Dose and detectability for a cone-beam C-arm CT system revisited

被引:3
作者
Ganguly, Arundhuti [1 ]
Yoon, Sungwon [1 ]
Fahrig, Rebecca [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS Ctr, Palo Alto, CA 94305 USA
关键词
computerised tomography; dosimetry; IMAGE QUALITY;
D O I
10.1118/1.3397465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose) 1/2. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose)(1/3) and (dose)(1/2.8), respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.
引用
收藏
页码:2264 / 2268
页数:5
相关论文
共 7 条
[1]   CONTRAST-DETAIL-DOSE ANALYSIS OF 6 DIFFERENT COMPUTED TOMOGRAPHIC SCANNERS [J].
COHEN, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :197-203
[2]   USE OF CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY IN A COMPUTED TOMOGRAPHIC SCANNER [J].
COHEN, G ;
DIBIANCA, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :189-195
[3]   Dose and image quality for a cone-beam C-arm CT system [J].
Fahrig, Rebecca ;
Dixon, Robert ;
Payne, Thomas ;
Morin, Richard L. ;
Ganguly, Arundhuti ;
Strobel, Norbert .
MEDICAL PHYSICS, 2006, 33 (12) :4541-4550
[4]  
*INT COMM RAD UN M, 1996, 54 ICRU INT COMM RAD
[5]   NOISE POWER SPECTRUM IN COMPUTED X-RAY TOMOGRAPHY [J].
RIEDERER, SJ ;
PELC, NJ ;
CHESLER, DA .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (03) :446-454
[7]   Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT [J].
Tward, Daniel J. ;
Siewerdsen, Jeffrey H. .
MEDICAL PHYSICS, 2008, 35 (12) :5510-5529