for fast hydrological model uncertainty analysis purpose
    Kan, Guangyuan
    He, Xiaoyan
    Ding, Liuqian
    Li, Jiren
    Hong, Yang
    Liang, Ke
    ENGINEERING WITH COMPUTERS, 2020, 36 (01) : 75 - 96
  • [40] Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation
    Bousse, Alexandre
    Manber, Richard
    Holman, Beverley F.
    Atkinson, David
    Arridge, Simon
    Ourselin, Sebastien
    Hutton, Brian F.
    Thielemans, Kris
    MEDICAL PHYSICS, 2017, 44 (06) : 2379 - 2390