Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 72 条
[51]   Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution [J].
Qi, Haikun ;
Bustin, Aurelien ;
Cruz, Gastao ;
Jaubert, Olivier ;
Chen, Huijun ;
Botnar, Rene M. ;
Prieto, Claudia .
MAGNETIC RESONANCE IMAGING, 2019, 63 :159-169
[52]   Point spread functions of the T2 decay in k-space trajectories with long echo train [J].
Qin, Qin .
MAGNETIC RESONANCE IMAGING, 2012, 30 (08) :1134-1142
[53]   T1 mapping in cardiac MRI [J].
Radenkovic, Dina ;
Weingaertner, Sebastian ;
Ricketts, Lewis ;
Moon, James C. ;
Captur, Gabriella .
HEART FAILURE REVIEWS, 2017, 22 (04) :415-430
[54]   Cardiac magnetic resonance T1 mapping. Part 2: Diagnostic potential and applications [J].
Reiter, Ursula ;
Reiter, Clemens ;
Kraeuter, Corina ;
Fuchsjaeger, Michael ;
Reiter, Gert .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 :235-247
[55]   Age and sex corrected normal reference values of T1, T2 T2*and ECV in healthy subjects at 3T CMR [J].
Roy, Clotilde ;
Slimani, Alisson ;
de Meester, Christophe ;
Amzulescu, Mihaela ;
Pasquet, Agnes ;
Vancraeynest, David ;
Vanoverschelde, Jean-Louis ;
Pouleur, Anne-Catherine ;
Gerber, Bernhard L. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
[56]   Myocardial T2*mapping: influence of noise on accuracy and precision [J].
Sandino, Christopher M. ;
Kellman, Peter ;
Arai, Andrew E. ;
Hansen, Michael S. ;
Xue, Hui .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[57]   Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA) [J].
Santini, Francesco ;
Kawel-Boehm, N. ;
Greiser, A. ;
Bremerich, J. ;
Bieri, O. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) :365-371
[58]   Accurate, precise, simultaneous myocardial T1 and T2 mapping using a radial sequence with inversion recovery and T2 preparation [J].
Shao, Jiaxin ;
Zhou, Ziwu ;
Nguyen, Kim-Lien ;
Finn, J. Paul ;
Hu, Peng .
NMR IN BIOMEDICINE, 2019, 32 (11)
[59]   Cardiac T-2* mapping: Techniques and clinical applications [J].
Triadyaksa, Pandji ;
Oudkerk, Matthijs ;
Sijens, Paul E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (05) :1340-1351
[60]   Self-Navigated Isotropic Three-Dimensional Cardiac T2 Mapping [J].
van Heeswijk, Ruud B. ;
Piccini, Davide ;
Feliciano, Helene ;
Hullin, Roger ;
Schwitter, Juerg ;
Stuber, Matthias .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) :1549-1554