Improved sensor fault detection, diagnosis and estimation for screw chillers using density-based clustering and principal component analysis

被引:82
作者
Li, Guannan [1 ]
Hu, Yunpeng [2 ,3 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Urban Construct, Wuhan, Hubei, Peoples R China
[2] Wuhan Business Univ, Dept Bldg Environm & Energy Engn, Wuhan, Hubei, Peoples R China
[3] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA 94720 USA
关键词
Density-based clustering; Fault detection; diagnosis and estimation (FDDE); Pattern recognition; Principal component analysis (PCA); Screw chillers; Sensor bias fault; AIR HANDLING UNITS; VAV SYSTEMS; OPERATING PERFORMANCE; CENTRIFUGAL CHILLERS; KNOWLEDGE DISCOVERY; ENERGY-CONSUMPTION; BUILDING SYSTEMS; MULTIPLE FAULTS; STRATEGY; PCA;
D O I
10.1016/j.enbuild.2018.05.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Since the outdoor and indoor load conditions always change continuously, it may lead to the various operation characteristics in chillers. If a single principal component analysis (PCA) model is applied to detect and diagnose sensor faults under a wide range of chiller operation conditions, the various operation characteristics may confuse the sensor fault analysis process in two aspects. One is that the single PCA model may not be sensitive enough to detect less server faults due to the inadaptable and fixed fault detection boundary; the other is that the single PCA model can hardly distinguish some new normal operation conditions from serious sensor faults since it is impossible for a training PCA model to cover all chiller operation conditions. To overcome the limitations, this study proposed an improved sensor fault detection, diagnosis and estimation (FDD&E) method combining density-based clustering with PCA. Clustering analysis, i.e., the Density-Based Spatial Clustering of Applications with Noise (DBSCAN) can automatically classify operation data into clusters and recognize the corresponding operation conditions. Instead of a single PCA model, using sub-PCA models to describe each normal operation condition improved the sensitivity and reliability of fault detection and diagnosis as well as the accuracy of sensor fault estimation. The proposed method was validated using field operation data of an existing screw chiller plant while various sensor faults of different magnitudes were introduced. Results reveal that the proposed method shows better sensor FDD&E results than conventional PCA-based sensor FDD&E method using a single PCA model. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:502 / 515
页数:14
相关论文
共 54 条
[1]  
[Anonymous], 2020, Introduction to data mining
[2]   Data-driven Fault Detection and Diagnosis for HVAC water chillers [J].
Beghi, A. ;
Brignoli, R. ;
Cecchinato, L. ;
Menegazzo, G. ;
Rampazzo, M. ;
Simmini, F. .
CONTROL ENGINEERING PRACTICE, 2016, 53 :79-91
[3]   Fault detection analysis using data mining techniques for a cluster of smart office buildings [J].
Capozzoli, Alfonso ;
Lauro, Fiorella ;
Khan, Imran .
EXPERT SYSTEMS WITH APPLICATIONS, 2015, 42 (09) :4324-4338
[4]   Fault detection, diagnosis and data recovery for a real building heating/cooling billing system [J].
Chen, Youming ;
Lan, Lili .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (05) :1015-1024
[5]   A fault detection technique for air-source heat pump water chiller/heaters [J].
Chen, Youming ;
Lan, Lili .
ENERGY AND BUILDINGS, 2009, 41 (08) :881-887
[6]  
Comstock Matthew C, 2002, ASHRAE T, V108, P819
[7]   PCA-based method of soft fault detection and identification for the ongoing commissioning of chillers [J].
Cotrufo, Nunzio ;
Zmeureanu, Radu .
ENERGY AND BUILDINGS, 2016, 130 :443-452
[8]   Comparative investigations on reference models for fault detection and diagnosis in centrifugal chiller systems [J].
Dinh Anh Tuan Tran ;
Chen, Youming ;
Jiang, Changliang .
ENERGY AND BUILDINGS, 2016, 133 :246-256
[9]   Detection and diagnosis for multiple faults in VAV systems [J].
Du, Zhimin ;
Jin, Xinqiao .
ENERGY AND BUILDINGS, 2007, 39 (08) :923-934
[10]   Fault detection and diagnosis based on improved PCA with JAA method in VAV systems [J].
Du, Zhimin ;
Jin, Xinqiao ;
Wu, Lizhou .