Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography

被引:6
作者
Fu Jing [1 ]
Li Shu-ning [1 ]
Wang Xiao-zhen [1 ]
Wu Ge-wei [2 ]
Mu Da-peng [1 ]
Wang Jian [3 ]
Wang Ning-li [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Beijing Shijingshan Hosp, Dept Ophthalmol, Beijing 100038, Peoples R China
[3] Capital Med Univ, Dept Ophthalmol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
关键词
rotating scheimpflug camera; anterior segment optical coherence tomography; anterior chamber volume; CORNEAL THICKNESS MEASUREMENT; ACCOMMODATION; REPEATABILITY; DIMENSIONS; ULTRASOUND; PENTACAM;
D O I
10.3760/cma.j.issn.0366-6999.2010.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT). Methods Thirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT. Results Good repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 mu l and 95% Cl for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 mu l). Conclusions Both RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT Chin Med J 2010;123(2):203-207
引用
收藏
页码:203 / 207
页数:5
相关论文
共 50 条
  • [21] Comparison of Anterior Segment Measurements between Scheimpflug-Placido Camera and New Swept-source Optical Coherence Tomography
    Choe, Gon Soo
    Kim, Kook Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (01): : 10 - 19
  • [22] Anterior Segment Optical Coherence Tomography for Canaliculitis
    Yoon, Sumin
    Lee, Hyunkyu
    Baek, Sehyun
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (01) : E59 - E61
  • [23] Inter-changeability Between Anterior Segment Optical Coherence Tomography and Scheimpflug Imaging in the Evaluation of Corneal Opacity
    Mounir, Amr
    Abdellah, Marwa Mahmoud
    Zidan, Omar Fawzy
    Mostafa, Engy Mohamed
    OPEN OPHTHALMOLOGY JOURNAL, 2022, 16
  • [24] Comparison of anterior segment measurements with optical low-coherence reflectometry and rotating dual Scheimpflug analysis
    Huerva, Valentin
    Ascaso, Francisco J.
    Soldevila, Jordi
    Lavilla, Laura
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) : 1170 - 1176
  • [25] Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series
    Vercauteren, Leonie
    Consejo, Alejandra
    De Vries, Meindert Jan
    Krolo, Iva
    Koppen, Carina
    Dhubhghaill, Sorcha Ni
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07): : 321 - 328
  • [26] A study of mydriatic effect on intraocular pressure and anterior chamber angle morphology by anterior segment optical coherence tomography
    Prabhakar, Srinivasapuram Krishnacharya
    Hiremath, Meghana
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (02) : 93 - 99
  • [27] Corneal Tomography in a Commercially Available Optical Coherence Tomography Device and Comparison With a Rotating Scheimpflug Camera
    Kanclerz, Piotr
    Radomski, Szymon Adam
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (03): : 138 - 144
  • [28] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [29] Measurement of the Lower Lid Margin Thickness by Anterior Segment Optical Coherence Tomography
    Wang, Da-Hu
    Li, Zhao-Yan
    Liu, Xin-Quan
    OPHTHALMIC RESEARCH, 2021, 64 (01) : 22 - 27
  • [30] Morphometric Measurement of Pterygium with Anterior Segment Optical Coherence Tomography and Relationship with Astigmatism
    Yoon, Sumin
    Na, Miri
    Eom, Youngsub
    Kim, Hyo Myung
    Song, Jong Suk
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (08): : 653 - 659