Accelerated PET kinetic maps estimation by analytic fitting method

被引:6
|
作者
Scipioni, Michele [1 ]
Giorgetti, Assuero [2 ]
Della Latta, Daniele [2 ]
Fucci, Sabrina [2 ]
Positano, Vincenzo [2 ]
Landini, Luigi [1 ,2 ]
Santarelli, Maria Filomena [2 ,3 ]
机构
[1] Univ Pisa, Dipartimento Ingn Informaz, Pisa, Italy
[2] Fdn Toscana G Monasterio, Via Moruzzi,l, I-56124 Pisa, Italy
[3] CNR, Inst Clin Physiol, Via Moruzzi,l, I-56124 Pisa, Italy
关键词
Dynamic PET; Parametric images; Kinetic modeling; Analytic fitting; Non-linear least square fitting; 18F(FDG] 4D PET; PARAMETRIC IMAGES; DIRECT RECONSTRUCTION; RIDGE-REGRESSION; LEAST-SQUARES; SIMULATION; ALGORITHM; CONSTANTS;
D O I
10.1016/j.compbiomed.2018.06.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this work, we propose and test a new approach for non-linear kinetic parameters' estimation from dynamic PET data. A technique is discussed, to derive an analytical closed-form expression of the compartmental model used for kinetic parameters' evaluation, using an auxiliary parameter set, with the aim of reducing the computational burden and speeding up the fitting of these complex mathematical expressions to noisy TACs. Two alternative algorithms based on numeric calculations are considered and compared to the new proposal. We perform a simulation study aimed at (0 assessing agreement between the proposed method and other conventional ways of implementing compartmental model fitting, and (ii) quantifying the reduction in computational time required for convergence. It results in a speed-up factor of 120 when compared to a fully numeric version, or -38, with respect to a more conventional implementation, while converging to very similar values for the estimated model parameters. The proposed method is also tested on dynamic 3D PET clinical data of four control subjects. The results obtained supported those of the simulation study, and provided input and promising perspectives for the application of the proposed technique in clinical practice.
引用
收藏
页码:221 / 235
页数:15
相关论文
共 45 条
  • [21] Error-corrected estimation of regional kinetic parameter histograms directly from pet projections
    Polonen, Harri
    Niemi, Jari
    Ruotsalainen, Ulla
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (24) : 7573 - 7586
  • [22] Analytic Estimation Method of Forced Oscillation Amplitude Under Stochastic Continuous Disturbances
    Li, Hongyu
    Ju, Ping
    Gan, Chun
    Tang, Yufei
    Yu, Yiping
    Liu, Yilu
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (04) : 4026 - 4036
  • [23] Non-invasive kinetic modelling of PET tracers with radiometabolites using a constrained simultaneous estimation method: evaluation with 11C-SB201745
    Sari, Hasan
    Erlandsson, Kjell
    Marner, Lisbeth
    Law, Ian
    Larsson, Henrik B. W.
    Thielemans, Kris
    Ourselin, Sebastien
    Arridge, Simon
    Atkinson, David
    Hutton, Brian F.
    EJNMMI RESEARCH, 2018, 8
  • [24] PSO Method for Fitting Analytic Potential Energy Functions. Application to I-(H2O)
    Bhandari, H. N.
    Ma, X.
    Paul, A. K.
    Smith, P.
    Hase, W. L.
    JOURNAL OF CHEMICAL THEORY AND COMPUTATION, 2018, 14 (03) : 1321 - 1332
  • [25] Dynamic PET Data Generation and Analysis Software Tool for Evaluating the SNR Dependence on Kinetic Parameters Estimation
    Santarelli, Maria Filomena
    Positano, Vincenzo
    Landini, Luigi
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 204 - 207
  • [26] Estimation of kinetic parameters in dynamic FDG PET imaging based on shortened protocols: a virtual clinical study
    Reshtebar, Niloufar
    Hosseini, Seyed Abolfazl
    Zhuang, Mingzan
    Sheikhzadeh, Peyman
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 199 - 213
  • [27] A novel fast Fourier transform accelerated off-grid exhaustive search method for cryo-electron microscopy fitting
    Hoffmann, Alexandre
    Perrier, Valerie
    Grudinin, Sergei
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2017, 50 : 1036 - 1047
  • [28] Impact of the Arterial Input Function Recording Method on Kinetic Parameters in Small-Animal PET
    Napieczynska, Hanna
    Kolb, Armin
    Katiyar, Prateek
    Tonietto, Matteo
    Ud-Dean, Minhaz
    Stumm, Ramona
    Herfert, Kristina
    Calaminus, Carsten
    Pichler, Bernd J.
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (07) : 1159 - 1164
  • [29] Kinetic Analysis of Dynamic 11C-Acetate PET/CT Imaging as a Potential Method for Differentiation of Hepatocellular Carcinoma and Benign Liver Lesions
    Huo, Li
    Guo, Jinxia
    Dang, Yonghong
    Lv, Jinqiao
    Zheng, Youjing
    Li, Fang
    Xie, Qingguo
    Chen, Xiaoyuan
    THERANOSTICS, 2015, 5 (04): : 371 - 377
  • [30] The uncertainty of radius estimation in least-squares sphere-fitting, with an introduction to a new summation based method