Preparation and evaluation of packed capillary columns for the separation of nucleic acids by ion-pair reversed-phase high-performance liquid chromatography

被引:44
作者
Oberacher, H
Krajete, A
Parson, W
Huber, CG
机构
[1] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
[2] Leopold Franzens Univ, Inst Legal Med, A-6020 Innsbruck, Austria
基金
奥地利科学基金会;
关键词
ion-pair chromatography; capillary columns; poly(styrene-divinylbenzene) stationary phases; stationary phases; LC; short tandem repeats sequences; forensic analysis; oligonucleotides; DNA;
D O I
10.1016/S0021-9673(00)00731-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oligonucleotides and double stranded DNA fragments were separated in 200 mu m I.D. capillary columns packed with micropellicular, octadecylated, 2.1 mu m poly(styrene-divinylbenzene) particles by ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC). Both the length and the diameter of the connecting capillaries (150x0.020 mm I.D.) as well as the detection volume (3 nl) had to be kept to a minimum in order to maintain the high efficiency of this chromatographic separation system with peak widths at half height in the range of a few seconds. Three different types of frits. namely sintered silica particles, sintered octadecylsilica particles, and monolithic poly(styrene-divinylbenzene) (PS-DVB) frits were evaluated with respect to their influence on chromatographic performance. Best performance for the separation of oligonucleotides and long DNA fragments was observed with the PS-DVB frits, whereas the short DNA fragments were optimally resolved in columns terminated by octadecylsilica frits. The maximum loading capacity of 60x0.20 mm I.D. columns ranged from 20 fmol (7.7 ng) for a 587 base pair DNA fragment to 500 fmol (2.4 ng) for a 16-mer oligonucleotide. Lower mass- and concentration detection limits in the low femtomol and low nanomol per liter range, respectively, make capillary IP-RP-HPLC with UV absorbance detection highly attractive for the separation and characterization of minute amounts of synthetic oligonucleotides, DNA restriction fragments, and short tandem repeat sequences amplified by polymerase chain reaction. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:23 / 35
页数:13
相关论文
共 35 条
[1]   MICROCOLUMN LIQUID-CHROMATOGRAPHY OF SMALL NUCLEIC-ACID CONSTITUENTS [J].
BANKS, JF ;
NOVOTNY, MV .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :13-22
[2]   APPLICATION OF CAPILLARY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TO BIOTECHNOLOGY, WITH REFERENCE TO THE ANALYSIS OF RECOMBINANT DNA-DERIVED HUMAN GROWTH-HORMONE [J].
BATTERSBY, JE ;
GUZZETTA, AW ;
HANCOCK, WS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (02) :335-342
[3]   DEOXYNUCLEOSIDE PHOSPHORAMIDITES - A NEW CLASS OF KEY INTERMEDIATES FOR DEOXYPOLYNUCLEOTIDE SYNTHESIS [J].
BEAUCAGE, SL ;
CARUTHERS, MH .
TETRAHEDRON LETTERS, 1981, 22 (20) :1859-1862
[4]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[5]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[6]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[7]   POROUS CERAMIC BED SUPPORTS FOR FUSED-SILICA PACKED CAPILLARY COLUMNS USED IN LIQUID-CHROMATOGRAPHY [J].
CORTES, HJ ;
PFEIFFER, CD ;
RICHTER, BE ;
STEVENS, TS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (08) :446-448
[8]   PREPARATION AND EVALUATION OF DRY-PACKED CAPILLARY COLUMNS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CRESCENTINI, G ;
BRUNER, F ;
MANGANI, F ;
GUAN, YF .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1659-1662
[9]   Miniaturisation: a well-defined trend in separation and preconcentration techniques [J].
deCastro, MDL ;
GamizGracia, L .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :23-40
[10]   PERFORMANCE EVALUATION OF SLURRY-PACKED CAPILLARY COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
GLUCKMAN, JC ;
HIROSE, A ;
MCGUFFIN, VL ;
NOVOTNY, M .
CHROMATOGRAPHIA, 1983, 17 (06) :303-309