Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Myocardial T1, T2, T2*, and fat fraction quantification via low-rank motion-corrected cardiac MR fingerprinting
    da Cruz, Gastao Jose Lima
    Velasco, Carlos
    Lavin, Begona
    Jaubert, Olivier
    Michael Botnar, Rene
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (06) : 2757 - 2774
  • [12] Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA)
    Santini, Francesco
    Kawel-Boehm, N.
    Greiser, A.
    Bremerich, J.
    Bieri, O.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 365 - 371
  • [13] Clinical evaluation of the Multimapping technique for simultaneous myocardial T1 and T2 mapping
    Jarkman, Charlotta
    Carlhall, Carl-Johan
    Henningsson, Markus
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [14] Inversion recovery TrueFISP:: Quantification of T1, T2, and spin density
    Schmitt, P
    Griswold, MA
    Jakob, PM
    Kotas, M
    Gulani, V
    Flentje, M
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 661 - 667
  • [15] Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle
    Yon Mi Sung
    Hwanseok Yong
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [16] Measuring T2 and T1, and imaging T2 without spin echoes
    Wang, G.
    El-Sharkawy, A. M.
    Edelstein, W. A.
    Schaer, M.
    Bottomley, P. A.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 214 : 273 - 280
  • [17] Accurate, precise, simultaneous myocardial T1 and T2 mapping using a radial sequence with inversion recovery and T2 preparation
    Shao, Jiaxin
    Zhou, Ziwu
    Nguyen, Kim-Lien
    Finn, J. Paul
    Hu, Peng
    NMR IN BIOMEDICINE, 2019, 32 (11)
  • [18] Simultaneous acquisition of T1ρ and T2 quantification in knee cartilage: Repeatability and diurnal variation
    Li, Xiaojuan
    Wyatt, Cory
    Rivoire, Julien
    Han, Eric
    Chen, Weitian
    Schooler, Joseph
    Liang, Fei
    Shet, Keerthi
    Souza, Richard
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1287 - 1293
  • [19] Evaluation of myocarditis with a free-breathing three-dimensional isotropic whole-heart joint T1 and T2 mapping sequence
    Hua, Alina
    Velasco, Carlos
    Munoz, Camila
    Milotta, Giorgia
    Fotaki, Anastasia
    Bosio, Filippo
    Granlund, Inka
    Sularz, Agata
    Chiribiri, Amedeo
    Kunze, Karl P.
    Botnar, Rene
    Prieto, Claudia
    Ismail, Tevfik F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (02)
  • [20] Free-breathing myocardial T2 measurements at 1.5T
    Maelene Lohezic
    Anne Menini
    Jean-Marie Escanyé
    Pierre-Yves Marie
    Damien Mandry
    Pierre-André Vuissoz
    Jacques Felblinger
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)