Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] T2 and T2* Mapping
    Welsch G.H.
    Hennig F.F.
    Krinner S.
    Trattnig S.
    Current Radiology Reports, 2 (8)
  • [32] IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density
    Ehses, Philipp
    Seiberlich, Nicole
    Ma, Dan
    Breuer, Felix A.
    Jakob, Peter M.
    Griswold, Mark A.
    Gulani, Vikas
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 71 - 81
  • [33] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [34] T1 and T2 quantification from standard turbo spin echo images
    McPhee, Kelly C.
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 2052 - 2063
  • [35] Myocardial T1 and T2 mapping in diastolic and systolic phase
    Tessa, Carlo
    Diciotti, Stefano
    Landini, Nicholas
    Lilli, Alessio
    Del Meglio, Jacopo
    Salvatori, Luca
    Giannelli, Marco
    Greiser, Andreas
    Vignali, Claudio
    Casolo, Giancarlo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (05) : 1001 - 1010
  • [36] Reproducibility of myocardial T1 and T2 relaxation time measurement using slice-interleaved T1 and T2 mapping sequences
    Bellm, Steven
    Basha, Tamer A.
    Shah, Ravi V.
    Murthy, Venkatesh L.
    Liew, Charlene
    Tang, Maxine
    Ngo, Long H.
    Manning, Warren J.
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (05) : 1159 - 1167
  • [37] Myocardial T1 and T2 Mapping: Techniques and Clinical Applications
    Kim, Pan Ki
    Hong, Yoo Jin
    Im, Dong Jin
    Suh, Young Joo
    Park, Chul Hwan
    Kim, Jin Young
    Chang, Suyon
    Lee, Hye-Jeong
    Hur, Jin
    Kim, Young Jin
    Choi, Byoung Wook
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (01) : 113 - 131
  • [38] Free-breathing T2*mapping for MR myocardial iron assessment at 3 T
    Nazarova, E. E.
    Tereshchenko, G., V
    Kupriyanov, D. A.
    Smetanina, N. S.
    Novichkova, G. A.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [39] Free-breathing T2* mapping for MR myocardial iron assessment at 3 T
    E. E. Nazarova
    G. V. Tereshchenko
    D. A. Kupriyanov
    N. S. Smetanina
    G. A. Novichkova
    European Radiology Experimental, 4
  • [40] Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
    von Knobelsdorff-Brenkenhoff, Florian
    Prothmann, Marcel
    Dieringer, Matthias A.
    Wassmuth, Ralf
    Greiser, Andreas
    Schwenke, Carsten
    Niendorf, Thoralf
    Schulz-Menger, Jeanette
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15