Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 72 条
[1]   Joint Myocardial T1 and T2 Mapping Using a Combination of Saturation Recovery and T2-preparation [J].
Akcakaya, Mehmet ;
Weingaertner, Sebastian ;
Basha, Tamer A. ;
Roujol, Sebastien ;
Bellm, Steven ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) :888-896
[2]   On the Selection of Sampling Points for Myocardial T1 Mapping [J].
Akcakaya, Mehmet ;
Weingaertner, Sebastian ;
Roujol, Sebastien ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) :1741-1753
[3]  
Basha T., 2015, J CARDIOVASC MAGN R, P17
[4]  
Bastiaansen J, 2020, MED PHYS
[5]   Interleaved T1 and T2 Relaxation Time Mapping for Cardiac Applications [J].
Blume, Ulrike ;
Lockie, Timothy ;
Stehning, Christian ;
Sinclair, Stephen ;
Uribe, Sergio ;
Razavi, Reza ;
Schaeffter, Tobias .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) :480-487
[6]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[7]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[8]   Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping [J].
Chow, Kelvin ;
Flewitt, Jacqueline A. ;
Green, Jordin D. ;
Pagano, Joseph J. ;
Friedrich, Matthias G. ;
Thompson, Richard B. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) :2082-2095
[9]   Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging [J].
Christodoulou, Anthony G. ;
Shaw, Jaime L. ;
Nguyen, Christopher ;
Yang, Qi ;
Xie, Yibin ;
Wang, Nan ;
Li, Debiao .
NATURE BIOMEDICAL ENGINEERING, 2018, 2 (04) :215-226
[10]   Cardiac Magnetic Resonance Fingerprinting: Technical Developments and Initial Clinical Validation [J].
Cruz, G. ;
Jaubert, O. ;
Botnar, R. M. ;
Prieto, C. .
CURRENT CARDIOLOGY REPORTS, 2019, 21 (09)