Texture analysis to differentiate anterior cruciate ligament in patients after surgery with platelet-rich plasma

被引:3
作者
Alves, Allan Felipe Fattori [1 ]
de Arruda Miranda, Jose Ricardo [2 ]
de Souza, Sergio Augusto Santana [2 ]
Pereira, Ricardo Violante [1 ]
de Almeida Silvares, Paulo Roberto [1 ]
Yamashita, Seizo [1 ]
Deffune, Elenice [1 ]
de Pina, Diana Rodrigues [1 ]
机构
[1] Sao Paulo State Univ Julio de Mesquita Filho, Med Sch, Av Prof Mario Rubens Guimaraes Montenegro S-N, BR-18618687 Botucatu, SP, Brazil
[2] Sao Paulo State Univ Julio de Mesquita Filho, Inst Biosci, R Prof Dr Antonio Celso Wagner Zanin 250, BR-18618687 Botucatu, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Knee joint; Classification; Magnetic resonance imaging; Texture analysis; Machine learning; Platelet-rich plasma;
D O I
10.1186/s13018-021-02437-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Platelet-rich plasma (PRP) has been used to favor anterior cruciate ligament (ACL) healing after reconstruction surgeries. However, clinical data are still inconclusive and subjective about PRP. Thus, we propose a quantitative method to demonstrate that PRP produced morphological structure changes. Methods Thirty-four patients undergoing ACL reconstruction surgery were evaluated and divided into control group (sixteen patients) without PRP application and experiment group (eighteen patients) with intraoperative application of PRP. Magnetic resonance imaging (MRI) scans were performed 3 months after surgery. We used Matlab (R) and machine learning (ML) in Orange Canvas (R) to texture analysis (TA) features extraction. Experienced radiologists delimited the regions of interest (RoIs) in the T2-weighted images. Sixty-two texture parameters were extracted, including gray-level co-occurrence matrix and gray level run length. We used the algorithms logistic regression (LR), naive Bayes (NB), and stochastic gradient descent (SGD). Results The accuracy of the classification with NB, LR, and SGD was 83.3%, 75%, 75%, respectively. For the area under the curve, NB, LR, and SGD presented values of 91.7%, 94.4%, 75%, respectively. In clinical evaluations, the groups show similar responses in terms of improvement in pain and increase in the IKDC index (International Knee Documentation Committee) and Lysholm score indices differing only in the assessment of flexion, which presents a significant difference for the group treated with PRP. Conclusions Here, we demonstrated quantitatively that patients who received PRP presented texture changes when compared to the control group. Thus, our findings suggest that PRP interferes with morphological parameters of the ACL.
引用
收藏
页数:8
相关论文
共 36 条
  • [1] [Anonymous], 2016, Diario Oficial da Uniao
  • [2] Platelet-Rich Plasma in Tendon Models: A Systematic Review of Basic Science Literature
    Baksh, Nikolas
    Hannon, Charles P.
    Murawski, Christopher D.
    Smyth, Niall A.
    Kennedy, John G.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (03) : 596 - 607
  • [3] Formulation and Storage of Platelet-Rich Plasma Homemade Product
    Bausset, Olivier
    Giraudo, Laurent
    Veran, Julie
    Magalon, Jeremy
    Coudreuse, Jean-Marie
    Magalon, Guy
    Dubois, Christophe
    Serratrice, Nicolas
    Dignat-George, Francoise
    Sabatier, Florence
    [J]. BIORESEARCH OPEN ACCESS, 2012, 1 (03): : 115 - 123
  • [4] Comparison of Machine Learning Optimal Classification Trees With the Pediatric Emergency Care Applied Research Network Head Trauma Decision Rules
    Bertsimas, Dimitris
    Dunn, Jack
    Steele, Dale W.
    Trikalinos, Thomas A.
    Wang, Yuchen
    [J]. JAMA PEDIATRICS, 2019, 173 (07) : 648 - 656
  • [5] Platelet-Rich Plasma: A Milieu of Bioactive Factors
    Boswell, Stacie G.
    Cole, Brian J.
    Sundman, Emily A.
    Karas, Vasili
    Fortier, Lisa A.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (03) : 429 - 439
  • [6] Bottou Leon, 2012, Neural Networks: Tricks of the Trade. Second Edition: LNCS 7700, P421, DOI 10.1007/978-3-642-35289-8_25
  • [7] Femoral interference screw placement through the tibial tunnel: A radiographic evaluation of interference screw divergence angles after endoscopic anterior cruciate ligament reconstruction
    Brodie, JT
    Torpey, BM
    Donald, GD
    Bade, HA
    [J]. ARTHROSCOPY, 1996, 12 (04): : 435 - 440
  • [8] Texture analysis of medical images
    Castellano, G
    Bonilha, L
    Li, LM
    Cendes, F
    [J]. CLINICAL RADIOLOGY, 2004, 59 (12) : 1061 - 1069
  • [9] USE OF GRAY VALUE DISTRIBUTION OF RUN LENGTHS FOR TEXTURE ANALYSIS
    CHU, A
    SEHGAL, CM
    GREENLEAF, JF
    [J]. PATTERN RECOGNITION LETTERS, 1990, 11 (06) : 415 - 419
  • [10] Demsar J, KNOWLEDGE DISCOVERY