A two-terminal fault location approach based on unsynchronized phasors

被引:0
|
作者
Dalcastagne, Andre Luis [1 ]
Noceti Filho, Sidnei [1 ]
Zurn, Hans Helmut [2 ]
Seara, Rui [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Elect Engn, Circuits & Signal Proc Lab, LINSE, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Elect Engn, Power Syst Lab, LABSPOT, BR-88040900 Florianopolis, SC, Brazil
来源
2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6 | 2006年
关键词
fault location; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the fundamentals of a two-terminal impedance-based fault location algorithm for transmission lines which works with unsynchronized phasors. The proposed approach is iterative and takes into account a distributed line model. At each iteration, the voltage magnitudes calculated from the data of the sending and remote ends are approximated by two straight lines, and the fault location estimate is then defined as the intersection point of these two lines. The process ends when the difference between two successive fault location estimates becomes smaller than a tolerance stipulated by the user. Since the search process is based on voltage magnitudes, synchronism is not required between the measurements obtained at each transmission line terminal.
引用
收藏
页码:2624 / 2630
页数:7
相关论文
共 50 条
  • [21] Accurate and comprehensive fault location algorithm for two-terminal transmission lines
    Poudineh-Ebrahimi, Farhad
    Ghazizadeh-Ahsaee, Mahdi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (19) : 4334 - 4340
  • [22] A Novel Two-terminal Asynchronous Fault Location Method Based on Exchange Traveling Wave Information in Fault Section
    Luo, Xunhua
    Wu, Jingyang
    Jia, Pengjun
    Deng, Zhiming
    2023 IEEE PES 15TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE, APPEEC, 2023,
  • [23] Gaussian Process Regression-Based Predictive Fault Location Algorithm for Three-Terminal Lines Using Two-Terminal PMUs
    Badran, Osama
    Rizk, Mohammad E. M.
    Hu, Weihao
    Abulanwar, Sayed
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (04) : 5829 - 5853
  • [24] Using of current differential protection signals for fault location on two-terminal line
    Rosolowski, Eugeniusz
    Izykowski, Jan
    Saha, Murari M.
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (05): : 9 - 13
  • [25] Two-terminal AF location scheme for multi-segment combined transmission lines using unsynchronized measurements
    Ghazizadeh-Ahsaee, Mandi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 104 : 101 - 109
  • [26] Accuracy analysis using the EMD and VMD for two-terminal transmission line fault location based on traveling wave theory
    Oliveira, A. P.
    Moreira, F. A.
    Picanco, A. F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [27] A novel two-terminal fault location approach utilizing traveling-waves for series compensated line connected to wind farms
    Mishra, Saswati
    Gupta, Shubhrata
    Yadav, Anamika
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 198
  • [28] A Novel Fault-location Method for HVDC Transmission Lines Based on the Ratio of Two-terminal Traveling Wave Frequency Difference
    Shu H.
    Yang J.
    Zhang G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (18): : 6715 - 6726
  • [29] Practical Methodology for Two-Terminal Traveling Wave-Based Fault Location Eliminating the Need for Line Parameters and Time Synchronization
    Lopes, Felipe V.
    Lima, Paulo
    Ribeiro, Joao Paulo G.
    Honorato, Tiago Rocha
    Silva, Kleber Melo
    Leite, Eduardo Jorge S., Jr.
    Neves, Washington Luiz Araujo
    Rocha, Geraldo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (06) : 2123 - 2134
  • [30] Parameter-Less Fault Locator for Double-Circuit Transmission Line Using Two-Terminal Unsynchronized Measurements
    Saber, Ahmed
    Zeineldin, H. H.
    El-Saadany, Ehab F.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (05) : 2616 - 2629