MEASURED ROTORDYNAMIC AND LEAKAGE CHARACTERISTICS OF A TOOTH-ON-ROTOR LABYRINTH SEAL WITH COMPARISONS TO A TOOTH-ON-STATOR LABYRINTH SEAL AND PREDICTIONS

被引:0
作者
Arthur, Stephen P. [1 ]
Childs, Dara W. [2 ]
机构
[1] Samsung Techwin, Rotordynam Engn, Houston, TX 77079 USA
[2] Texas A&M Univ, Leland T Jordan Chair Mech Engn, Turbomachinery Lab, College Stn, TX 77843 USA
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2015, VOL 7A | 2015年
关键词
ANNULAR GAS SEALS; COEFFICIENTS; FACILITY;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Rotordynamic and leakage data are presented for a see-through tooth-on-rotor (TOR) labyrinth seal with comparisons to a see-through tooth-on-stator (TOS) labyrinth seal. Measurements for both seals are also compared to predictions from XLLaby. Both seals have identical diameter and can be considered as relatively long labyrinth seals. The TOR seal has a length-to-diameter ratio of 0.62, whereas the TOS seal is longer and has a length-to-diameter ratio of 0.75. Both seals also differ by number of teeth, tooth height, and tooth cavity length. TOR labyrinth tests were carried out at an inlet pressure of 70 bar-a (1,015 psia), pressure ratios of 0.4, 0.5, and 0.6, rotor speeds up to 20,200 rpm, a radial clearance of 0.1 mm (4 mils), and three preswirl ratios. For comparison, TOS labyrinth tests were run at identical conditions as the TOR tests but for only one positive preswirl ratio. TOR labyrinth measurements show a pronounced dependence of rotordynamic coefficients on rotor speed, especially when compared to prior documented TOS labyrinth seal tests run at a radial clearance of 0.2 mm (8mils). The TOR labyrinth cross-coupled stiffness is higher in magnitude and increases at a higher rate than that of the TOS labyrinth across all test speeds. However, the TOR labyrinth effective damping was determined to be greater due to higher measurements of direct damping. Measured leakage rates for the TOR labyrinth were approximately 5-10% less than the TOS labyrinth. XLLaby underpredicted the rotordynamic coefficients for both seals. However, as with measurements, it predicted the TOR labyrinth to have higher effective damping than the TOS labyrinth.
引用
收藏
页数:10
相关论文
共 12 条
[1]  
Arthur S.P., 2015, THESIS TEXAS A M U C
[2]  
CHILDS D, 1994, J TRIBOL-T ASME, V116, P337, DOI 10.1115/1.2927226
[3]  
Childs D., 1986, T ASME, V108, P325, DOI DOI 10.1115/1.3239907
[4]   Rotordynamic-coefficient and leakage characteristics for hole-pattern-stator annular gas seals - Measurements versus predictions [J].
Childs, DW ;
Wade, J .
JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2004, 126 (02) :326-333
[5]   EXPERIMENTAL ROTORDYNAMIC COEFFICIENT RESULTS FOR TEETH-ON-ROTOR AND TEETH-ON-STATOR LABYRINTH GAS SEALS [J].
CHILDS, DW ;
SCHARRER, JK .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1986, 108 (04) :599-604
[6]   Measurements versus predictions for the dynamic impedance of annular gas seals - Part I: Test facility and apparatus [J].
Dawson, MP ;
Childs, DW ;
Holt, CG ;
Phillips, SG .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2002, 124 (04) :958-962
[7]   EXPERIMENTAL RESULTS FOR LABYRINTH GAS SEALS WITH HONEYCOMB STATORS - COMPARISONS TO SMOOTH-STATOR SEALS AND THEORETICAL PREDICTIONS [J].
HAWKINS, L ;
CHILDS, D ;
HALE, K .
JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 1989, 111 (01) :161-168
[8]  
Kwanka K., 1997, T ASME INT GAS TURB
[9]  
Mehta N., 2012, Master Thesis
[10]   Rotordynamic coefficients for a tooth-on-stator labyrinth seal at 70 bar supply pressures: Measurements versus theory and comparisons to a hole-pattern stator seal [J].
Picardo, A ;
Childs, DW .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2005, 127 (04) :843-855