Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy

被引:77
|
作者
Liberman, L
Dershaw, DD
Rosen, PP
Morris, EA
Abramson, AF
Borgen, PV
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10021 USA
关键词
breast; biopsy; breast neoplasms; diagnosis; stereotaxis;
D O I
10.1148/radiology.206.3.9494489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether complete percutaneous removal of a malignant lesion detected at mammography ensures complete excision of the carcinoma histopathologically. MATERIALS AND METHODS: A retrospective review was performed of 135 lesions in which stereotactic biopsy was performed with a directional, vacuum biopsy instrument and an 11-gauge probe followed by mammography. Carcinoma was diagnosed at stereotactic biopsy in 51 (38%) lesions. In 15 (29%) carcinomas, the lesion seen at mammography was removed at stereotactic biopsy. Surgical findings were available for correlation with biopsy and imaging findings in all 15 cases. Mammographic and histopathologic findings were reviewed. RESULTS: Mammographic findings were calcifications in 11 lesions and a mass in four lesions. The median lesion size was 0.7 cm (range, 0.2-1.4 cm), and the median number of biopsy specimens was 15 (range, 10-22 specimens). Histopathologic findings at stereotactic biopsy were ductal carcinoma in situ in 12 lesions and infiltrating ductal carcinoma in three. Surgery revealed residual carcinoma in 11 (73%) of 15 lesions, including all three infiltrating ductal carcinomas and eight of 12 ductal carcinoma in situ lesions. CONCLUSION: Complete removal of the mammographic lesion does not ensure complete excision of the carcinoma.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 50 条
  • [31] Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position
    Jane Wang
    Ning Chien
    Hsiao-Tung Lee
    European Radiology, 2020, 30 : 6080 - 6088
  • [32] Stereotactic vacuum-assisted breast biopsy in 2874 patients -: A Multicenter study
    Kettritz, U
    Rotter, K
    Schreer, I
    Murauer, M
    Schulz-Wendtiand, R
    Peter, D
    Heywang-Köbrunner, SH
    CANCER, 2004, 100 (02) : 245 - 251
  • [33] Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position
    Wang, Jane
    Chien, Ning
    Lee, Hsiao-Tung
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 6080 - 6088
  • [34] Movement of a biopsy-site marker clip after completion of stereotactic directional vacuum-assisted breast biopsy: Case report
    Burnside, ES
    Sohlich, RE
    Sickles, EA
    RADIOLOGY, 2001, 221 (02) : 504 - 507
  • [35] Percutaneous excisional biopsy of clinically benign breast lesions with vacuum-assisted system: Comparison of three devices
    Wang, Zhi Li
    Liu, Gang
    Huang, Yan
    Wan, Wen Bo
    Li, Jun Lai
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : 725 - 730
  • [36] CLIP MIGRATION AFTER VACUUM-ASSISTED STEREOTACTIC BREAST BIOPSY: A PITFALL IN PREOPERATIVE WIRE LOCALIZATION
    Bernaerts, A.
    De Schepper, A., Jr.
    Van Dam, R.
    Pouillon, M.
    JBR-BTR, 2007, 90 (03): : 172 - 175
  • [37] Clip migration after 11-gauge vacuum-assisted stereotactic biopsy: Case report
    Philpotts, LE
    Lee, CH
    RADIOLOGY, 2002, 222 (03) : 794 - 796
  • [38] Use of Bayesian Modeling to Estimate the Sensitivity of Stereotactic Directional Vacuum-Assisted Breast Biopsy When the Gold Standard is Incomplete
    Wang, Jane
    Kuo, Wen-Hung
    Pan, Shin-Liang
    Chang, King-Jen
    Teng, Yu-Chuan
    Ting-Fang, Tiffany
    ACADEMIC RADIOLOGY, 2009, 16 (11) : 1316 - 1322
  • [39] Underestimation of Ductal Carcinoma In Situ and Invasive Ductal Carcinoma in Specimens Obtained with Stereotactic-Guided Vacuum-Assisted Biopsy
    Chan, A. L. C.
    Wong, K. H.
    Tam, K. Y.
    Man, Y. Y.
    Tang, P. Y.
    HONG KONG JOURNAL OF RADIOLOGY, 2022, 25 (04): : 284 - 292
  • [40] Lesions of uncertain malignant potential of the breast (B3) on vacuum-assisted biopsy for microcalcifications: Predictors of malignancy
    Mariscotti, Giovanna
    Durando, Manuela
    Ruggirello, Irene
    Belli, Paolo
    Caumo, Francesca
    Nori, Jacopo
    Zuiani, Chiara
    Tagliafico, Alberto
    Bicchierai, Giulia
    Romanucci, Giovanna
    Londero, Viviana
    Campanino, Pier Paolo
    Bussone, Riccardo
    Castellano, Isabella
    Mule', Antonino
    Caneva, Andrea
    Bianchi, Simonetta
    Di Loreto, Carla
    Bergamasco, Laura
    Calabrese, Massimo
    Fonio, Paolo
    Houssami, Nehmat
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130