Safety parameter considerations of anodal transcranial Direct Current Stimulation in rats

被引:45
作者
Jackson, Mark P. [1 ,2 ]
Truong, Dennis [2 ]
Brownlow, Milene L. [1 ,3 ]
Wagner, Jessica A. [1 ]
McKinley, R. Andy [1 ]
Bikson, Marom [2 ]
Jankord, Ryan [1 ]
机构
[1] Air Force Res Lab, 711th Human Performance Wing, Wright Patterson AFB, OH 45433 USA
[2] CUNY City Coll, Dept Biomed Engn, CDI Bldg,85 St Nicholas Terrace, New York, NY 10031 USA
[3] Natl Acad Sci, Natl Res Council, Res Associateship Program, Washington, DC 20001 USA
关键词
tDCS; Rat cortex; Direct Current Stimulation; Current density; tDCS modeling; Microglia; NONINVASIVE BRAIN-STIMULATION; ELECTRICAL-STIMULATION; MOTOR CORTEX; TDCS; PHASE; PAIN; EXCITABILITY; PLASTICITY; DENSITY;
D O I
10.1016/j.bbi.2017.04.008
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
A commonly referenced transcranial Direct Current Stimulation (tDCS) safety threshold derives from tDCS lesion studies in the rat and relies on electrode current density (and related electrode charge density) to support clinical guidelines. Concerns about the role of polarity (e.g. anodal tDCS), sub-lesion threshold injury (e.g. neuroinflammatory processes), and role of electrode montage across rodent and human studies support further investigation into animal models of tDCS safety. Thirty-two anesthetized rats received anodal tDCS between 0 and 5 mA for 60 min through one of three epicranial electrode montages. Tissue damage was evaluated using hemotoxylin and eosin (H&E) staining, Iba-1 immunohistochemistry, and computational brain current density modeling. Brain lesion occurred after anodal tDCS at and above 0.5 mA using a 25.0 mm(2) electrode (electrode current density: 20.0 A/m(2)). Lesion initially occurred using smaller 10.6 mm(2) or 5.3 mm(2) electrodes at 0.25 mA (23.5 A/m(2)) and 0.5 mA (94.2 A/m(2)), respectively. Histological damage was correlated with computational brain current density predictions. Changes in microglial phenotype occurred in higher stimulation groups. Lesions were observed using anodal tDCS at an electrode current density of 20.0 A/m(2) which is below the previously reported safety threshold of 142.9 A/m(2) using cathodal tDCS. The lesion area is not simply predicted by electrode current density (and so not by charge density as duration was fixed); rather computational modeling suggests average brain current density as a better predictor for anodal tDCS. Nonetheless, under the assumption that rodent epicranial stimulation is a hypersensitive model, an electrode current density of 20.0 A/m(2) represents a conservative threshold for clinical tDCS, which typically uses an electrode current density of 2 A/m(2) when electrodes are placed on the skin (resulting in a lower brain current density). (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 53 条
[1]  
AGNEW WF, 1987, NEUROSURGERY, V20, P143
[2]   Using Transcranial Direct-Current Stimulation to Treat Stroke Patients With Aphasia [J].
Baker, Julie M. ;
Rorden, Chris ;
Fridriksson, Julius .
STROKE, 2010, 41 (06) :1229-1236
[3]  
BIKSON M, 2016, BRAIN STIMUL
[4]   Establishing safety limits for transcranial direct current stimulation [J].
Bikson, Marom ;
Datta, Abhishek ;
Elwassif, Maged .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (06) :1033-1034
[5]   Transcranial direct current stimulation (tDCS) in unipolar vs. bipolar depressive disorder [J].
Brunoni, A. R. ;
Ferrucci, R. ;
Bortolomasi, M. ;
Vergari, M. ;
Tadini, L. ;
Boggio, P. S. ;
Giacopuzzi, M. ;
Barbieri, S. ;
Priori, A. .
PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 2011, 35 (01) :96-101
[6]  
Brunoni Andre R, 2013, Front Psychiatry, V4, P19, DOI 10.3389/fpsyt.2013.00019
[7]   Working memory improvement with non-invasive brain stimulation of the dorsolateral prefrontal cortex: A systematic review and meta-analysis [J].
Brunoni, Andre Russowsky ;
Vanderhasselt, Marie-Anne .
BRAIN AND COGNITION, 2014, 86 :1-9
[8]   Clinical research with transcranial direct current stimulation (tDCS): Challenges and future directions [J].
Brunoni, Andre Russowsky ;
Nitsche, Michael A. ;
Bolognini, Nadia ;
Bikson, Marom ;
Wagner, Tim ;
Merabet, Lotfi ;
Edwards, Dylan J. ;
Valero-Cabre, Antoni ;
Rotenberg, Alexander ;
Pascual-Leone, Alvaro ;
Ferrucci, Roberta ;
Priori, Alberto ;
Boggio, Paulo Sergio ;
Fregni, Felipe .
BRAIN STIMULATION, 2012, 5 (03) :175-195
[9]   Clinically Effective Treatment of Fibromyalgia Pain With High-Definition Transcranial Direct Current Stimulation: Phase II Open-Label Dose Optimization [J].
Castillo-Saavedra, Laura ;
Gebodh, Nigel ;
Bikson, Marom ;
Diaz-Cruz, Camilo ;
Brandao, Rivail ;
Coutinho, Livia ;
Truong, Dennis ;
Datta, Abhishek ;
Shani-Hershkovich, Revital ;
Weiss, Michal ;
Laufer, Ilan ;
Reches, Amit ;
Peremen, Ziv ;
Geva, Amir ;
Parra, Lucas C. ;
Fregni, Felipe .
JOURNAL OF PAIN, 2016, 17 (01) :14-26
[10]   tDCS-Induced Analgesia and Electrical Fields in Pain-Related Neural Networks in Chronic Migraine [J].
DaSilva, Alexandre F. ;
Mendonca, Mariana E. ;
Zaghi, Soroush ;
Lopes, Mariana ;
DosSantos, Marcos Fabio ;
Spierings, Egilius L. ;
Bajwa, Zahid ;
Datta, Abhishek ;
Bikson, Marom ;
Fregni, Felipe .
HEADACHE, 2012, 52 (08) :1283-1295