Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography

被引:6
作者
Fu Jing [1 ]
Li Shu-ning [1 ]
Wang Xiao-zhen [1 ]
Wu Ge-wei [2 ]
Mu Da-peng [1 ]
Wang Jian [3 ]
Wang Ning-li [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Beijing Shijingshan Hosp, Dept Ophthalmol, Beijing 100038, Peoples R China
[3] Capital Med Univ, Dept Ophthalmol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
关键词
rotating scheimpflug camera; anterior segment optical coherence tomography; anterior chamber volume; CORNEAL THICKNESS MEASUREMENT; ACCOMMODATION; REPEATABILITY; DIMENSIONS; ULTRASOUND; PENTACAM;
D O I
10.3760/cma.j.issn.0366-6999.2010.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT). Methods Thirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT. Results Good repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 mu l and 95% Cl for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 mu l). Conclusions Both RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT Chin Med J 2010;123(2):203-207
引用
收藏
页码:203 / 207
页数:5
相关论文
共 50 条
[41]   The Reliability of Successive Scheimpflug Imaging and Anterior Segment Optical Coherence Tomography Measurements Decreases With Increasing Keratoconus Severity [J].
Flockerzi, Elias ;
Elzer, Berit ;
Daas, Loay ;
Xanthopoulou, Kassandra ;
Eppig, Timo ;
Langenbucher, Achim ;
Seitz, Berthold .
CORNEA, 2021, 40 (11) :1433-1439
[42]   Corneal Thickness and Volume Measurements by Swept Source Anterior Segment Optical Coherence Tomography in Normal Subjects [J].
Fukuda, Reina ;
Usui, Tomohiko ;
Miyai, Takashi ;
Mori, Yosai ;
Miyata, Kazunori ;
Amano, Shiro .
CURRENT EYE RESEARCH, 2013, 38 (05) :531-536
[43]   Agreement in anterior segment measurements between swept-source optical coherence and dual Scheimpflug tomography devices in keratoconus eyes [J].
Lee, Yunjin ;
Oh, Joo Youn ;
Choi, Hyuk Jin ;
Kim, Mee Kum ;
Yoon, Chang Ho .
SCIENTIFIC REPORTS, 2024, 14 (01)
[44]   Anterior Segment Optical Coherence Tomography Angiography and Optical Coherence Tomography in the Evaluation of Episcleritis and Scleritis [J].
Hau, Scott C. ;
Devarajan, Kavya ;
Ang, Marcus .
OCULAR IMMUNOLOGY AND INFLAMMATION, 2021, 29 (02) :362-369
[45]   Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth [J].
Huang, Jinhai ;
Lu, Weicong ;
Savini, Giacomo ;
Chen, Hao ;
Wang, Chengfang ;
Yu, Xinxin ;
Bao, Fangjun ;
Wang, Qinmei .
JOURNAL OF OPHTHALMOLOGY, 2016, 2016
[46]   Serial Analysis of Anterior Chamber Depth and Angle Status Using Anterior Segment Optical Coherence Tomography After Boston Keratoprosthesis [J].
Kang, Joann J. ;
Allemann, Norma ;
de la Cruz, Jose ;
Cortina, Maria Soledad .
CORNEA, 2013, 32 (10) :1369-1374
[47]   Effect of Lateral Decubitus Body Posture on Anterior Chamber Angle in Healthy Subjects: An Anterior Segment Optical Coherence Tomography Study [J].
Park, Ji-Hye ;
Yeon, Dong Yun ;
Yoo, Chungkwon ;
Kim, Yong Yeon .
JOURNAL OF GLAUCOMA, 2017, 26 (07) :608-612
[48]   Qualitative evaluation of anterior segment in angle closure disease using anterior segment optical coherence tomography [J].
Moghimi, Sasan ;
Chen, Rebecca ;
Hamzeh, Nikoo ;
Khatibi, Nassim ;
Lin, Shan C. .
JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04) :170-175
[49]   Comparison of Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography for Imaging of Anterior Segment Tumors [J].
Bianciotto, C. G. ;
Romanelli, M. ;
Guzman, M. ;
Mazzuca, D. ;
Green, R. ;
Shields, C. L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
[50]   Anterior segment optical coherence tomography in Terrien marginal degeneration [J].
Goel, Neha ;
Shukla, Gaurav ;
Mehta, Aanchal ;
Batra, Jyoti .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) :1695-1696