EVALUATION OF TUMOR POSITION AND PTV MARGINS USING IMAGE GUIDANCE AND RESPIRATORY GATING

被引:24
|
作者
Nelson, Christopher [1 ]
Balter, Peter
Morice, Rodolfo C. [2 ]
Bucci, Kara [3 ]
Dong, Lei
Tucker, Susan [4 ]
Vedam, Sastry
Chang, Joe Y. [3 ]
Starkschall, George
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 525, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Pulm Med, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Bioinformat & Computat Biol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 76卷 / 05期
关键词
Image-guided patient setup; Respiratory gating; 4DCT; Lung cancer; Target volume; CELL LUNG-CANCER; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; GUIDED RADIATION-THERAPY; DOSE-ESCALATION; CT SCANS; MOTION;
D O I
10.1016/j.ijrobp.2009.08.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the margins currently used to generate the planning target volume for lung tumors and to determine whether image-guided patient setup or respiratory gating is more effective in reducing uncertainties in tumor position. Methods and Materials: Lung tumors in 7 patients were contoured on serial four-dimensional computed tomography (4DCT) data sets (4-8 4DCTs/patient; 50 total) obtained throughout the course of treatment. Simulations were performed to determine the tumor position when the patient was aligned using skin marks, image-guided setup based on vertebral bodies, fiducials implanted near the tumor, and the actual tumor volume under various scenarios of respiratory gating. Results: Because of the presence of setup uncertainties, the reduction in overall margin needed to completely encompass the tumor was observed to be larger for imaged-guided patient setup than for a simple respiratory-gated treatment Without respiratory gating and image-guided patient setup, margins ranged from 0.9 cm to 3.1 cm to completely encompass the tumor. These were reduced to 0.7-1.7 cm when image-guided patient setup was simulated and further reduced with respiratory gating. Conclusions: Our results indicate that if respiratory motion management is used, it should be used in conjunction with image-guided patient setup in order to reduce the overall treatment margin effectively. (C) 2010 Elsevier Inc.
引用
收藏
页码:1578 / 1585
页数:8
相关论文
共 23 条
  • [1] Impact of Respiratory Gating Using 4-Dimensional Computed Tomography on the Dosimetry of Tumor and Normal Tissues in Patients With Thoracic Malignancies
    Vlachaki, Maria
    Castellon, Ignacio
    Leite, Carlos
    Perkins, Tania
    Ahmad, Salahuddin
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (03): : 262 - 268
  • [2] Retrospective evaluation of CTV to PTV margins using CyberKnife in patients with thoracic tumors
    Floriano, Alejandro
    Garcia, Rafael
    Moreno, Ramon
    Sanchez-Reyes, Alberto
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 59 - 72
  • [3] Respiratory Gating during Stereotactic Body Radiotherapy for Lung Cancer Reduces Tumor Position Variability
    Saito, Tetsuo
    Matsuyama, Tomohiko
    Toya, Ryo
    Fukugawa, Yoshiyuki
    Toyofuku, Takamasa
    Semba, Akiko
    Oya, Natsuo
    PLOS ONE, 2014, 9 (11):
  • [4] Performance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy
    Choun, Hyung Jin
    Kim, Jung-in
    Choi, Chang Heon
    Jung, Seongmoon
    Jin, Hyeongmin
    Wu, Hong-Gyun
    Chie, Eui Kyu
    Park, Jong Min
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (3) : 809 - 816
  • [5] Evaluation of Respiratory Gating Schemes for Cardiac SPECT Using a Population of Phantoms
    Zhang, Duo
    Ghaly, Michael
    Zhang, Qi
    Mok, Greta S. P.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] The Impact of Optimal Respiratory Gating and Image Noise on Evaluation of Intratumor Heterogeneity on 18F-FDG PET Imaging of Lung Cancer
    Grootjans, Willem
    Tixier, Florent
    van der Vos, Charlotte S.
    Vriens, Dennis
    Le Rest, Catherine C.
    Bussink, Johan
    Oyen, Wim J. G.
    de Geus-Oei, Lioe-Fee
    Visvikis, Dimitris
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (11) : 1692 - 1698
  • [7] Image-guidance technique comparison on respiratory reproducibility and dose indexes for stereotactic body radiotherapy in lung tumor
    Kanzaki, Ryuji
    Araki, Fujio
    Kawamura, Shinji
    MEDICAL DOSIMETRY, 2019, 44 (04) : 385 - 393
  • [8] Is adaptive planning necessary for patients with large tumor position displacements observed on daily image guidance during lung SBRT?
    Ma, Tianjun
    Liu, Chieh-Wen
    Ahmed, Saeed
    Yu, Naichang
    Qi, Peng
    Stephans, Kevin L.
    Videtic, Gregory M. M.
    Xia, Ping
    MEDICAL DOSIMETRY, 2022, 47 (03) : 207 - 215
  • [9] Intraindividual comparison of image quality using retrospective and prospective respiratory gating for the acquisition of thin sliced four dimensional multidetector CT of the thorax in a porcine model
    Behzadi, Cyrus
    Groth, Michael
    Henes, Frank Oliver
    Schwarz, Dorothee
    Deibele, Andre
    Begemann, Philipp G. C.
    Adam, Gerhard
    Regier, Marc
    EXPERIMENTAL LUNG RESEARCH, 2015, 41 (09) : 489 - 498
  • [10] Treatment of primary liver cancer using highly-conformal radiotherapy with kv-image guidance and respiratory control
    Law, Ada L. Y.
    Ng, Wai-Tong
    Lee, Michael C. H.
    Chan, Augustine T. S.
    Fung, Kai-Hung
    Li, Francis
    Lao, Wai-Cheung
    Lee, Anne W. M.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 (01) : 56 - 61