Probable cross-corridor transmission of SARS-CoV-2 due to cross airflows and its control

被引:17
作者
Cheng, Pan [1 ]
Chen, Wenzhao [1 ]
Xiao, Shenglan [2 ]
Xue, Fan [3 ]
Wang, Qun [1 ]
Chan, Pak Wai [4 ]
You, Ruoyu [6 ]
Lin, Zhang [5 ]
Niu, Jianlei [6 ]
Li, Yuguo [1 ,7 ,8 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Hong Kong, Peoples R China
[2] Sun Yat sen Univ, Sch Publ Hlth Shenzhen, Shenzhen, Peoples R China
[3] Univ Hong Kong, Dept Real Estate & Construct, Hong Kong, Peoples R China
[4] Hong Kong Observ, Kowloon, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[6] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[7] Univ Hong Kong, Sch Publ Hlth, Hong Kong, Peoples R China
[8] Univ Hong Kong, Sch Publ Hlth, Dept Mech Engn, Hong Kong, Peoples R China
关键词
COVID-19; Aerosol transmission; Ventilation; Airflow; Quarantine hotel; SARS-CoV-2; VENTILATION; OUTBREAK; INFECTION; BUILDINGS; FLATS; HOTEL;
D O I
10.1016/j.buildenv.2022.109137
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A COVID-19 outbreak occurred in May 2020 in a public housing building in Hong Kong - Luk Chuen House, located in Lek Yuen Estate. The horizontal cluster linked to the index case' flat (flat 812) remains to be explained. Computational fluid dynamics simulations were conducted to obtain the wind-pressure coefficients of each external opening on the eighth floor of the building. The data were then used in a multi-zone airflow model to estimate the airflow rate and aerosol concentration in the flats and corridors on that floor. Apart from flat 812 and corridors, the virus-laden aerosol concentrations in flats 811, 813, 815, 817 and 819 (opposite to flat 812, across the corridor) were the highest on the eighth floor. When the doors of flats 813 and 817 were opened by 20%, the hourly-averaged aerosol concentrations in these two flats were at least four times as high as those in flats 811, 815 and 819 during the index case's home hours or the suspected exposure period of secondary cases. Thus, the flats across the corridor that were immediately downstream from flat 812 were at the highest exposure risk under a prevailing easterly wind, especially when their doors or windows that connected to the corridor were open. Given that the floorplan and dimension of Luk Chuen House are similar to those of many hotels, our findings provide a probable explanation for COVID-19 outbreaks in quarantine hotels. Positive pressure and sufficient ventilation in the corridor would help to minimise such cross-corridor infections.
引用
收藏
页数:14
相关论文
共 43 条
  • [1] LACK OF NOSOCOMIAL SPREAD OF VARICELLA IN A PEDIATRIC HOSPITAL WITH NEGATIVE-PRESSURE VENTILATED PATIENT ROOMS
    ANDERSON, JD
    BONNER, M
    SCHEIFELE, DW
    SCHNEIDER, BC
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1985, 6 (03) : 120 - 121
  • [2] [Anonymous], 2003, MORBIDITY MORTALITY, V52, P241
  • [3] [Anonymous], 1998, NUMERICAL DATA AIR I
  • [4] [Anonymous], 2021, CONFLUENCE
  • [5] Impact of Window Films on the Overall Energy Consumption of Existing UK Hotel Buildings
    Bahadori-Jahromi, Ali
    Rotimi, Abdulazeez
    Mylona, Anastasia
    Godfrey, Paulina
    Cook, Darren
    [J]. SUSTAINABILITY, 2017, 9 (05):
  • [6] British Broadcasting Corporation (BBC), 2021, BBC
  • [7] Cable News Network (CNN), 2021, CHINA HAS BUILT 5000
  • [8] CDC, 2021, SCI BRIEF SARS COV 2, DOI DOI 10.1126/SCI
  • [9] CityNews, 2 QUAR HOT GTA HIT C
  • [10] Effect of balconies and upper-lower vents on ventilation and indoor air quality in a wind-induced, naturally ventilated building
    Cui, D. J.
    Mak, C. M.
    Niu, J. L.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (04) : 393 - 407