Probable cross-corridor transmission of SARS-CoV-2 due to cross airflows and its control

被引:17
作者
Cheng, Pan [1 ]
Chen, Wenzhao [1 ]
Xiao, Shenglan [2 ]
Xue, Fan [3 ]
Wang, Qun [1 ]
Chan, Pak Wai [4 ]
You, Ruoyu [6 ]
Lin, Zhang [5 ]
Niu, Jianlei [6 ]
Li, Yuguo [1 ,7 ,8 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Hong Kong, Peoples R China
[2] Sun Yat sen Univ, Sch Publ Hlth Shenzhen, Shenzhen, Peoples R China
[3] Univ Hong Kong, Dept Real Estate & Construct, Hong Kong, Peoples R China
[4] Hong Kong Observ, Kowloon, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[6] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[7] Univ Hong Kong, Sch Publ Hlth, Hong Kong, Peoples R China
[8] Univ Hong Kong, Sch Publ Hlth, Dept Mech Engn, Hong Kong, Peoples R China
关键词
COVID-19; Aerosol transmission; Ventilation; Airflow; Quarantine hotel; SARS-CoV-2; VENTILATION; OUTBREAK; INFECTION; BUILDINGS; FLATS; HOTEL;
D O I
10.1016/j.buildenv.2022.109137
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A COVID-19 outbreak occurred in May 2020 in a public housing building in Hong Kong - Luk Chuen House, located in Lek Yuen Estate. The horizontal cluster linked to the index case' flat (flat 812) remains to be explained. Computational fluid dynamics simulations were conducted to obtain the wind-pressure coefficients of each external opening on the eighth floor of the building. The data were then used in a multi-zone airflow model to estimate the airflow rate and aerosol concentration in the flats and corridors on that floor. Apart from flat 812 and corridors, the virus-laden aerosol concentrations in flats 811, 813, 815, 817 and 819 (opposite to flat 812, across the corridor) were the highest on the eighth floor. When the doors of flats 813 and 817 were opened by 20%, the hourly-averaged aerosol concentrations in these two flats were at least four times as high as those in flats 811, 815 and 819 during the index case's home hours or the suspected exposure period of secondary cases. Thus, the flats across the corridor that were immediately downstream from flat 812 were at the highest exposure risk under a prevailing easterly wind, especially when their doors or windows that connected to the corridor were open. Given that the floorplan and dimension of Luk Chuen House are similar to those of many hotels, our findings provide a probable explanation for COVID-19 outbreaks in quarantine hotels. Positive pressure and sufficient ventilation in the corridor would help to minimise such cross-corridor infections.
引用
收藏
页数:14
相关论文
共 43 条
[31]  
Public Health Expert (PHE), 2021, AUSTR QUAR SYST FAIL
[32]  
Radio Television Hong Kong (RTHK), 2021, EXP SUSP CROSS INF Q
[33]  
Slotta D, 2021, POPULATION DISTRIBUT
[34]   In China, Students in Crowded Dormitories with a Low Ventilation Rate Have More Common Colds: Evidence for Airborne Transmission [J].
Sun, Yuexia ;
Wang, Zhigang ;
Zhang, Yufeng ;
Sundell, Jan .
PLOS ONE, 2011, 6 (11)
[35]   Effects of room furnishings and air speed on particle deposition rates indoors [J].
Thatcher, TL ;
Lai, ACK ;
Moreno-Jackson, R ;
Sextro, RG ;
Nazaroff, WW .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (11) :1811-1819
[36]  
Wang Q., 2022, J HAZARD MATER
[37]  
Warner J.O., 2021, BMJ OPIN
[38]  
Wong N., 2022, S CHINA MORNING POST
[39]   To prevent SARS-CoV-2 transmission in designated quarantine hotel for travelers: Is the ventilation system a concern? [J].
Wong, Shuk-Ching ;
Chen, Hong ;
Lung, David Christopher ;
Ho, Pak-Leung ;
Yuen, Kwok-Yung ;
Cheng, Vincent Chi-Chung .
INDOOR AIR, 2021, 31 (05) :1295-1297
[40]   Experimental analysis of driving forces and impact factors of horizontal inter-unit airborne dispersion in a residential building [J].
Wu, Yan ;
Tung, Thomas C. W. ;
Niu, Jianlei .
BUILDING AND ENVIRONMENT, 2019, 151 :88-96