Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration

被引:120
作者
Chandrashekara, R
Mohiaddin, RH
Rueckert, D
机构
[1] Univ London Imperial Coll Sci Technol & Med, Visual Informat Proc Grp, Dept Comp, London SW7 2AZ, England
[2] Royal Brompton & Harefield NHS Trust, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
基金
英国工程与自然科学研究理事会;
关键词
cardiac motion analysis; free-form deformations; image registration; mutual information; tagged MRI;
D O I
10.1109/TMI.2004.834607
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Tagged magnetic resonance imaging (MRI) is unique in its ability to noninvasively image the motion and deformation of the heart in vivo, but one of the fundamental reasons limiting its use in the clinical environment is the absence of automated tools to derive clinically useful information from tagged MR images. In this paper, we present a novel and fully automated technique based on nonrigid image registration using multilevel free-form deformations (MFFDs) for the analysis of myocardial motion using tagged MRI. The novel aspect of our technique is its integrated nature for tag localization and deformation field reconstruction using image registration and voxel based similarity measures. To extract the motion field within the myocardium during systole we register a sequence of images taken during systole to a set of reference images taken at end-diastole, maximizing the normalized mutual information between the images. We use both short-axis and long-axis images of the heart to estimate the full four-dimensional motion field within the myocardium. We also present validation results from data acquired from twelve volunteers.
引用
收藏
页码:1245 / 1250
页数:6
相关论文
共 19 条
[1]  
*AM HEART ASS, 2002, HEART DIS STROK STAT
[2]   Coupled B-snake grids and constrained thin-plate splines for analysis of 2-D tissue deformations from tagged MRI [J].
Amini, AA ;
Chen, YS ;
Curwen, RW ;
Mani, V ;
Sun, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :344-356
[3]   Tag surface reconstruction and tracking of myocardial beads from SPAMM-MRI with parametric B-spline surfaces [J].
Amini, AA ;
Chen, Y ;
Elayyadi, M ;
Radeva, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (02) :94-103
[4]  
[Anonymous], P 4 INT C MED IM COM
[5]   HEART WALL MOTION - IMPROVED METHOD OF SPATIAL MODULATION OF MAGNETIZATION FOR MR IMAGING [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 172 (02) :349-350
[6]   Three-dimensional modeling for functional analysis of cardiac images: A review [J].
Frangi, AF ;
Niessen, WJ ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :2-25
[7]  
GUPTA SN, 1995, COMP IMAG VIS, V3, P323
[8]   Spatio-temporal tracking of myocardial deformations with a 4-D B-spline model from tagged MRI [J].
Huang, JT ;
Abendschein, D ;
Dávila-Román, VG ;
Amini, AA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :957-972
[9]  
Osman NF, 1999, MAGN RESON MED, V42, P1048, DOI 10.1002/(SICI)1522-2594(199912)42:6<1048::AID-MRM9>3.0.CO
[10]  
2-M