Energy Consumption Analysis and Energy-saving Reconstruction of New Wall of Prefabricated Single Building in Heating Season

被引:0
|
作者
Jin, Qiang [1 ]
Huang, Darong [1 ,2 ]
Deng, Zhenping [2 ]
Su, Yue [1 ]
Wu, Huadong [3 ]
Xia, Xianyu [4 ]
机构
[1] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, Coll Informat Sci & Engn, Chongqing 400074, Peoples R China
[3] Chongqing ZhikuZhizao Integrated Housing Co Ltd, Chongqing 400036, Peoples R China
[4] Chonqing Real Estate Coll, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Prefabricated single building; energy consumption analysis; thermal load; energy-saving reconstruction;
D O I
10.23919/chicc.2019.8865309
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Directing against the energy consumption analysis and energy saving reconstruction of new wall of prefabricated single building in heating season, proposing a new type of assembled building structure system, with emphasis on new wall and concrete wall, taking the engineering construction of prefabricated single building in Chongqing as an example, the difference of energy consumption between the new wall of prefabricated single building and concrete wall have been compared and analyzed based on the simulation software DeST developed by Tsinghua University. The experiment result shows that the annual energy consumption of new wall in prefabricated single building model is lower than that of the concrete model compared with ordinary aluminum alloy single glass windows and energy-saving Windows. What's more, the energy-saving rate of new wall can reach 29%, which equals 75001cwh of power or 923kg of standard coal. The average room temperature of prefabricated single building can reach 13.51 degrees C compared with concrete model which average room temperature is 11.96 degrees C. The difference of dynamic temperature between the two models can reach 2 degrees C-4 degrees C. Furthermore, the thermal load of the new wall model of the prefabricated single building is about 33.18 W/m the concrete model is about 63.1 W/m. After the energy-saving reconstruction, the energy consumption of ordinary window system is 1200kwh/m, the inert gas-plated low-e membrane hollow window system of that is 900kwh/m and the saving energy rate is about 25%.
引用
收藏
页码:6514 / 6519
页数:6
相关论文
共 50 条
  • [21] Energy-saving Performance Analysis of Distributional Building Energy System
    Cao Yanfeng
    Li Hongqiang
    Dong Wenjing
    Tang Zhihua
    Zhang Guoqiang
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [22] Building Energy-saving Technology
    Liu, Bingnan
    He, Qiong
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 469 - 472
  • [23] Building Energy-Saving Technology
    Lin, Yaolin
    Yang, Wei
    BUILDINGS, 2023, 13 (09)
  • [24] ENERGY-SAVING BUILDING DESIGN
    WALTERS, S
    MECHANICAL ENGINEERING, 1975, 97 (02) : 37 - 39
  • [25] Building energy-saving measures
    Huang, Yunfeng
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 668 - 671
  • [26] Energy Consumption Analysis of Energy Saving Retrofit of Building Envelop of New Country
    Liu, Guangjun
    Zhu, Hongmei
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 326 - 330
  • [27] Research on Energy-saving Reconstruction for Office building in Cold Area
    Xi, Hui
    Hou, Wanjun
    Sun, Fengming
    Zhang, Shengyan
    COMPUTER-AIDED DESIGN, MANUFACTURING, MODELING AND SIMULATION III, 2014, 443 : 235 - +
  • [28] Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
    He Le
    Sun He-jiang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 111 - 117
  • [29] Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
    何乐
    孙贺江
    Journal of Central South University, 2009, 16 (S1) : 111 - 117
  • [30] Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
    何乐
    孙贺江
    JournalofCentralSouthUniversityofTechnology, 2009, 16(S1) (S1) : 111 - 117