A two-terminal fault location approach based on unsynchronized phasors

被引:0
|
作者
Dalcastagne, Andre Luis [1 ]
Noceti Filho, Sidnei [1 ]
Zurn, Hans Helmut [2 ]
Seara, Rui [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Elect Engn, Circuits & Signal Proc Lab, LINSE, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Elect Engn, Power Syst Lab, LABSPOT, BR-88040900 Florianopolis, SC, Brazil
关键词
fault location; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the fundamentals of a two-terminal impedance-based fault location algorithm for transmission lines which works with unsynchronized phasors. The proposed approach is iterative and takes into account a distributed line model. At each iteration, the voltage magnitudes calculated from the data of the sending and remote ends are approximated by two straight lines, and the fault location estimate is then defined as the intersection point of these two lines. The process ends when the difference between two successive fault location estimates becomes smaller than a tolerance stipulated by the user. Since the search process is based on voltage magnitudes, synchronism is not required between the measurements obtained at each transmission line terminal.
引用
收藏
页码:2624 / 2630
页数:7
相关论文
共 50 条
  • [1] An iterative two-terminal fault-location method based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zuern, Hans Helmut
    Seara, Rui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2318 - 2329
  • [2] Unsynchronized two-terminal fault location estimation
    Novosel, D
    Hart, DG
    Udren, E
    Garitty, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 130 - 138
  • [3] A novel method for fault location based on two-terminal unsynchronized data
    Li, Xun
    Gong, Qingwu
    Ming, Ruiqing
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [4] New Fault Impedance Computations for Unsynchronized Two-Terminal Fault-Location Computations
    Yu, Chi-Shan
    Chang, Li-Ren
    Cho, Jr-Ru
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2879 - 2881
  • [5] An Unsynchronized Measurements Correction Method for Two-Terminal Fault-Location Problems
    Yu, Chi-Shan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1325 - 1333
  • [6] Real-Time Traveling-Wave-Based Fault Location Using Two-Terminal Unsynchronized Data
    Lopes, F. V.
    Silva, K. M.
    Costa, F. B.
    Neves, W. L. A.
    Fernandes, D., Jr.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1067 - 1076
  • [7] Settings-Free Traveling-Wave-Based Earth Fault Location Using Unsynchronized Two-Terminal Data
    Lopes, Felipe
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [8] Settings-Free Traveling-Wave-Based Earth Fault Location Using Unsynchronized Two-Terminal Data
    Lopes, Felipe V.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (05) : 2296 - 2298
  • [9] Fault location on two-terminal transmission lines based on voltages
    Zamora, I
    Minambres, JF
    Mazon, AJ
    ALvarezIsasi, R
    Lazaro, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) : 1 - 6
  • [10] Fault location on two-terminal transmission lines based on voltages
    Basque Country Univ, Bilbao, Spain
    IEE Proc Gener Transm Distrib, 1 (1-6):