Automatic Extraction of Three-Dimensional Thoracic Aorta Geometric Model from Phase Contrast MRI for Morphometric and Hemodynamic Characterization

被引:12
|
作者
Volonghi, Paola [1 ]
Tresoldi, Daniele [1 ]
Cadioli, Marcello [2 ]
Usuelli, Antonio M. [1 ]
Ponzini, Raffaele [3 ]
Morbiducci, Umberto [4 ]
Esposito, Antonio [5 ]
Rizzo, Giovanna [1 ]
机构
[1] CNR, Inst Mol Bioimaging & Physiol, Segrate, MI, Italy
[2] Philips Healthcare, Monza, Italy
[3] CINECA, Segrate, MI, Italy
[4] Politecn Torino, Dept Mech & Aerosp Engn, Turin, Italy
[5] Sci Inst HS Raffaele, Dept Radiol, Milan, Italy
关键词
thoracic aorta; phase contrast MRI; level set segmentation; 3D geometric model; BLOOD-FLOW PATTERNS; WALL SHEAR-STRESS; SEGMENTATION; VELOCITY; ARTERY; CT; ANEURYSMS; ACCURACY; IMPACT;
D O I
10.1002/mrm.25630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and assess a new method that automatically extracts a three-dimensional (3D) geometric model of the thoracic aorta (TA) from 3D cine phase contrast MRI (PCMRI) acquisitions. Methods: The proposed method is composed of two steps: segmentation of the TA and creation of the 3D geometric model. The segmentation algorithm, based on Level Set, was set and applied to healthy subjects acquired in three different modalities (with and without SENSE reduction factors). Accuracy was evaluated using standard quality indices. The 3D model is characterized by the vessel surface mesh and its centerline; the comparison of models obtained from the three different datasets was also carried out in terms of radius of curvature (RC) and average tortuosity (AT). Results: In all datasets, the segmentation quality indices confirmed very good agreement between manual and automatic contours (average symmetric distance < 1.44 mm, DICE Similarity Coefficient > 0.88). The 3D models extracted from the three datasets were found to be comparable, with differences of less than 10% for RC and 11% for AT. Conclusion: Our method was found effective on PCMRI data to provide a 3D geometric model of the TA, to support morphometric and hemodynamic characterization of the aorta. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:873 / 882
页数:10
相关论文
共 28 条
  • [11] Contrast-enhanced three-dimensional MR angiography of the thoracic aorta:: experiences after 118 examinations with a standard dose contrast administration and different injection protocols
    Kreitner, KF
    Kunz, RP
    Kalden, P
    Kauczor, HU
    Schmitt, S
    Kuroczynski, W
    Mohr-Kahaly, S
    Voightländer, T
    Krummenauer, F
    Laub, G
    Thelen, M
    EUROPEAN RADIOLOGY, 2001, 11 (08) : 1355 - 1363
  • [12] In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Morbiducci, Umberto
    Ponzini, Raffaele
    Rizzo, Giovanna
    Cadioli, Marcello
    Esposito, Antonio
    De Cobelli, Francesco
    Del Maschio, Alessandro
    Montevecchi, Franco Maria
    Redaelli, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (03) : 516 - 531
  • [13] Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI
    Yamashita, Shuhei
    Isoda, Haruo
    Hirano, Masaya
    Takeda, Hiroyasu
    Inagawa, Shoichi
    Takehara, Yasuo
    Alley, Marcus T.
    Markl, Michael
    Pelc, Norbert J.
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 473 - 478
  • [14] In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI
    Haruo Isoda
    Yasuhide Ohkura
    Takashi Kosugi
    Masaya Hirano
    Hiroyasu Takeda
    Hisaya Hiramatsu
    Shuhei Yamashita
    Yasuo Takehara
    Marcus T. Alley
    Roland Bammer
    Norbert J. Pelc
    Hiroki Namba
    Harumi Sakahara
    Neuroradiology, 2010, 52 : 921 - 928
  • [15] Three-dimensional multicontrast blood imaging with a single acquisition: Simultaneous non-contrast-enhanced MRA and vessel wall imaging in the thoracic aorta
    Tachikawa, Yoshihiko
    Hamano, Hiroshi
    Yoshikai, Hikaru
    Ikeda, Kento
    Maki, Yasunori
    Hirata, Kazuhide
    Takahashi, Yukihiko
    Matake, Kunishige
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 617 - 632
  • [16] Automatic Three-Dimensional Rib Centerline Extraction from CT Scans For Enhanced Visualization and Anatomical Context
    Ramakrishnan, Sowmya
    Alvino, Christopher
    Grady, Leo
    Kiraly, Atilla
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [17] Automatic Extraction of Forest Inventory Variables at the Tree Level by Using Smartphone Images to Construct a Three-Dimensional Model
    Song, Jiayin
    Huang, Qiqi
    Zhao, Yue
    Song, Wenlong
    Fan, Yiming
    Lu, Chao
    FORESTS, 2023, 14 (06):
  • [18] k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm
    Pim van Ooij
    Annetje Guédon
    Henk A. Marquering
    Joppe J. Schneiders
    Charles B. Majoie
    Ed van Bavel
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 261 - 270
  • [19] Automatic three-dimensional reconstruction and characterization of articular cartilage from high-resolution ultrasound acquisitions
    Lefebvre, F
    Graillat, N
    Chérin, E
    Berger, G
    Saïed, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) : 1369 - 1381
  • [20] In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Umberto Morbiducci
    Raffaele Ponzini
    Giovanna Rizzo
    Marcello Cadioli
    Antonio Esposito
    Francesco De Cobelli
    Alessandro Del Maschio
    Franco Maria Montevecchi
    Alberto Redaelli
    Annals of Biomedical Engineering, 2009, 37