Automatic Extraction of Three-Dimensional Thoracic Aorta Geometric Model from Phase Contrast MRI for Morphometric and Hemodynamic Characterization

被引:12
|
作者
Volonghi, Paola [1 ]
Tresoldi, Daniele [1 ]
Cadioli, Marcello [2 ]
Usuelli, Antonio M. [1 ]
Ponzini, Raffaele [3 ]
Morbiducci, Umberto [4 ]
Esposito, Antonio [5 ]
Rizzo, Giovanna [1 ]
机构
[1] CNR, Inst Mol Bioimaging & Physiol, Segrate, MI, Italy
[2] Philips Healthcare, Monza, Italy
[3] CINECA, Segrate, MI, Italy
[4] Politecn Torino, Dept Mech & Aerosp Engn, Turin, Italy
[5] Sci Inst HS Raffaele, Dept Radiol, Milan, Italy
关键词
thoracic aorta; phase contrast MRI; level set segmentation; 3D geometric model; BLOOD-FLOW PATTERNS; WALL SHEAR-STRESS; SEGMENTATION; VELOCITY; ARTERY; CT; ANEURYSMS; ACCURACY; IMPACT;
D O I
10.1002/mrm.25630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and assess a new method that automatically extracts a three-dimensional (3D) geometric model of the thoracic aorta (TA) from 3D cine phase contrast MRI (PCMRI) acquisitions. Methods: The proposed method is composed of two steps: segmentation of the TA and creation of the 3D geometric model. The segmentation algorithm, based on Level Set, was set and applied to healthy subjects acquired in three different modalities (with and without SENSE reduction factors). Accuracy was evaluated using standard quality indices. The 3D model is characterized by the vessel surface mesh and its centerline; the comparison of models obtained from the three different datasets was also carried out in terms of radius of curvature (RC) and average tortuosity (AT). Results: In all datasets, the segmentation quality indices confirmed very good agreement between manual and automatic contours (average symmetric distance < 1.44 mm, DICE Similarity Coefficient > 0.88). The 3D models extracted from the three datasets were found to be comparable, with differences of less than 10% for RC and 11% for AT. Conclusion: Our method was found effective on PCMRI data to provide a 3D geometric model of the TA, to support morphometric and hemodynamic characterization of the aorta. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:873 / 882
页数:10
相关论文
共 28 条
  • [1] Imaging of the Thoracic Aorta with Time-Resolved Three-Dimensional Phase-Contrast MRI: A Review
    Hope, Thomas A.
    Herfkens, Robert J.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2008, 20 (04) : 358 - 364
  • [2] Time-resolved three-dimensional phase-contrast MRI
    Markl, M
    Chan, FP
    Alley, MT
    Wedding, KL
    Draney, MT
    Elkins, CJ
    Parker, DW
    Wicker, R
    Taylor, CA
    Herfkens, RJ
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) : 499 - 506
  • [3] Automatic MRI Brain Tissue Extraction Algorithm Based on Three-Dimensional Gray-Scale Transformation Model
    Yang, Jinzhu
    Tan, Wenjun
    Ma, Shuang
    Sun, Qi
    Xu, Mengjia
    Chen, Nan
    Zhao, Dazhe
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (06) : 907 - 911
  • [4] Three-Dimensional Phase Contrast Angiography of the Mouse Aortic Arch Using Spiral MRI
    Janiczek, Robert L.
    Blackman, Brett R.
    Roy, R. Jack
    Meyer, Craig H.
    Acton, Scott T.
    Epstein, Frederick H.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1382 - 1390
  • [5] In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI
    Isoda, Haruo
    Ohkura, Yasuhide
    Kosugi, Takashi
    Hirano, Masaya
    Takeda, Hiroyasu
    Hiramatsu, Hisaya
    Yamashita, Shuhei
    Takehara, Yasuo
    Alley, Marcus T.
    Bammer, Roland
    Pelc, Norbert J.
    Namba, Hiroki
    Sakahara, Harumi
    NEURORADIOLOGY, 2010, 52 (10) : 921 - 928
  • [6] Three-dimensional evaluation of thoracic aorta enlargement and unfolding in hypertensive men using non-contrast computed tomography
    Craiem, D.
    Chironi, G.
    Casciaro, M. E.
    Redheuil, A.
    Mousseaux, E.
    Simon, A.
    JOURNAL OF HUMAN HYPERTENSION, 2013, 27 (08) : 504 - 509
  • [7] Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis
    Fukuyama, Atsushi
    Isoda, Haruo
    Morita, Kento
    Mori, Marika
    Watanabe, Tomoya
    Ishiguro, Kenta
    Komori, Yoshiaki
    Kosugi, Takafumi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (04) : 311 - 316
  • [8] Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI
    Ebbers, T
    Wigström, L
    Bolger, AF
    Engvall, J
    Karlsson, M
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 872 - 879
  • [9] Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI
    Petersson, Sven
    Dyverfeldt, Petter
    Sigfridsson, Andreas
    Lantz, Jonas
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1249 - 1255
  • [10] k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm
    van Ooij, Pim
    Guedon, Annetje
    Marquering, Henk A.
    Schneiders, Joppe J.
    Majoie, Charles B.
    van Bavel, Ed
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (03) : 261 - 270