Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy

被引:77
|
作者
Liberman, L
Dershaw, DD
Rosen, PP
Morris, EA
Abramson, AF
Borgen, PV
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10021 USA
关键词
breast; biopsy; breast neoplasms; diagnosis; stereotaxis;
D O I
10.1148/radiology.206.3.9494489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether complete percutaneous removal of a malignant lesion detected at mammography ensures complete excision of the carcinoma histopathologically. MATERIALS AND METHODS: A retrospective review was performed of 135 lesions in which stereotactic biopsy was performed with a directional, vacuum biopsy instrument and an 11-gauge probe followed by mammography. Carcinoma was diagnosed at stereotactic biopsy in 51 (38%) lesions. In 15 (29%) carcinomas, the lesion seen at mammography was removed at stereotactic biopsy. Surgical findings were available for correlation with biopsy and imaging findings in all 15 cases. Mammographic and histopathologic findings were reviewed. RESULTS: Mammographic findings were calcifications in 11 lesions and a mass in four lesions. The median lesion size was 0.7 cm (range, 0.2-1.4 cm), and the median number of biopsy specimens was 15 (range, 10-22 specimens). Histopathologic findings at stereotactic biopsy were ductal carcinoma in situ in 12 lesions and infiltrating ductal carcinoma in three. Surgery revealed residual carcinoma in 11 (73%) of 15 lesions, including all three infiltrating ductal carcinomas and eight of 12 ductal carcinoma in situ lesions. CONCLUSION: Complete removal of the mammographic lesion does not ensure complete excision of the carcinoma.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 50 条
  • [1] Papillary lesions of the breast: Evaluation with stereotactic directional vacuum-assisted biopsy
    Mercado, CL
    Hamele-Bena, D
    Singer, C
    Koenigsberg, T
    Pile-Spellman, E
    Higgins, H
    Smith, SJ
    RADIOLOGY, 2001, 221 (03) : 650 - 655
  • [2] Clip placement after stereotactic vacuum-assisted breast biopsy
    Liberman, L
    Dershaw, DD
    Morris, EA
    Abramson, AF
    Thornton, CM
    Rosen, PP
    RADIOLOGY, 1997, 205 (02) : 417 - 422
  • [3] Benign intraductal papilloma: Diagnosis and removal at stereotactic vacuum-assisted directional biopsy guided by galactography
    Guenin, MA
    RADIOLOGY, 2001, 218 (02) : 576 - 579
  • [4] Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device
    Meyer, JE
    Smith, DN
    DiPiro, PJ
    Denison, CM
    Frenna, TH
    Harvey, SC
    Ko, WD
    RADIOLOGY, 1997, 204 (02) : 575 - 576
  • [5] Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    Burbank, F
    RADIOLOGY, 1997, 202 (03) : 843 - 847
  • [6] A risk stratification algorithm for lesions of uncertain malignant potential diagnosed by vacuum-assisted breast biopsy (VABB) of mammographic microcalcifications
    Clauser, Paola
    Kapetas, Panagiotis
    Stoettinger, Alexander
    Bumberger, Alexander
    Rudas, Margaretha
    Baltzer, Pascal A. T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [7] Nonpalpable breast cancer: Percutaneous diagnosis with 11-and 8-gauge stereotactic vacuum-assisted biopsy devices
    Brem, RF
    Schoonjans, JM
    Goodman, SN
    Nolten, A
    Askin, FB
    Gatewood, OMB
    RADIOLOGY, 2001, 219 (03) : 793 - 796
  • [8] Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy
    Liberman, L
    Smolkin, JH
    Dershaw, DD
    Morris, EA
    Abramson, AF
    Rosen, PP
    RADIOLOGY, 1998, 208 (01) : 251 - 260
  • [9] The Efficacy of Stereotactic Vacuum-assisted Biopsy and Needle Localization Vacuum-assisted Biopsy for Diagnosing Breast Microcalcification
    Lee, Eung-Jik
    Oh, Se-Min
    JOURNAL OF BREAST CANCER, 2010, 13 (01) : 53 - 58
  • [10] Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies
    Burbank, F
    RADIOLOGY, 1997, 204 (01) : 153 - 156