Medium Voltage DC Power Systems on Ships: An Offline Parameter Estimation for Tuning the Controllers' Linearizing Function

被引:16
作者
Bosich, Daniele [1 ]
Sulligoi, Giorgio [1 ]
Mocanu, Elena [2 ]
Gibescu, Madeleine [2 ]
机构
[1] Univ Trieste, Dept Engn & Architecture, I-34127 Trieste, Italy
[2] Eindhoven Univ Technol, Dept Elect Engn, NL-5600 MB Eindhoven, Netherlands
关键词
Constant Power Load; DC-DC power converters; Heuristic Optimization; Linearization via State Feedback; model reduction; parameter estimation; STABILITY; FEEDBACK; LOADS;
D O I
10.1109/TEC.2017.2676618
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Future shipboard power systems using Medium Voltage Direct (MVDC) technology will be based on a widespread use of power converters for interfacing generating systems and loads with the main DC bus. Such a heavy exploitation makes the voltage control challenging in the presence of tightly controlled converters. By modeling the latter as constant power loads (CPLs), one possibility to ensure the bus voltage stability is offered by the linearizing via state feedback technique, whose aim is to regulate the generating DC-DC power converters to compensate for the destabilizing effect of the CPLs. Although this method has been shown to be effective when system parameters are perfectly known, only a partial linearization can be ensured in case of parameter mismatch, thus, jeopardizing the system stability. In order to improve the linearization, therefore, guaranteeing the voltage stability, an estimation method is proposed in this paper. To this aim, offline tests are performed to provide the input data for the estimation of model parameters. Such estimated values are subsequently used for correctly tuning the linearizing function of the DC-DC converters. Simulation results for bus voltage transients show that in this way converters become sources of stabilizing power.
引用
收藏
页码:748 / 758
页数:11
相关论文
共 26 条
[1]  
AlRashidi MR, 2010, STUD COMPUT INTELL, V302, P295
[2]   On-line fault detection of aluminium electrolytic capacitors, in step-down DC-DC converters, using input current and output voltage ripple [J].
Amaral, A. M. R. ;
Cardoso, A. J. M. .
IET POWER ELECTRONICS, 2012, 5 (03) :315-322
[3]  
[Anonymous], 2013 IEEE POW EN SOC
[4]  
[Anonymous], 2010, SAFETY B
[5]  
[Anonymous], 2015, P 2015 AEIT INT ANN
[6]  
[Anonymous], 1992, NONLINEAR SYSTEMS
[7]  
[Anonymous], 2010, 17092010 IEEE
[8]   Generation control system for improving design and stability of medium-voltage DC power systems on ships [J].
Arcidiacono, V. ;
Monti, A. ;
Sulligoi, G. .
IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2012, 2 (03) :158-167
[9]   Short-circuit current calculations for DC systems [J].
Berizzi, A ;
Silvestri, A ;
Zaninelli, D ;
Massucco, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (05) :990-997
[10]  
Bosich D., 2014, P IEEE INT EL VEH C, P1, DOI DOI 10.1109/IEVC.2014.7056226